TOSHIBA - LCD - AD194TW_ DISASSEMBLE PROCEDURE




  • Disassemble the fixed four screws of stand.  Remove the base and stand following the direction of arrowhead showed. 

  • Disassemble the fixed 4 screws of the back cover.
  • Insert a plastic card or abandoned IC card in the bottom of the monitor, between bezel and back cover, and remove the back cover.



  • Disassemble the two screws and 3 connects pins of KEPC board.


  • Disassemble 2 screws and 4 pins that fix the shield, and remove the shield the direction of arrowhead.




  • Disassemble connect pins of the main board to panel.


  • Remove the bezel.
  • Disassemble screws that fix the panel.  That's all. Process is over.