REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Wednesday 6 March 2019

LG CASSETTE AIR CONDITIONER LCN240CP - LCN380CP ERROR ODE AND TROUBLESHOOTING - AIR CONDITIONER SERVICE AND REPAIR

LG CASSETTE AIR CONDITIONER LCN240CP - LCN380CP Error ode and troubleshooting - Air conditioner service and repair.

LG  

INDOOR UNIT LCN240CP - LCN380CP

OUTDOOR UNITLCU240CP - LCU380CP


Self-diagnosis Function
Error Indicator
# The function is to self-diagnoisis airconditioner and express the troubles identifically if there is any trouble.
# Error mark is ON/OFF for the operation LED of evaporator body in the same manner as the following table.
# If more than two troubles occur simultaneously, primarily the highest trouble fo error code is expressed.
# After error occurrence, if error is released, error LED is also released simultaneously.
# To operate again on the occurrence of error code, be sure to turn off the power and then turn on.
# Having or not of error code is different from Model.
Troubleshooting CH01, CH02, CH06
Display code
Title
Cause of error
Check point & Normal condition
01


Indoor air sensor


Open / Short
Soldered poorly
Internal circuit error
Normal resistor : 10KΩ/ at 25°C (Unplugged)
Normal voltage : 2.5Vdc / at 25°C (plugged)



02




Indoor inlet pipe sensor



Open / Short
Soldered poorly
Internal circuit error


Normal resistor : 5KΩ/ at 25°C (Unplugged)
Normal voltage : 2.5Vdc / at 25°C (plugged)



06


Indoor outlet pipe sensor

Open / Short
Soldered poorly
Internal circuit error


Normal resistor : 5KΩ/ at 25°C (Unplugged)
Normal voltage : 2.5Vdc / at 25°C (plugged)

 Check Point
1. Unplug the sensor on Indoor unit PCB.
2. Estimate the resistance of each sensor.
3. If the resistance of the sensor is 10KΩ/ 5KΩ at 25°C, then sensor is normal.
4. If the resistance of the sensor is 0 KΩ or infinite, then sensor is abnormal. > Change the sensor.
5. Plug the sensor on Indoor unit PCB and Power ON.
6. Estimate the voltage of each sensor.
7. If the voltage of the sensor is 2.5Vdc at 25°C, then sensor is normal.
8. If the resistance of the sensor is 0 or 5Vdc, then sensor is abnormal.  >Repair or Change the PCB.
Troubleshooting CH03
Display code : 03
Title: Communication Wired R/C
Cause of error
# Open / Short
# Wrong connection
Check point & Normal condition
Connection of wire
Main PCB Volt. DC12V
Noise interference
Check Point
1. Check the wire connection. (Open / Short) >  Repair the connection
2. Check the soldering state of connector. (Soldered poorly) > Repair or Change the PCB.
3. Check the volt. Of main PCB power source. (DC 12V, DC 5V)> Repair or Change the main PCB.
4. Check the installation of wired remote controller. (Noise interference) > Adjust the state of installation
Troubleshooting CH04
Display code : 04
Cause of error
Drain pump / Float switch
Cause of error
# Float switch Open (Normal : short)
Check point & Normal condition
The connection of wire(Drain pump/ Float switch)
Drain pump power input. (220V)
Drain tube installation.
Indoor unit installation. (Inclination)
Check Point
1. Check the wire connection. (Open, Soldered poorly)  > Repair the connection or change the PCB.
2. Check the resistance of float switch (Abnormal : Open, Normal : short) > Check the float switch.
3. Check the level of water
4. Check the volt. Of Drain pump power supply. (AC 230V) >  Repair or Change the main PCB.
Troubleshooting CH05, CH53
Display code : 05/53
Cause of error
Communication
(Indoor > Outdoor)
Check point & Normal condition
Power input AC 220V. (Outdoor, Indoor)
The connector for transmission is disconnected.
The connecting wires are misconnected.
The GND1,2 is not connected at main GND.
The communication line is shorted at GND.
Transmission circuit of outdoor PCB is abnormal.
Transmission circuit of indoor PCB is abnormal.
Check Point
1. Check the input power AC230V. (Outdoor, Indoor unit)
2. Check the communication wires are correctly connected.
# Adjust the connection of wire
# Confirm the wire of “Live”, “Neutral”
3. Check the resistance between communication line and GND. (Normal : Over 2MΩ)
4. Check the connector for communication is correctly connected.
5. Check the connection of GND1, GND2, and main GND.
6. If one indoor unit is operated normally, outdoor PCB is no problem.
# Check the another indoor unit.
 CH05 is displayed at indoor unit, CH53 is displayed at outdoor unit.
Troubleshooting CH24, CH25
Display code
Title
Check point & Normal condition
24

Press S/W Open

Check the connection of “CN_Press”.
Check the components.

25

Input voltage
Check the power source.
Check the components.
Check Point
# CH 24
1. Check the connection of “CN_PRESS”
2. Check the install condition for over load.
3. Check the SVC V/V open.
4. Check the leakage of refrigerant.
# CH 25
1. Check the power source.
2. Check the components
(Trans1, B/Diode, Diode, Resistance)