Wednesday, 6 February 2019

AIWA NSX-SZ70 - CIRCUIT DIAGRAM – HOW TO RESET - COMPACT DISC STEREO CASSETTE RECEIVER

Circuit Diagram – How to Reset - Aiwa NSX-SZ70 COMPACT DISC STEREO CASSETTE RECEIVER


Aiwa NSX-SZ70 - NSX-SZ73 - COMPACT DISC STEREO CASSETTE RECEIVER
BASIC TAPE MECHANISM: 2ZM-3MK2 PR4NM  
BASIC CD MECHANISM: AZG-1 ZD3RDM


RESET
There are cases that the machine does not work correctly because the MICROCOMPUTER is not reset even though the AC power cord is re-inserted, or the software reset (pressing the STOP key + POWER key) is performed.  When the above described phenomenon occurs, it can lead to wrong judgement as if the MICROCOMPUTER is defective and to exchange the MICROCOMPUTER. In such a case, perform the forced-reset by the following procedure and check good or no good of the MICROCOMPUTER.
1 Remove the AC power cord.
2 Short both ends of the electrolytic capacitor C113 that is connected to VDD of the MICROCOMPUTER with tweezers.
3 Connect the AC power cord again. If the MICROCOMPUTER returns to the normal operation, the MICROCOMPUTER is good.
Note: The reference number or MICROCOMPUTER pin number of transistor (Q110) and electrolytic capacitor (C113) can change depending on the models. Be sure to check the reference numbers on schematic diagram before starting the discharging work.
BEFORE STARTING REPAIR
Forced discharge of electrolytic capacitor of power supply block
When repair is going to be attempted in the set that uses relay circuit in the power supply block, electric potential is kept charged across the electrolytic capacitors (C101, 102) even though AC power cord is removed. If repair is attempted in this condition, secondary defect can occur.  In order to prevent the secondary trouble, perform the following measures before starting repair work.
Discharge procedure
1 Remove the AC power cord.
2 Connect a discharging resistor at an end of lead wire that has clips at both ends. Connect the other end of the lead wire to metal chassis.
3 Contact the other end of the discharging resistor to the positive (+) side (+VH) of C101. (For two seconds)
4 Contact the same end of the discharging resistor as step
3 to the negative (-) side (-VH) of C102 in the same way. (For two seconds)
5 Check that voltage across C101 and C102 has decreased to 1 V or less using a multimeter or an oscilloscope.
[reference numbers (C101, C102) of the electrolytic capacitors can change depending on the models. Be sure to check the reference numbers of the charging capacitors on schematic diagram before starting the discharging work.]
Circuit Diagram
Power Supply and power amplifier
Pre-amplifier - Front panel
Front panel - Head Pre -Tuner
The Check items before exchanging the MICROCOMPUTER
Be sure to check the following items before exchanging the MICROCOMPUTER. Exchange the MICROCOMPUTER after confirming that the MICROCOMPUTER is surely defective.
Regarding the HOLD terminal of the MICROCOMPUTER
When the HOLD terminal (INPUT) of the MICROCOMPUTER is “H”, the MICROCOMPUTER is judged to be operating correctly.
When this terminal is “L”, the main power cannot be turned on. Therefore, be sure to check the terminal voltage of the HOLD terminal before exchange.
When the MICROCOMPUTER is not defective, the HOLD terminal can also go “L” when the POWER AMPLIFIER has any abnormalities that triggers the abnormality detection circuit on the MAIN C. B. that sets the HOLD terminal to “L”.
Good or no good judgment of the MICROCOMPUTER
1 Turn on the AC main power.
2 Confirm that the main power is turned on and the HOLD terminal of the MICROCOMPUTER keeps the “H” level or not.
3 When the HOLD terminal is “L” level, the abnormality detection circuit is judged to be working correctly and the MICROCOMPUTER is judged to be good.