REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Showing posts with label BRANDT. Show all posts
Showing posts with label BRANDT. Show all posts

Monday, 25 March 2019

HOW TO ENTER SERVICE MODE TO BUSH - BAIER - BANG & OLUFSEN - BEKO - BLACK DIAMOND AND BRANDT TELEVISIONS

HOW TO ENTER SERVICE MODE TO BUSH - BAIER - BANG & OLUFSEN - BEKO - BLACK DIAMOND AND BRANDT TELEVISIONS





Universal remote code to check with Bush TV is [1056]

BUSH _ BAIER _ BANG & OLFUSEN _ BEKO _ BLACK DIAMOND _ BRANDT  
BUSH RF6694D
  • Go to Bush TV main menu.
  • Press simultaneously MUTE and INFO button.
  • Change and select parameter press colored button To save  settings press ok
  • Press menu to exit from service mode
BUSH ITV2112
  • Open remote control cover, connect pin 10 and 17 of Samsung IC.
  • Use colored button to select and volume to change value settings.
  • To store press OK.
  • To Exit press ‘0’ key.
BUSH WS66-7673
  • Go to main menu and input [4 7 2 5]
  • Use colored button to select and change settings.
  • To save settings press OK.
  • To exit from service menu press Menu button.
BRANDT TX807 _ ITC008
  • TV in standby mode.
  • Shut off TV using main switch button / no electric activity in your television.
  • Next press [TXT] button and hold it.
  • Switch ON your television using main switch.
  • Press program + or program - to select and volume + or volume - to change the data value value.
  • To save and exit press power button on remote control.
BRANDT TX91 _ TX91G
  • TV in standby mode.
  • Shut off TV with main switch.
  • Press VT button on remote control and hold the key.
  • Switch on TV with main switch.
  • Release VT button and press VT buton again.
  • Service menu mode load in 0.1 seconds.
  • To change and select press program and volume button on remote control.
  • To save and exit press power button on remote control
BLACK DIAMOND BDS1451UK
  • Press Menu and press following key [4, 7, 2, 5.]
  • Factory mode will load in 0.1 second.
  • Use Red, Green, Blue, Yellow button to select and change.
  • To save settings press Ok button.
  • To exit from factory mode press MENU button.
BEKO TV22.1
  • Select menu and enter key 9, 3, 0 1
  • To select parameter press program up or program down.
  • To change the data value press volume up to increase and volume down to decrease.
  • Press Power button on the remote control to save and exit.
BAIER TV4K28MFV
  • Factory mode button is hidden button located below STOP button, left to  cancel button.
  • Press Red button go to next menu
  • Press program up and down to select item.
  • Press volume up and down to change value settings. 
  • To Save and exit press P.P.
BANG & OLFUSEN LX4500 _ LX5500 _ LX5000 _ LX6000
  • TV ON Press TV on remote control and short the pin service mode plugged p700 on PCB14.
  • Select press p+/p- button and change value pres v+/v- button.
  • Save change and exit press STOP button on remote control.

