Thursday, 21 March 2019

PIONEER PDP-42A3HD - PDP-4214HD - FAULTS & SYMPTOMS

 PIONEER PDP-42A3HD - PDP-4214HD - FAULTS & SYMPTOMS


                                              
                                           

TYPICAL SYMPTOM ARE ONLY SHOWN.  ANOTHER SYMPTOM MIGHT APPEAR.
Symptom: Vertical line Block

Cause: Countermeasure:
  1. Open or contact failure of Data flexible Cable àClean, Reconnect or exchange connector.
  2. Failure in Data IC à Exchange PDP
  3. Failure in Data Relay Board à Exchange the Data Relay Board.
  4. Failure in multiple Data IC à Exchange PDP.
Symptom: Horizontal lines
Cause: Countermeasure:
  1. Failure in Scan IC on Scan Relay Board - Exchange Scan Relay Board.Open or contact failure of Scan Flexible Cable (CN01-CN04) at output side of Scan Relay Board (U,D). à Clean, Reconnect or exchange connector.
  2. Contact failure of connector between Scan Board and Scan Relay Board. à Clean, Reconnect or exchange connector.
  3. Short between terminals of Scan IC due to screw dust à Clean around the terminals.
Symptom: No Picture (Priming flash).
Cause: Countermeasure:
1F302 open. à Exchange High Voltage Board.
  • If the connector CN7709 disconnected from Data Relay Board (RU ) is short-circuited between Pin 1 (or 2) and GND (Pin 3 or 4) à Data IC is broken à Exchange PDP.
  • If the connector CN7709 disconnected from Data Relay Board (RU) is short-circuited between Pin 5 (or 6) and GND (Pin 3 or 4) à Data Relay Board (LU) or (RU) is failed ]
  •  If the connector CN7608 disconnected from Data Relay Board (LU) is short-circuited between Pin 1 and GND (Pin 2 or 6) à Data Relay Board (LU) is failed à Exchange Data Relay Board (LU).
  • If the connector CN7708 disconnected from Data Relay Board (RU) is short-circuited between Pin 1 and GND (Pin 2 or 6) à Data Relay Board (RU) is failed à Exchange Data Relay Board (RU).
  • If the connector CN7909 disconnected from Data Relay Board (RD) is short-circuited between Pin 1 (or 2) and GND (Pin 3 or 4) à Data IC is broken à Exchange PDP.
  • If the connector CN7909 disconnected from Data Relay Board (RD) is short-circuited between Pin 5 (or 6) and GND (Pin 3 or 4) à Data Relay Board (LD) or (RD) is failed]
  • If the connector CN7808 disconnected from Data Relay Board (LD) is short-circuited between Pin 8 and GND (Pin 3 or 7) à Data Relay Board (LD) is failed à Exchange Data Relay Board (LD).
  • If the connector CN7908 disconnected from Data Relay Board (RD) is short-circuited between Pin 8 and GND (Pin 3 or 7) à Data Relay Board (RD) is failed à Exchange Data Relay Board (RD).
Symptom: No Picture. (Priming doesn’t flash if W-X terminals are short-circuited.)
Cause/Countermeasure:  No Diode characteristic à Exchange High Voltage Board.
Symptom: Abnormalities in a picture.
ONE OR MORE VERTICAL BANDS, MULTIPLE VERTICAL BANDS
OUT OF SYNCHRONIZATION OR DUPLICATION
RECTANGULAR COLOR SHEAR, COLOR DISCREPANCY, SHEAR IN DISPLAY
TRANSPARENT VERTICAL BAND
MOSAIC
A NUMBER OF LATERAL LINES, REGULAR NOISE
Cause: Countermeasure :
  • Contact failure of connector adjacent to Digital Board or short circuit due to conductive obstacle. à Clean or Reconnect.
  • Failure in circuit on Digital Board.  à  Failure in Digital Board.

PIONEER PDP-42A3HD - PDP-4214HD - FAULTS & SYMPTOMS 



         

POWER OFF
Symptom: No Picture (Priming doesn't flash)  >  Power off.

Cause | Countermeasure:
  • F301 open à Exchange High Voltage Board.
  • FU801 open à Exchange Digital Board.
Cause | Countermeasure :

  • If short-circuited, disconnect connector between High Voltage Board and Scan Relay Board and,
  • Short between NEGA-POSI on High Voltage Board  à Exchange High Voltage Board.
  • Short between NEGA-POSI on Scan Relay Board (U) à Exchange Scan Relay Board (U).
  • Short between NEGA-POSI on Scan Relay Board (D) à Exchange Scan Relay Board (D).
  • Symptom: No Picture à Power off (Priming flash).
  • Cause | Countermeasure: R91 open à  Exchange High Voltage Board.
Symptom: Failure in Writing  à Power off.
DARK AND ROUGH PICTURE
MANY LIGHT SPOTS ON DARK PORTION
WHITE PATTERN EVEN IN NO SIGNAL -- POWER OFF
Cause | Countermeasure: 
  • R43,R61 open à Exchange High Voltage Board.