Sony 3D DLP projector – Sony VPL-HW30ES - HW30AES – How to replace the projector lamp – How to remove and clean the airlifter - How to rest the lamp hour
Sony VPL-HW30ES
- HW30AES
How
to replace the Lamp
1.
Turn off the projector and unplug the AC power cord.
2. When setting the projector on a flat surface such as a desk etc., put a cloth to prevent the surface from being scratched. Reverse the projector as illustrated, then place it on the cloth.
2. When setting the projector on a flat surface such as a desk etc., put a cloth to prevent the surface from being scratched. Reverse the projector as illustrated, then place it on the cloth.
3.
Loosen the screw on the lamp cover with a Philips screwdriver, and then
open the lamp cover.
4.
Loosen the 3 screws on the lamp with the Phillips screwdriver. Hold up the
handle, then pull the lamp straight out.
5.
Hold the handle of the new lamp and push it in securely until it reaches
the end, and then tighten the 3 screws.
6.
Close the lamp cover, and then tighten the screws.
Air
Filter Cleaning
1.
Remove the filter holder.
2.
Remove the air filter.
3.
Attach the new air filter so that it fits into the each claws (10
positions) on the filter holder.
Attach
the air filter aligning it with the shape of the filter holder. Also, do not
touch the fan after removing the air filter that is set deep inside the
projector.
4. Attach the filter holder.
The projector will not turn on unless the filter holder is securely closed.
5. Wipe dust off the ventilation holes (intake) with a soft cloth.
4. Attach the filter holder.
The projector will not turn on unless the filter holder is securely closed.
5. Wipe dust off the ventilation holes (intake) with a soft cloth.
6.
Place the project back on its original position.
7.
Turn on the projector, then select the desired setting item on the Setup menu.
The menu screen will appeared.
8.
Select “Yes”.
Do
not put your hands into the lamp replacement slot, and do not allow any liquid
or other objects into the slot to avoid electrical shock or fire.