PANASONIC PT LC50U - PT LC50E - PT LC150 - LCD PROJECTOR - OPTICAL UNIT DISASSEMBLE METHOD
PANASONIC PT LC50U - PT LC50E - PT LC150 - LCD PROJECTOR - OPTICAL UNIT DISASSEMBLE METHOD
OPTICAL UNIT DISASSEMBLEY
- Remove 3 screws (A) to remove the Polarizer Red Unit, the
Polarizer Green unit and the Polarizer Blue Unit as shown.
- Take extreme care not to damage the Polarizer Units, when
servicing.
- Make sure that no dust gets on the Polarizer Units.
Clean the Polarizer Units with cleaning paper moistened with lens cleaner if
necessary.
- After replacing the Polarizer Unit, adjustment is necessary.
- Make sure of the Mark color to distinguish the Polarizer
Unit (Red, Green, Blue) as shown.
- Remove a screw (B) as shown. Remove the Lamp Duct.
- Remove 2 screws (C) as shown in Fig.
- Remove the Fuse Holder.
- Lift the Lamp House Unit up to release 2 projections.
- After Installing the Lamp House Unit, install the
Temperature Fuse and Fuse Holder in the original position as shown in Fig.
- Remove 2 screws (D) as shown in Fig. 4-4-5.
- Detach 2 tapes which is fixing the cable of the Temperature
Fuse.
- Remove the Duct Blue Unit carefully.