Wednesday, 29 January 2020

REPAIR / SERVICING TV PHILIPS 40PFL3107H

Technical description and composition of the PHILIPS 40PFL3107H TV, type of panel and applicable modules. The composition of the modules.
PHILIPS LED
Model: 40PFL3107H / 60
Chassis / Version: TPM9.2E LA
Panel: LTA400HM23 001 code 182
LED backlight: SSL400_WP01
T-CON: 7512N 1245, i7939A H2497FG (12x4), LQF6041T0B-Q1, 24C64WP (8), SM4152 DA1242 SMC0042
LED driver (backlight): DLED400S4LV0.1 SSL400_005A Rev1.0
PWM LED driver: TR10E1
MOSFET LED driver: SF10A400HD
Power Supply (PSU): 715G5246-P03-000-002H // 715G5246-P01-000-002S
PWM Power: SSC9512S, LD7523GS, A6069H (Standby), R2A20113 (PFC)
MainBoard: 715G5155-M02-002-005K VerA
IC MainBoard: MT5366ZVGG, H5TQ1G63DFR-H9C, TMDS361BPAGR
Tuner: ENV57U09D5F
Control: Remote: 9965 900 00449, IR: 715G5230-R02-000-004s
Specifications 40PFL3107H
PHILIPS 40PFL3107H
General repair guidelines for TV LCD LED
PHILIPS 40PFL3107H / 60, like other televisions, it is advisable to start repairing with a careful examination of the external and internal elements and modules. Using visible changes in the state of components, it is usually possible to determine the further direction of troubleshooting and localization of the defect before the necessary measurements are taken. Carbonized paint on the upper layer of resistors, electrolytic capacitors of rectifier filters swollen after boiling, cracked soldering at the terminals of heating elements or transformers can often suggest the cause of the defect and possible consequences.
If the power supply module 715G5246-P03-000-002H malfunctions, the external manifestations may be different, for example, PHILIPS 40PFL3107H does not turn on at all and there is no indication of the indicator lights on the front panel. With the same symptoms, the stabilizer (converter) of the power supply to the control processor may be faulty. When diagnosing and repairing the power supply, after replacing the swollen capacitors of the secondary rectifier filters (if any), you must first check the mains fuse. When it is broken, the power elements of transistors and rectifier bridge diodes should be checked for avalanche (thermal) breakdown.
It should be remembered that in the practice of repair, usually the power switches in switching power supplies (SMPS) do not fail due to their poor quality and, in such cases, it is necessary to look for the cause that led to a malfunction and provoked a breakdown of the key. Most often, the culprits of the accident are dried electrolytic capacitors or dangling resistors in the primary circuit, or the A6069H PWM controller chip itself may be faulty. It is also necessary to check all the semiconductor elements of the stabilization circuit in the primary and secondary circuits.
In cases where the PHILIPS 40PFL3107H TV has lost an image, and the sound is there and all the other functions are functional, there is a possibility of a malfunction of the LED driver (converter for powering the backlight LEDs of the LTA400HM23 panel). When you turn on the TV, the image may appear briefly and disappear immediately. It must be borne in mind that with such manifestations the LEDs themselves also fail.
A malfunction in the backlight circuits often occurs due to an open in the power circuit of the LED lines. It is necessary to disassemble the panel and check the LEDs themselves, the soldering of their conclusions, as well as the reliability of the connections in the connectors and the soldering of the conclusions of the connectors.
It is impossible to detect a break in the LED line without disassembling the panel with a simple multimeter. The LEDs are connected in series and to open their transitions, a voltage of several tens of volts is required. Ideally, a current source is suitable for such purposes.
Repair of the 715G5155-M02-002-005K VerA motherboard should begin with the diagnosis and verification of all linear stabilizers or power converters of its microcircuits. Sometimes it may be necessary to update the software (software) - flashing FLASH or EEPROM.
If the TV works normally from external devices, but does not tune into television channels, the tuner ENV57U09D5F may be malfunctioning. In such cases, first of all, you should make sure that there are supply voltages at its corresponding terminals, as well as the power supply of varicaps (30-33V).
We recommend the owners of the 40PFL3107H TV for repair only to qualified specialists with experience! Self-repair attempts without the appropriate knowledge and skills can lead to serious negative consequences!
Typical problems associated with the lack of a PHILIPS 40PFL3107H / 60 image occur due to Samsung's problematic LTA400HM23 LED panel.
External manifestations: no image, sometimes appears, but disappears again.
In most of these cases, panel repair is possible and widely practiced by repairmen. Faulty LEDs must be replaced and duplicated contacts duplicated by conductors. For prevention purposes, it is advisable to duplicate all contact connections between the LED strips.