Monday, 25 February 2019

THOMSON - 20LCDB03B - TELEFUNKEN - SABA_FERGUSON - BRANDT - SERVICE MODE


THOMSON - 20LCDB03B - TELEFUNKEN - SABA _ FERGUSON - BRANDT - SERVICE MODE


APPLICABLE TO - THOMSON - 20LCD B3B - TELEFUNKEN  - SABA - FERGUSON - BRANDT TVs

ENTERING SERVICE MODE {supports 15", 20" and 20" bi-sonic.}

  • Press the "Menu" button and the screen will appear.  "Overview" below as Figure Overview OSD.
  • Press "Info" button and "1", "0" and "3" buttons step by step to enter Service Mode.  Service mode will appear on the screen.
  1. Color Temp:  P-N means 'Normal' on Ypbpr1, V-N means 'Normal' on video mode.  Each item decide different gamma curve.  
  2. Red drive, Green drive and Blue drive, means gamma RGB gain control by scaler.
  3. Red-offset, Green-offset and Blue-offset means gamma RGB offset.
  4. Reset to Default => Press "OK" button will load all default value on user OSD.
  5. Calibration => Press this both guide to calibrate A/D converter, white/black level on PC input.  Also guide to calibrate A/D converter Pb,Pr offset on YpbPr input.  
  6. Auto turn on => Toggle On/Off control auto turn On.  This function for factory burn-in sets.  Only active on selection PC input then main power Off.
  7. Green lable => Tuner S/W version, time when compiling S/W model name, main S/W version.
  8. OSD position => OS Didplay posistion selection.
  9. Factory Save => Press 'OK' to save all parameters on service mode.
  10. Auto Adjustment => Auto adjustment new timing (Position, Phase etc).  Only active on PC mode.
  11. Video int Gain => This slider bar used to align brightness spec: of video mode.  larger value bring to brighter.  Control by video decoder VPV3230.
  12. Color => Adjust color saturation.  Same function on User OSD.  Control by video.
  13. Tuner set V-Level => not used.
  14. Tuner Get V-Level => not used.
  15. Set First Installation => Enable means TV will pop-up installation OSD at next Power On.
  16. Tuner Set Factory Programs => not used.
  17. Exit =. To Exit from Service Mode.
  18. PW Gamma => Gamma curve selection.  'Automatic' means, pick up proper gamma curve automatically when user choose Normal, Warm and Cool. Value change is not recommended.
  19. Scale Mode => Screen ratio selection.
  20. VPC AGC On => Turn On video decoder "Auto gain control" {Analog input leve adjustment}
  21. VPC AGC Off => Turn OFF Video decoder "Auto gain control".
  22. HV Lock sensitivity => Tuner HV sync sensitivity.  Value chang not recommended. Fake program be detected or Real Program be skipped.
  23. Color Delay => Color timing delay, which only impact on video mode.  For development only.  Value change not recommended. 
  24. Audio gain => not used.
  25. Pb offset => Adjust Pb offset on YpbPr input.
  26. Pr offset => Adjust Pr offset on YpbPr input.
  27. Enter PW 1230 adjustment page => De interlacer parameters control.  For development only.  Value change is not recommended.
  28. Video Format => Select video standard.  Force to 'Auto'.
  29. Default language => Set default language.  Same function on user OSD.
  30. RGB filter => Sharpness filter for PC port of scaler.  Impact on PC and YpbPr input.
  31. Video filter => Sharpness filter of video of scaaler.   Impact on TV Video and YcbCr.
  32. Monitor sync => Force to "On". So that video format can auto detection.
  33. Reset all NVRAM => Press "OK" will reset all parameters is on service mode, including color temperature settings, brightness settings...etc.
  34. Test pattern => Display test pattern which generate by scaler. Only active on PC source. 
  35. H.Position => Adjust Horizontal Position when PC source in.
  36. V.Position =>Adjust Vertical Position while PC source in.
  37. Left Time => Left time means the time added by standby + TV On.  The right item display the time of TV-On only.
  38. Project code => As title.
  39. Panel resolution => As title.
  40. NvRam ver => display EEPROM data version.
  41. HVX Res/Hfreq => Timing information.  Resolution and H clock.
  42. HXV Total => Timing information.
  43. Mode Num => Timing information. Sequence of timing chart.
  44. DCLK => Timing information Data Clock.  These 4{41,42,43 & 44} items above are for development check only.  
  45. Factory Save => Saves factory parameters.
  46. Green Label => Display tuner S/W version

Wednesday, 20 February 2019

BUSH WS66-7673 BRANDT - TX91 - TX91G SERVICE MODE

BUSH WS66-7673 BRANDT - TX91 - TX91G SERVICE MODE




BUSH WS66-7673 SERVICE MODE.

  • Enter the Main Menu.
  • Key in digits [4,7,2,5] by the remote control.
  • Service mode will be displayed.
  • Use colored buttons to select items and to adjust the data value.
  • Press "OK' button to save settings.
  • Press "Menu" button to 'Exit' service mode.
BRANDT - TX91 _ TX91G
  1. Make the TV to 'Standby' mode.
  2. Shut OFF the TV by its front panel Power Switch.
  3. Press and Hold 'VT' button on the remote control, and switch ON the TV by its Front Panel Power Switch.
  4. Release the 'VT' button, and press the "VT' button again.
  5. Service mode will be displayed.
  6. To call an item to adjust, use Prog(+) / Prog(-) buttons on the remote control.
  7. To adjust the data value to selected item, use Vol(+) / Vol(-) buttons on the remote control.
  8. Press "Power' button on the remote control to save and 'Exit' Service Mode

