Wednesday, 20 March 2019

FUJITSU P42HCA30 - VS & VA ADJUSTMENT

FUJITSU P42HCA30 - Vs & Va ADJUSTMENT



When main power supply PCB or PDP panel is replaced, Vs and Va voltages should be adjusted.


  • Preparation : Within 3 minutes after power on.
  • Adjustment : Adjust the VSand VAin the no-signal state.
  • Check points : Refer to the drawing shown below.
  • Adjustment points : Refer to the drawing shown below.
  • Adjustment value : Within +/- 0.2V of voltage indicated on the label of the PDP panel.