This simple Touch Switch Circuit by using a 555 timer IC operated as a MONOSTABLE vibrator. Here the IC is configured as an monostable multivibrator, in this mode the IC activates its output momentarily by producing a logic high in response to a trigger at its input pin#2.
The momentary activation time period of the output depends on the value of C1 and the setting of VR1.
When the touch switch is touched pin#2 is pulled to a lower logic potential which may be less than 1/3 of Vcc. This instantly reverts the output situation from low to high activating the connected relay driver stage.
This in turn switches ON the load attached with the relay contacts but only for the time until C1 gets fully discharged.
Welcome to Master Electronics Repair! website.Here you will find:Service Modes, Circuit Diagrams,Service manuals, Firmware Update procedure, Disassemble procedure, Universal remote control setup codes, Troubleshooting, Diagnosing, Measuring, and more.... of many of LCD/LED TV/Displays,others various electronic apparates,trough many technical notes and tips/tricks to help repairing/fixing Troubles/ faults,for electrical technicians.This site helps you to save the Earth from electronic waste!