REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Saturday, 2 February 2019

SONY XBR43X830C, SONY XBR49X835C – LCD TV ERROR CODES, LED BLINKING CODES, SERVICE MODE AND ADJUSTMENTS

Sony XBR43X830c, Sony XBR49X835C – LCD TV Error codes, LED blinking codes, Service mode and adjustments

Sony XBR-43X830C Black RMT-TX100U (UC2) US/CND
XBR-49X830C Black RMT-TX100U (LA1) , MEXICO, (UC2), US/CND, 
XBR-49X835C Black RMT-TX100B (LA8) CHILE, PERU, VENEZUELA, (AR4), ARGENTINA, (CR1), COSTA RICA, (ECU), ECUADOR
Silver RMT-TX100B (BR6)-BRAZIL
XBR-49X837C Black RMT-TX100B (CO1) – COLOMBIA
These units contain a self-diagnostic function. If an error occurs, the Smart Core Red LED will automatically begin to flash.
The number of times the LED flashes translates to a probable source of the problem.
A definition of the Smart Core Red LED flash indicators is listed in the instruction manual for the user’s knowledge and reference.
If an error symptom cannot be reproduced, the remote commander can be used to review the failure occurrence data stored in memory to reveal past problems and how often these problems occur.

DIAGNOSTIC TEST INDICATORS
When an error occurs, the Smart Core Red LED will flash a set number of times to indicate the possible cause of the problem.
If there is more than one error, the LED will identify the first of the problem areas.
Result for all of the following diagnostic items are displayed on screen.
If the screen displays a “0”, no error has occurred.
SELF DIAGNOSTIC SCREEN DISPLAY
Format of error time stamps
YY MM DD hh mm ss (in UTC)
Example:
120823132523 -> Aug 23 2012 13:25:23 UTC
* Only when time is set, an error time stamp is saved.
•Panel Operation Time is recorded every 30 min, but Total Operation Time is recorded every 1 hr.
Therefore, the panel op. time might become larger than the total op. time.
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confirmed, it is possible to bring up past occurrences of failure for confirmation on the screen:
To Bring Up Screen Test
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen.
After you have completed the repairs, clear the result display to “0”.
Clearing the Self Check Diagnostic List
Panel operation time : Press the Channel 7 => Channel 0 .
Exiting the Self-diagnostic screen
To exit the Self Diagnostic screen, Power off & on or Push the <Home> button.
Adjustments
1) Turn on the main power switch to set in standby mode.
2) Press the buttons on the remote commander in the following sequence with each interval within 1 sec, then the service mode will be set.
How to use the remote commander
SOFTWARE VERSION
In Service Mode, select “Model Information”, press “Enter” or “→ ” button to enter Status Information.
Press “Enter” or “Return” button to return to Service Mode.
SERIAL NUMBER EDIT (1)
1) In “Service Mode”, select “Model Information” by pressing “↑” or “↓” then pressing “Enter” or “→” button to enter inside.
2) Select “Serial Number Edit” by pressing “↑” or “↓” button then pressing “Enter” or “→” button
3) Press “↑” or “↓” to input numbers.
4) After user input data, press <Enter> .
• Pop-up dialog appear to confirm input data correct
• Serial Number can be set ONLY ONCE
5) Press “→” or “←” button to select YES or NO. Select YES if input data is correct. Select NO if
input data is incorrect. Press <Enter> to save answer.
SERIAL NUMBER EDIT (2)
If YES is selected, the input data is saved into EEPROM.
SERIAL NUMBER EDIT is grayed out and the serial number that has been input is displayed.
User will not able to edit anymore.
If NO is selected, the input data is not saved into EEPROM.
The serial number that has been input is displayed.
User can still edit the Serial Number
MODEL NUMBER SETTING
1) In “Service Mode”, select “Model Information” by pressing “↑” or “↓” then pressing “Enter” or “→” button to enter inside.
2) Select “Model Number Setting” by pressing “↑” or “↓” button then pressing “Enter” or “→” button.
3) Press “↑” or “↓” arrow key to scroll Product Name Candidate.> (e.g. KDL-40X500B CO1,KDL-40X500C BR6)
4) Select one Product Name from the list, press <Enter> will pop dialog to inform user to confirm data. Model dependent settings will be overwritten into EEPROM.
WB ADJUSTMENT
When main board or panel is replaced this adjustment should be done.
In “Panel/PQ” service mode.
a. Go to “WB Adjustment” category by “↑” or “↓”
b. To select “WB Adjustment”, press “→” button.
c. To change data , press “←” or “→” on remote commander.
WB/MURA/CUC DATA TRANSFER
 Apply when main board or panel is replaced.
1. In “Panel/PQ” service mode.
a. Go to “WB/Mura/CUC data transfer” category by “↑” or “↓”
b. To select “WB/Mura/CUC data transfer”, press “→” button.
c. To change data , press “←” or “→” on remote commander.
2. In “WB/Mura/CUC data transfer”.
a. Select “WB/Gamma data transfer” by pressing “↑” or “↓” on remote commander.
b. To change the items, press “←” or “→” on remote commander and press “Enter” button.
Selectable items are:
0. SoC to T-con
1. T-con to SoC
2. Not action
c. Select “[start]” and press “Enter” button to start transfer.
HDD PERFORMANCE CHECK
1. In “Service Mode”, select “General Setting” by pressing “↑” or “↓” then pressing “Enter” or “→” button to enter inside.
2. Select “HDD Performance check ” by pressing “↑” or “↓” then pressing “Enter” or “→” button to enter inside
3. A message "Please wait ..." is displayed during performance check processing.
4. Result OK or NG will be displayed after performance of HDD is checked
HDD RE-REGISTRATION
1) In “Service Mode”, select “General Setting” by pressing “↑” or “↓” then pressing “Enter” or “→” button to enter inside.
2) Select “AAA” by pressing “↑” or “↓” then pressing “Enter” or “→” button to enter inside.
3) Result OK or NG will be displayed after HDD re-registration is succeed/failed.