BLACK DIAMOND - BDS 1451UK & BRANDT - TX807 / ITC 008 _ SERVICE MODE

BLACK DIAMOND - BDS 1451UK & BRANDT - TX807 / ITC 008 _ SERVICE MODE




BLACK DIAMOND  BDS-1451UK
  • Press "Menu" button.
  • Enter digits [4 => 7 => 2 => 5] by the remote control.
  • Factory mode screen will be displayed.
  •  Use "Red / Green / Blue and Yellow" buttons  to select and change items.
  • To "Exit" Service mode, press "Menu" button.
BRANDT TX 807 & ITC 008
  1. Set the TV to 'Standby' Mode & Switch Off' the set. {power ON the set by its front panel power switch, and press power button on the remote control to make the set to standby, and then Switch it OFF}
  2. Press and Hold "TXT" button on the remote control, and Switch ON the TV by its main Power Switch.
  3. Set will come back ON with 'Service Mode' option.
  4. To call an item to adjust, press 'Prog + / Prog -" buttons on the remote control.
  5. To adjust the data value to selected item, use "Vol + / Vol -" buttons on the remote control.
  6. To "Exit" service mode, press "Power" button on the remote control.

Tuesday, 12 February 2019

BRANDT FERGUSON SABA TELEFUNKEN THOMSON POWER SUPPLY DESCRIPTIONS 50HZ - 100HZ CHASSIS USING TEA 2261 IC AS POWER CONTROL WORKING PRINCIPLES.

  BRANDT FERGUSON SABA TELEFUNKEN THOMSON POWER SUPPLY   DESCRIPTIONS   50HZ - 100HZ CHASSIS USING TEA 2261 IC AS POWER CONTROL   WORKING PRINCIPLES. 



50Hz CHASSIS



100Hz CHASSIS






GENERATION OF INTERNAL REFERENCES AND POWER SUPPLIES

                            The power supply at Pin 16 comes from:

     On start-up, half-wave rectification of the mains by the mesh RP025, CP054, and a diode of the bridge rectifier. In Standby Mode, winding 9, 8 of LP020 (fly-back mode). 12 V obtained by rectification (DP050, CP054) is applied to regulator IP050 (7809 applied to Diode DP051), which supplies 9 V via DP052.  In Steady-State, winding 9, 10 of LP020 (fly-back mode). Rectification by DP053 supplies a voltage of about 11 V. 

     Note that in this case Diode DP052 is blocked, and disconnects circuit IP02.
Resistor RP054 delivers the power supply to the final stage (Pin 15), and sets its maximum current.  The circuit supplies several voltages and service signals according to changes in the direct current voltage at Pin 16.  As soon as +Vdc reaches approximately 4V5, an internal reference of +2V5 is generated. For +Vdc & 5V5, a RESET pulse is produced.  When +Vdc reaches 10V3 (Vdc start), enabling of an internal power supply Vdc int = 5 V. This stabilized voltage allows the circuit to perform well in a wide voltage range on Pin 16.  This threshold also triggers the passage to high state of Vdc off, thus enabling the interlock and limit management logic, and authorising pulse output from Pin 14 (as long as +Vdc remains higher than +Vdc stop, i.e. 7V4 typ.).  For Vdc of 15V7 typ., passage to high state of Vdc max, and interlocking of the circuit by the interlock and limit management logic.

OPTIONS

SWITCHING OF START-UP POWER SUPPLY:

     On 100-Hz chassis, a thyristor (TP025) is added in series with Resistor RP025.  When mains power is applied, a current from the 300 V via the RP028, RP030 through 32 resistor network energizes the thyristor. The thyristor then channels the CP054 charging current.  When the power supply starts up, a voltage of 9V6 appears at the output of Regulator IP050 and saturates Transistor TP026. With its gate then earthed, the thyristor de-energizes the next time the mains alternation is inverted.  This layout reduces the consumption by 0.7W.

LOW-POWER SWITCH

     A low-power switch can be connected in series with Resistor RP025 to replace the classic mains switch.  In operation, this switch connects RP025 via Resistor RP55 to Pin 16 of IP60.  In Off position, this switch switches Pin 16 of IP060 to earth via Resistor RP035 and Diode DP035.  Zener Diode DP054 limits the voltage to the terminals of CP54 when Off.


OUTPUT STAGE

     The output stage of the TEA2261 consists of a push-pull.  It supplies the basic current for control of TP060, and then channels the reverse locking current caused by the discharging of CP040.  In the conduction phase, Resistor RP054 limits the polarization current.  TP060 SWITCHING CIRCUITS resistors RP029 through RP032 pre-charge CP040 as soon as power is switched on, to ensure an adequate reverse locking current during the start-up phase and at the beginning of each burst. Self-induction coil LP040 sets the dl/dt of the control current reversal.  The circuit DP022, CP023, RP022 slows the rise in collector voltage of TP060 when it is blocked, to ensure minimum dissipation through switching, and to limit the overvoltage peak. To do this, it is assisted by the secondary assembly DP113, LP112, RP112, CP112, and DP112.

