REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Wednesday 6 March 2019

SHARP HT-SB250 HOME THEATRE SOUND BAR SYSTEM FACTORY RESET – TEST MODE – E1- E2- E3 ERROR CODES – DISASSEMBLING PROCEDURE

SHARP HT-SB250 HOME THEATRE SOUND BAR SYSTEM Factory reset – Test mode – E1- E2- E3 Error codes – Disassembling procedure


                                        Category: Home theatre Audio system repair and service  

Contents of this article 
  • Factory Reset Of the system
  • Test mode 
  • Disassembling 

SHARP HT-SB250

Factory reset
Make sure to disconnect all audio input cables attached to the unit before performing the factory reset.
1. Press the ON/STAND-BY button to enter the power stand-by mode.
2. While pressing the SURROUND button, press and hold the ON/ STAND-BY button until “CL” appears.
If problem occurs during operation
When this product is subject to strong external interference (mechanical shock, excessive static electricity, abnormal supply voltage due to lightning, etc.) or if it is operated incorrectly, it may malfunction.
If such a problem occurs, do the following
1. Set the unit to the stand-by mode and turn the power on again.
2. If the unit is not restored in the previous operation, unplug and plug in the unit, and then turn the power on.
Test Mode
Enter the Test Mode version display
While pressing down ON/STANDBY and VOL UP button, ON AC supply.
Version will be display on 7 segment as below:-
S2 --> XX --> D
S2 = Model name, SB250
XX= version no.
D = Destination
Enter Key and Display Test Mode
After enter Test Mode version display, Press VOL UP button.
1. All SOUND MODE LED will light ON
2. 7 segment display will light on if press button as below
Key
7 segment
VOL DOWN
01
VOL UP
02
SURROUND
03
FUNCTION
04
Exit the Test Mode
While in Test Mode function, Press ON/STANDBY button to exit.
Error Code Description
Display
Explanation
Solution
E1
Communication error between Micom and WM8775
> Unplug AC cord and turn power ON again
> Check line connected between Micom and corresponding IC
E2
Communication error between Micom and NJU26040
E3
Communication error between Micom and STA333
Error indicators and warnings
Power indicator (blinks red)
When the protection circuit is activated.
System Protection indicator
In case abnormal power detection has occurred, the unit will automatically enter to stand-by mode ON/Standby LED willl be flashing as below:-
                                                Example for No. 2 AVCK Protect
Unit enter Protect mode when irregular process occur on power supply line.
1. System Protect
2. AVCK Protect
Disassembly
Follow the below-mentioned notes when disassembling the unit and reassembling it, to keep it safe and ensure excellent performance:
1. Be sure to remove the power supply plug from the wall outlet before starting to disassemble the unit.
2. Take off nylon bands or wire holders where they need to be removed when disassembling the unit. After servicing
the unit, be sure to rearrange the leads where they were before disassembling.
3. Check that all speaker cushions  are properly sealed otherwise vibration noise will be very distinct at low frequency sound.
Replace the cushions if they are found damaged during servicing.

Output power of the amplifiers 
Front speaker:
RMS: 12 W (6 W + 6 W) (10% T.H.D.)
RMS: 9.6 W (4.8 W + 4.8 W) (0.9% T.H.D.)
Subwoofer:
RMS: 20 W (10% T.H.D.)
RMS: 13 W (0.9% T.H.D.)