REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Tuesday 5 February 2019

THOMSON LCD12B2 – HOW TO ENTER SERVICE MODE – ADJUSTMENTS – SMPS CIRCUIT DIAGRAM – LCD TV MT62B CHASSIS

Thomson LCD12B2 – How to enter service mode – adjustments – SMPS circuit diagram – LCD TV MT62B Chassis

Service mode alignments - SMPS [Power Supply Regulator board] schematic - Thomson LCD12B2 
Factory Alignment
The MT62 chassis is designed for European LCD TV. The main chip is from Mediatec (MTK5362 series) and supports below inputs:
* one analog and digital mixed RF (PAL B/G D/K I, SECAM B/G D/K L/L’,DVB-T)
* one Side AV(CVBS )
* one SCART (CVBS & RGB)
* one SCART (CVBS & YC)
* one CMP (YPrPb can support from 480i up to 1080p)
* one VGA
* three HDMI (can support 480i/p, 576i/p, 720p up to 1080i/p) compliant v1.2. With HDCP, audio included as EIA-861B standard
* one Headphone output
* one SPDIF output
Preconditions – DC/DC Check
Before Power On the chassis, please check and make sure that U811,U9,U31, U7, U6, U11, U5,U4,U34,C74(positive) , C62(positive) , C76(positive) , C152(positive) , C89(positive) , C82(positive) outputs are not shorted to ground.
Supply voltage to P19 and test the relative voltage.
Supply P19 : Pin5,6,8=12v (24v work with IPB PSU);Pin11,12=5v;Pin1,2=Voltage for sound Amplifier IC (18V for 46/52 inch;12V for other inch )
Panel ID check and modify
There is different ID stored in the NVM depended on different Panels. The correct number should be checked in factory menu and if not correct according to the panel list , should be correct manually. The simple way is that select the correct Id in factory menu and restart the set. If the wrong ID make the set display nothing, it must be correct with Hyper terminal.
Once the boards (chassis, KB, IR, PSU…) and the panel are well interconnected, connect all external generator devices to relevant inputs/outputs below according to their respective test patterns format and check picture content and sound quality accordingly.
Audio tones can be defined by the factory (ie: 1KHz & 3KHz, sweep, …).
Picture video formats can be changed by the factory according to their own standard.
ADC Calibration
To ensure the ADC performance, the error of “generator+cable” must be less than 2%. Three inputs require an ADC calibration for the time being, They are:
ƒ VGA
Provide a test signal 1024×768@60Hz with White-black squares.
Select the corresponding “Auto Color” in “ADC Calibration” sub-menu of “Factory Menu”, then press ”OK” to start. Value of status will change to “ALL” if succeed.
CMP:
TestAlignmentSpecification for TCL-MT5362-V0.50.doc
Provide a test signal 576i@50Hz with 100% 8 steps ColorBar.
Select the corresponding “Auto Color” in “ADC Calibration” sub-menu of “FactoryMenu”, then press ”OK” to start. Value of status wil change to “ALL” if succeed. Scart RGB
Provide a test signal 100% 8 steps ColorBar.
Select the corresponding “Auto Color” in “ADC Calibration” sub-menu of “FactoryMenu”, then press ”OK” to start. Value of status will change to “ALL” if succeed.
DDC & EDID Test
The E-EDID data structure are according to VESA Enhanced EDID 1.3 (and EIA/CEA-861B for HDMI).
Both VGA and HDMI have their own separate bin files:
For EDID check, it’s needed to check whether the correct EDID is downloaded by checking corresponding EDID NVM Checksum or read them out to check bit by bit if it is in line with the released EDID bin file.
HDCP Test
For HDCP compliancy, it’s needed to check whether the HDCP key has been well set.
Entering to “Factory Menu” [Service Mode]
To enter into Factory Menu in case of “FactoryKey” is disabled, please to follow below steps:
- press Remote Control key “MENU” to display main menu
- press the subsequent Remote Control keys “7”, “9”, “1” and “5
The main menu will display”FACTORY” at the last item.
To pop-up Factory Menu in case of “Factory Key” is enabled, please to follow below step:
- press Remote Control key “Blue”
To enable/disable “Factory Key”, follow below steps:
- press Remote Control “OK”key to enter into “System” sub-menu
- press Remote Control “RIGHT”or “LEFT” key till “Factory Key” item
- press Remote Control “Menu”key to toggle mode
To exit “Factory Menu”, press “Exit” key from Remote Control.
To comeback to “Factory Menu” root when you are into a sub-menu:
- press Remote Control “Menu” key.
Entering to “P” Mode
Turned on the factory key to enter into “P” mode.The TV will display “P” in bottom left corner in “P” mode.
Serial Command Protocol for MTKxx”
A serial protocol for driving MTK µchip through external +3.3VDC serial device (USB or COMx) is available. It may facilitate manufacturing process.
1. Both P201 connector from chassis board or either VGA input can also be used using pin12 (RXD) & pin15 (TXD) just taking care that “Factory Key” from Factory Menu is enabled.
2. The required serial port settings are as below
* 115200 bps
* 8 data bit
* 1 bit stop
* none parity
3. The command format is like hereafter described into BNS representation:
* 0xBB + Command + Data[[..] + ..] + 0xEE
Both 0xBB and 0xEE bytes are mandatory and used as header and footer of the transmitted frame. Apart from INIT frame that is described further, all sent bytes need to be triggered before by an additional one as 0x50. So a complete frame might match following one:
* 0x50+0xBB+0x50+Command+0x50+Data[[..]+0x50+..]+0x50+0xEE
4. At first time, it might be required to initialize MTK µchip by using once below INIT command (without any triggering byte):
* 0x02 + 0x00 + 0x00 + 0x13 + 0x01 + 0x00
5. A none exhaustive list of commands is already available.
Error link!  In invalid.
Modify panel ID with Hyper terminal
1. Connect the PC to the mainboard using an external +3.3VDC serial device (USB or COMx) on P9 or P18 connector from chassis board.
2. Provide the voltage on P19 connector (Pin5,6,8=12v;Pin11,12=5v) from chassis board
3.Save the password file “password for hyperTerminal.txt” to your computer.
4. Start HyperTerminal “HyperTrm.exe” in your computer.
5. Fill the name.
6. Select the Com Port you are using.
7. Set the items as below picture.
Select “File >Save >” to Save the setting. Then start HyperTerminal “atsc.ht” in your computer instead of step 3 to 7 later.
8. Send the password.
9. Select the password file saved in your computer.
10. Under the folder “DTV>” enter “pmx.s.p +ID”,e.g.: pmx.s.p 102
See the panel ID in another document <Panel list for MT62>.
Press “Enter”, the panel signal will be printed in the window.
SMPS circuit diagram [Schematic] [Click on the pictures to zoom in]