Secondary Voltages

The secondary wingdings produce five direct voltages:

     +USYS which can be between 127 and 140 volts, according to chassis, and according to the winding connector selected (19 through 22 via jumpers JP914 through 917).

     +US and -US, symmetric power supplies with specific earth distributed to the audio stage via a cable (from BP120).  +UVERT, vertical stage power supply voltage. Also applied to the regulator circuit, IP30, and causes the polarization of the base of TV002 (IV001 power supply).  +U7V, voltage supplying the switched 5 V.  In Standby Mode, the 10VSTBY is produced by Regulator IP130 and Diode DP133. In Steady State, the 13 V from the EHT takes over via Diode DP134.  The switched 5 V is obtained at Pin 8 of IP140 (switched by voltage +U13, Pin 4) on 50-Hz stereo chassis, while a transistor, TP146, handles this regulation task for 50-Hz Dolby and 100-Hz chassis.

Secondary Regulation

     This mode is adopted as soon as Steady-State Mode begins. It regulates voltage USYS.  A fraction of USYS, tapped off by divider bridge RL082, RL081, and RL080,
is applied to Pin 31 of IV001 (SMPS IN).  This information is compared to an internal reference whose value can be adjusted according to operating mode (USYS adjusted in 64 steps within a 16-V range).  A strobe signal at line frequency with a variable duty cycle is available on Pin 37 (SMPS OUT).  This signal is applied to galvanic isolating transformer LP070 via Transistor TP161.  A soft start circuit is associated with the production of the command strobe signal. (CV246, Pin 17; when power is applied to circuit IV001, it is charged to 5V5 in 900 ms. The network RV242, CV242, CV243 limits the pass band of the entire regulating loop to 300 Hz.  On 100-Hz chassis, Transistor TP162 controls transformer degassing   In the event of irregularities on the secondaries or in the time bases, the interlock circuit forces the BREATHING line to low state (Pin 28 of IV001).  The regulating and time base commands are then stopped. If the error persists after two more start-up attempts by IV001, the TV goes into Standby Mode.

Power Supply Interlocks

     Overloads and short circuits are detected by analysing the primary current in the emitter resistor of TP060 (input at Pin 3 of circuit IP060).  The sensitivity of this stage was increased in Standby Mode to detect errors in the low-voltage secondaries (RP065, TP027, and RP059). For this reason, when an incident occurs in Steady State on a secondary other than U SYS, it is necessary to go to Standby Mode to trigger the interlock.  
  •  An overload or short circuit on voltages +U VERT or +10 V STBY leads to:


power supply VCC1 of the regulation and sweep circuit (IV001) disappearing.  
 An overload or short circuit on +US causes TP190 and TP170 to conduct.  This forces the breathing interlock input of the regulation and sweep circuit (IV001) to be triggered by a low level.  
  •  An overload or short circuit on: 
  • US causes DP190 and TP170 to conduct, and triggers the IV001 interlock.  In the event that external speakers with too low an impedance value are connected (Dolby versions), or when incidents occur on the +5 V, simply shut off the sweep to remove the overload:


·         Excessive current in Resistor RP130 causes TP129 and TP170 to conduct, and triggers the IV001 interlock (audio mute).
·         A short circuit on the +5 V blocks TP175 through the action of DP178, and causes TP170 to conduct (see sweep interlocks), causing the IV001 interlock
             to trigger and the +13 V to disappear.


Detection of Mains Power Failure

     In the event of mains power failure, the micro controller must be informed promptly so that the data in the NVM (IR003) can be saved, and to avoid a plop in the speakers (sound mute).
    To do this, POWER FAIL has a rising edge in the event of mains power failure in ON Mode, and a falling edge in the event of mains power failure in Standby Mode.
    The signal is received by the management circuit via the INTERRUPTION input at Pin 55. Transistor TR091 produces a low mute level when the phenomenon occurs in ON Mode.
    The negative voltage rectified in Forward Mode by Diodes DP151/152 is an image of the mains voltage. It blocks TP152 in ON Mode. TP150 and TP145 are blocked. TP167 is saturated, and the POWER FAIL line has a low level.

     When the mains falls below 160 Vac, TP152, TP150, and TP145 conduct, TP167 generates a rising edge on the POWER FAIL line by blocking off.  In Standby Mode, because voltage +UVERT goes from 23-26 V to 14 V, the RP150/151 network saturates TP150, TP145 conducts and blocks TP167, and the POWER FAIL line has a high level.
When mains power breaks down, the decrease in 10VSTBY saturates TP166 and TP167, and the POWER FAIL line has a falling edge.