REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Monday 8 April 2019

SONY DIGITAL MOTION PICTURE CAMERA - SONY F65 – ERROR INDICATION AND FAULT – HOW TO MOUNT SR-R4 – HOW TO ATTACH FILTER

Sony Digital Motion Picture Camera - Sony F65 – Error indication and fault – How to mount SR-R4 – How to attach filter


Sony F65:  Error Messages and causes 
If the battery voltage drops or an error is detected when power is applied or during operation, the corresponding indicator lights up/flashes and a message appears on the subdisplay. The error details are displayed in the selfdiagnostics on settings page 3 on the subdisplay and in the viewfinder.
Warnings and error messages occurring on the SR-R4 are also displayed in the self-diagnostics field.
A message prompt is also displayed in the viewfinder/ monitor to execute the APR function if a defect is detected in the image sensor when the camera powers on or if the APR function is not executed regularly. If prompted, execute Automatic Pixel Noise Reduction
Indicator
Subdisplay
Self diagnostics field indication
Meaning

REC: Flashing red



12 V power supply voltage indicator flashing



12V Battery (Near End)


The voltage of the 12 V power supply has fallen to the
Near End value setting.



REC: Flashing red rapidly



12 V power supply voltage indicator flashing   rapidly



12V Battery (End)


The voltage of the 12 V power supply has fallen to the
End value setting.



REC: Flashing red



24 V power supply voltage indicator flashing



24V Battery (Near End)


The voltage of the 24 V power supply has fallen to the
Near End value setting.


REC: Flashing red rapidly


24 V power supply voltage indicator flashing   rapidly


24V Battery (End)
The voltage of the 24 V power supply has fallen to the
End value setting.

REC: Flashing when synced with SR-R4.



Media remaining indicator flashing



Media Remain (Near End)



The remaining media on the SR-R4 has reduced to the
Near End value setting.

REC: Flashing when synced with SR-R4.



Media remaining indicator flashing   rapidly



Media Remain (End)



The remaining media on the SR-R4 has reduced to the
End value setting.

DIAGNOSIS: Flashing red rapidly



Displays same message as self diagnostics field in a dialog.



Temperature NG!
Shutdown Camera

The internal camera temperature has reached its limit.
Turn off the camera power supply.
DIAGNOSIS: Flashing red rapidly


Fan1 NG!



Fan1 NG!

Fan 1 near the top panel stopped.
DIAGNOSIS: Flashing red rapidly


Fan2 NG!



Fan2 NG!



Fan 2 near the top panel stopped.


DIAGNOSIS: Flashing red


Sync Error


Sync Error


A sync error occurred.



DIAGNOSIS: Lit red DOCK: Lit yellow




Optical Level Care





Optical Level Care



The optical level of the Recorder connector has reduced
to caution level.
Clean the Recorder connector or replace the optical
module.

DIAGNOSIS: Lit red DOCK: Lit red





Optical Level NG






Optical Level NG




A light reception error occurred with the Recorder
connector.
Immediately, clean the Recorder connector or replace
the optical module.


DIAGNOSIS: Lit red DOCK: Not lit



Optical Level No Input



Optical Level No Input



No signal is input on the Recorder connector.




DIAGNOSIS: Lit red

CRCC Error occurred


CRCC Error occurred

A Cyclic Redundancy Check Code (CRCC) error
occurred with the Recorder connector. Clean the
recorder connector.


Mounting the SR-R4
Always turn off the camera power supply when mounting the SR-R4.
The recorder connector for connecting the SR-R4 is an optical connector. Attach the connector cap on the optical connector when not connected to an SR-R4 to protect the connector. After removing the cap, store it in the position shown in the following figure for safekeeping.
When mounting the SR-R4, fix the camera head on a tripod in advance to keep the camera head stable.
When the camera is used with the SR-R4 docked, make sure that the camera is securely fixed and stable so that it will not fall over.
Attaching a Filter
1. Place the filter template (metallic disc) on the gel filter, then trim the filter around the edge of the filter template.
2. Remove the ring from the filter holder, place the filter on the ring, and then attach the holder.
3. Align the protrusion on the mounting tool with the notch on the filter holder, then insert the holder into the tool.
4. Align the notch on the filter mount with the protrusion on the filter holder, insert the mounting tool onto the filter mount, and then turn clockwise until it clicks into place.
5. Pull the mounting tool straight off. The mounting tool separates from the camera, and the filter is mounted in place.
To remove the filter
1. Align the protrusion on the mounting tool with the notch on the filter holder, then press the tool onto the filter mount. Press the tool until it clicks into place.
2. Rotate the mounting tool counterclockwise, then lift the tool off the camera.
The filter holder is removed with the mounting tool.