Service manual and schematic diagram 40PFL3107H/60 Chassis TPM9.2E LA


32PFL3517H/12, 32PFL3507K/02, 32PFL3517K/02, 37PFL3507H/12, 37PFL3507K/02, 42PFL3507H/12, 42PFL3507K/02



 Appearance of MainBoard 715G5155-M02-002-005K is shown in the figure below:
715G5155-M02-002-005K
715G5155-M02-002-005K_PCB
715G5155-M02-002-005K can be used in TVs:
PHILIPS 40PFL3107H/60 (Panel LTA400HM23 001 code 182), PHILIPS 40PFL3108T/60 (Panel LTA400HM23 001 SAMSUNG code 182 p/n: 996590004008), PHILIPS 40PFL4308T/60 (Panel LTA400HM23), PHILIPS 26PFL3207H/12 (Panel TPT260B2-L03 Rev. C1C).
PSU Advanced
According to the conditions of compliance with modern world standards for household switching power supplies, the 715G5246-P03-000-002H module provides for the use of the Power Factor Correction unit. The PFC circuit is a flyback converter based on the R2A20113 PWM controller. The reactance of an electrolytic capacitor of a line filter at a frequency of 50-60 Hz is usually not more than 20-30 ohms and its charge directly from the network through open diodes could reach tens of amperes per pulse if no filtering was applied.
As a result of the PFC conversion, an increased voltage on the capacitor (about 380V) cannot directly open the rectifier diodes, on the anode of which the voltage will always be slightly less (about 300V) and then its charging current will always be limited by the elements of the PWM controller. As a result, the envelope of the high-frequency pulses of the consumed current will repeat the shape and phase of the input sinusoidal voltage. The presence of an increased voltage (+ 380V) on the network capacitor indicates the serviceability of the PFC node.
The appearance of the power supply
Main features of the PHILIPS 40PFL3107H device:
Installed matrix (LED-panel) LTA400HM23 001 code 182.
The matrix control uses the Timing Controller (T-CON) 7512N.
The LED driver DLED400S4LV0.1 is used to power the backlight LEDs, it is controlled by the TR10E1 PWM controller. As the power elements of the LED driver, keys of the type SF10A400HD are used.
The necessary supply voltages for all nodes of the PHILIPS 40PFL3107H TV are generated by the 715G5246-P03-000-002H power module, or its analogs using SSC9512S, LD7523GS, A6069H (Standby), R2A20113 (PFC) microcircuits.
MainBoard - the main board (motherboard) is a module 715G5155-M02-002-005K, using chips MT5366ZVGG, H5TQ1G63DFR-H9C, TMDS361BPAGR and others.
The ENV57U09D5F tuner provides TV reception and channel tuning.
Additional technical information about the panel:
Brand: SAMSUNG
Model: LTA400HM23
Type: a-Si TFT-LCD, Panel
Diagonal size: 40 inch
Resolution: 1920x1080, FHD
Display Mode: S-PVA, Normally Black, Transmissive
Active Area: 885.6x498.15 mm
Surface: Antiglare (Haze 5.5%), Hard coating (2H)
Brightness: 300 cd / m²
Contrast Ratio: 5000: 1
Display Colors: 16.7M (6-bit + Hi-FRC), CIE1931 70%
Response Time: 8 (G to G)
Frequency: 60Hz
Lamp Type: WLED Embedded (LED Driver)
Signal Interface: LVDS (2 ch, 8-bit), 51 pins
Voltage: 12.0V