Monday, 1 April 2019

DAYTEK LC2018NT SERVICE MODE - DIGITAL FLAT DISPLAY - POWER SUPPLY SCHEMATIC

SERVICE MODE - DAYTEK LC2018NT Digital Flat Display - POWER SUPPLY SCHEMATIC

DAYTEK Digital Flat Display LC1508NT - LC1521NT - LC2018NT _ Service Mode_Power Supply Schematic_Universal Remote Control Set-up Codes
SERVICE MODE [Factory Mode]
Enter factory mode adjustment using the remote control.
* Press Menu button once first
* Then press PRE.CH (or named RECALL) button five times, and you can see manufacture menu on the LCD panel.
* Press the Channel[ +/-] button to selection the sub menu of factory menu( including F, E, UOCⅢ, RGBTemp, Temp and press the Volume + to enter the sub menu and setting the value.
* Press the MUTE button again and again or turn off the TV, it can exit the factory menu.
UNIVERSAL REMOTE CONTROL SET-UP CODES TO CHECK WITH DAYTEK TVs:  0194 0655 0658 0720
POWER SUPPLY SCHEMATIC {Click on the schematic to Zoom In}