The following explanations are only for T370HW02-V.4 coded panel and T370HW02 T-con Board. Absolutely useless on different panels and T-cons.
PROBLEM: The image turns white 5-10 minutes after the first run:
SOLUTION: Replace AS15 IC (Gamma Process-IC )Channel Voltage Buffers for TFT LCD.
T-con voltages:
T-con voltages:
VGMA22 : : 0V36
VGMA21 : : 0V4
VGMA20 : 0V54
VGMA19 : 2V90
VGMA18 : 3V57
VGMA17 : 4V37
VGMA16 : 4V84
VGMA15 : 5V07
VGMA14 : 6V31
VGMA13 : 6V6
VGMA12 : 6V64
VGMA11 : 7V9
VGMA10 : 7V96
VGMA9 : 8V3
VGMA8 : 9V83
VGMA7 : 10V1
VGMA6 : 10V66
VGMA5 : 11V62
VGMA4 : 12V43
VGMA3 : 15V28
VGMA2 : 15V43
VGMA1 : 5V5