Saturday, 30 March 2019

GRUNDIG LENARO – SEDANCE – VIVANCE – HOW TO ENTER SERVICE MODE – SMPS SCHEMATIC

GRUNDIG LENARO – SEDANCE – VIVANCE – HOW TO ENTER SERVICE MODE – SMPS SCHEMATIC


Lenaro 26 LXW 68-7731 IDTV GBG4500 / GBG4600  _ SEDANCE 26 LXW 68-6631 IDTV GBG5600 / GBG5700 _ Vivance 32-6731 DVB-T GBG3600 / GBG3700 
SERVICE MODE
Calling up the Service Mode
* Press button " i " (INFO).
* Enter the code number "8500".
To Exit the Service Mode
* Press button "TXT".
Functions of the buttons
          Call up the Dialog Center / close down the Menu
P+/P–  Call up the dialogue line (point of menu)
◄/►    Call up the Menus / Changing the settings
TXT   Exit the Service Mode
Software Version Number
The software version number is shown on the upper part of the service menu, e.g:
SLM. 512G 02 T07
11/08/06 11: 08: 59
G: SLM. 064 04 T00
Program Search
* Press button " i " (MAIN MENU).
* Select "Setup" with the buttons P+ / P– and confirm with button "OK".
* Select "Auto-program" with the buttons P+/ P– and confirm with button "OK".
* Select the required Country with the buttons P+/ P–, ◄/► and confirm with button "OK".
[The auto program system stops at every station of acceptable reception quality (AFC and coincidence) and stores the station data and the respective standard automatically. The system then continues searching.]
*Pressing the " i " button stops the program search.
Hotel Mode
Maximum volume is limited and there is no access to "Program Table" and "Setup" at activated hotel mode.
Call up: " i " > "8500" > P+/ P– "OPTION 1" >  > P+/ P– "HOTEL" > ◄/   "YES".
Maximum volume: " i " > "8500" > P+ / P– "OPTION 1" > > P+ / P– "HOTEL VOL" > ◄/ Value 0…63.
Special Functions at activated Hotel Mode
The maximum volume can be adjusted in the additionally menu item "Maxvol" in the sound menu.
In addition there is access to the menus "Preset List" and "Channel Settings" until the set is switched off (standby).
Call up: "i" > "4658"
Display
If no picture is visible because of a wrong panel is adjusted, you can change the setting by "blind" adjust.
The following sequence of operating steps must be repeated until the picture is shown on the panel.
Call up: " i " > "8500" >  > " P– " 5 times > > "TXT" > switch set off and on.
If the picture is visible, then repeat the sequence once again and thereby adjust the correct type of panel (according to display label).
SMPS SCHEMATIC {Grundig & Beko}
CLICK ON THE PICTURES TO MAGNIFY