REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Saturday 9 March 2019

HITACHI 32PD5000/5100/5200/5300 - 42PD5000/5100/5200/5300 - 37PD5200/42PMA500E - 55PMA550E/55PD5200 SERVICE MODE AND POWER SUPPLY CIRCUIT

HITACHI 32PD5000/5100/5200/5300 - 42PD5000/5100/5200/5300 - 37PD5200/42PMA500E - 55PMA550E/55PD5200 SERVICE MODE AND POWER SUPPLY CIRCUIT

HITACHI 32PD5000/5100/5200/5300 - 42PD5000/5100/5200/5300 - 37PD5200/42PMA500E - 55PMA550E/55PD5200 

SERVICE MODE AND POWER SUPPLY CIRCUIT 

REMOTE CONTROL PART NUMBERS
37PD5000TE CLE-958
37PD5000VE  CLE-952A
Adjustment
SERVICE MODE 
Using the front control buttons with the set turned off (standby) can activate it.
Press the SUB-POWER button, INPUT SELECT button and button at the same time, and hold for more than 5 seconds.
The set turns on in adjustment mode with OSD.
Changing data and Selecting Adjustment code
When the set is in adjustment mode, the cursor UP,DOWN,LEFT,RIGHT and OK buttons of the remote control or front panel may be used as the adjustment keys.
UP, DOWN buttons are used for selecting adjustment code.
LEFT,RIGHT buttons are used for changing data values.
OK button is used for confirming the data.
After finishing the necessary adjustment press MENU button. Adjustment mode is released and the set returns to normal condition.
Memory Initialize operation
NOTE: The execution of this function returns the adjustment codes to the preset values, therefore, adjustment data will be lost.
Procedure
(1) Enter Adjustment Mode.
(2) Select MEMORY INIT adjustment code (No.704) and change the data value from 0 to 1.
(3) Activate MEMORY INIT by pressing OK button for more than 3 seconds.
(4) Select No.374 and change data value from 1 to 0.
(5) Check that the receiving channel goes to AV1. Unit is set to preset values.
Factory Reset
After all of the adjustments of main chassis are finished, perform FACTORY RESET.
Press the SUB-POWER button, INPUT SELECT button and UP button at the same time, and hold for more than 5 seconds. The unit is set to factory settings.
VOLTAGE ADJUSTMENT
32PD5000, 37PD5000, 37PD5000
Preparation
(1) Keep heat-run for 1 minutes or more.
(2) Connect the DC Voltmeter to the Vs test point and the GND point (or the Va test point and the GND point) on the Power Supply Unit.
(3) Receive the all black signal with no setup.
(4) Check the indication of Vs and Va voltages printed on the label located upper right side on the Panel Module.
Procedure
(1) If the difference between the printed voltage of Vs and the indicated value of Vs Voltmeter is over 0.1V, adjust the Vs ADJ VR located upward on the Power Supply Unit to make it within 0.1V.
(2) If the difference between the printed voltage of Va and the indicated value of Va Voltmeter is over 0.2V, adjust the Va ADJ VR located upward on the Power Supply Unit to make it within 0.2V.
(3) Check and do the procedure (1) again.
<Example of the Voltage Label>
Vs= 80.0V, Va=60.0V
Vw=140.0V ,Vx=60.0V
VOLTAGE ADJUSTMENT
55PMA550E
Preparation
(1) Keep heat-run for 1 minutes or more.
(2) Connect the DC Voltmeter to the Vs test point and the GND point (or the Va test point and the GND point) on the Power Supply Unit.
(3) Receive the all black signal with no setup.
(4) Check the indication of Vs and Va voltages printed on the label located upper right side on the Panel Module.
Procedure
(1) If the difference between the printed voltage of Vs and the indicated value of Vs Voltmeter is over 0.1V, adjust the Vs ADJ VR located upward on the Power Supply Unit to make it within 0.1V.
(2) If the difference between the printed voltage of Va and the indicated value of Va Voltmeter is over 0.2V, adjust the Va ADJ VR located upward on the Power Supply Unit to make it within 0.2V.
(3) Check and do the procedure (1) again.
<Example of the Voltage Label>
Vs= 82.0V, Va=63.0V
Vw=180.0V ,Vx=40.0V
Troubleshooting
How to get to Burn-in mode
This mode displays the test patterns of some single color raster in turn. These signals are from built-in generator of PDP panel. So it can be presumed that maybe the panel has some trouble when the screen of Burn-in mode is abnormal.
Using the front control buttons with the set turned off (standby) can activate this mode.
Press the SUB-POWER button, INPUT SELECT button and VOLUME DOWN button at the same time, and hold for more than 5 seconds.
The set turns on with single color raster and the OSD of [BURN IN: ON].
 To escape from this mode, press the SUB-POWER  button, INPUT SELECT  button and UP button at the same time, and hold for more than 5 seconds. Burn-in mode will be released.
How to recover the remote and front key function
If remote and front key cannot operate after miss set special function by front keys, these functions can recover by below method.
Press the SUB-POWER button, INPUT SELECT  button and DOWN button at the same time, and hold for more than 5 seconds. The set turns on the service menu mode.
Select No.175 and data set from [0] to [1].
Or
Press the SUB-POWER  button and DOWN button at the same time, and hold for more than 5 seconds.
Forced AVC mode (only for 37PD5200)
This model is set to "Forced AVC" mode. It makes the set cannot be turned on without connecting AVC.
Following procedures should be referred when servicing 42/32PD5200 without AVC box.
Procedure of escaping from this mode (before servicing)
Using the front control buttons with the set turned off (standby) can activate it.
Press the SUB-POWER button and VOLUME UP button at the same time, and hold for more than 5 seconds.
The set will be changed that the power of the monitor can be turned on without AVC.
Procedure of getting into this mode again (after servicing)
(1) Enter Adjustment Mode.
(2) Select adjustment code (No.323) and change the data value from 0 to 1.
The set will be changed again that the power of the monitor cannot be turned on without AVC
POWER SUPPLY CIRCUIT 
FOR REFERENCE PURPOSE ONLY  