ELECTROLUX EWM 2500 - EWM2100 Top loader Washing machines error codes Test mode and module description
ELECTROLUX EWM2500 - EWM2100
Activate the demo - program
1. Access to demo program
Switch off the appliance.
Keep buttons 6 and 5 pressed in together and rotate the programme selector three positions to the right.
Keep both selected keys pressed for about 2 seconds.
You can select the individual programs and the associated option keys by using the program selector switch. The key start/pause is disabled.
The demo program will remain in the memory even if the appliance is switched Off.
Switch off the appliance.
Keep buttons 6 and 5 pressed in together and rotate the programme selector three positions to the right.
Keep both selected keys pressed for about 2 seconds.
You can select the individual programs and the associated option keys by using the program selector switch. The key start/pause is disabled.
The demo program will remain in the memory even if the appliance is switched Off.
2. Abandoning the demo program
Switch off the appliance.
Keep buttons 6 and 5 pressed in together and rotate the programme selector three positions to the right.
Keep both selected keys pressed for about 2 seconds.
Switch Off the appliance to deactivate the demo program.
Switch off the appliance.
Keep buttons 6 and 5 pressed in together and rotate the programme selector three positions to the right.
Keep both selected keys pressed for about 2 seconds.
Switch Off the appliance to deactivate the demo program.
Activate the electronic-test
1. Access to the electronic-test
Switch off the appliance.
Hold buttons 6 and 5 pressed simultaneously and turn the program selector one position to the right.
Keep both selected keys pressed for about 2 seconds.
Hold buttons 6 and 5 together and pressed again.
Switch off and on the appliance
The display indicates ELE
The electronic-test it running
Filling till 1. Niveau
Movement with 50 1/min.
Heating up to max. 50°C or 20min duration.
Switch off the appliance.
Hold buttons 6 and 5 pressed simultaneously and turn the program selector one position to the right.
Keep both selected keys pressed for about 2 seconds.
Hold buttons 6 and 5 together and pressed again.
Switch off and on the appliance
The display indicates ELE
The electronic-test it running
Filling till 1. Niveau
Movement with 50 1/min.
Heating up to max. 50°C or 20min duration.
2. Abandoning the electronic-test
Switch off the appliance.
Switch off the appliance.
Activate the operating time
1. Access to the operating time
Switch off the appliance.
Keep buttons 6 and 5 pressed in together and rotate the programme selector five positions to the right.
Keep both selected keys pressed for about 2 seconds.
2. Abandoning the operating time
- Switch off the appliance.
Switch off the appliance.
Keep buttons 6 and 5 pressed in together and rotate the programme selector five positions to the right.
Keep both selected keys pressed for about 2 seconds.
2. Abandoning the operating time
- Switch off the appliance.
BUTTON POSITION
Electronic Module Description
The electronic module, including the uP, controls various functions and is placed in a protective housing. It is the communication interface between the user and the appliance. It consists of:
The option buttons and the multifunction display LCD.
The programselector with 15 or 21-positions.
The time display and the alarm identification.
The “Start/Pause” button.
The electronic module, including the uP, controls various functions and is placed in a protective housing. It is the communication interface between the user and the appliance. It consists of:
The option buttons and the multifunction display LCD.
The programselector with 15 or 21-positions.
The time display and the alarm identification.
The “Start/Pause” button.
Functions:
Taking data of the selected cycle programs through the module.
Water level control (antifoam, overflow level) in the tub; the level is recognized by the analog pressure switch.
Cycle temperature control by a NTC sensor.
Power supply of the heating element.
Power supply of the drive motor (EWM2100) and control of its speed by the tachymetric generator.
Control of the motor control board (EWM2500).
Control of water inlet valves.
Control of drain pump, circulation pump, door lock and DSP (drum self position). In case of a power failure the module saves the just paused cycle.
When the power supply to the appliance is restored again, the cycle starts where the program was paused.
Taking data of the selected cycle programs through the module.
Water level control (antifoam, overflow level) in the tub; the level is recognized by the analog pressure switch.
Cycle temperature control by a NTC sensor.
Power supply of the heating element.
Power supply of the drive motor (EWM2100) and control of its speed by the tachymetric generator.
Control of the motor control board (EWM2500).
Control of water inlet valves.
Control of drain pump, circulation pump, door lock and DSP (drum self position). In case of a power failure the module saves the just paused cycle.
When the power supply to the appliance is restored again, the cycle starts where the program was paused.
Motor
The motor is directly phase-controlled via
triac from the control electronics.
Relays K2, K3 are responsible for commuting the sense of rotation.
Field switching (if any) is controlled by relay K4.
Speed is monitored by tachometer generator g1 and controlled by control electronics.
Integral overheat protection disconnects the motor from power supply at 115°C
Relays K2, K3 are responsible for commuting the sense of rotation.
Field switching (if any) is controlled by relay K4.
Speed is monitored by tachometer generator g1 and controlled by control electronics.
Integral overheat protection disconnects the motor from power supply at 115°C
Safety
If the triac for the motor is in short-circuit, or if the tachometer generator is interrupted, 4 trials are executed in intervals of 5 minute each.
After a break of 20 minutes, the fifth and last trial is started. If the motor does not run this time, the programme is aborted.
If the triac for the motor is in short-circuit, or if the tachometer generator is interrupted, 4 trials are executed in intervals of 5 minute each.
After a break of 20 minutes, the fifth and last trial is started. If the motor does not run this time, the programme is aborted.
Fault indication by multi functions
display LCD
E11
Type of fault
No water filling
Water tap closed
Valve does not open / interruption
Valve flow rate to low
Air trap system leaking
Cable defect
Electronic defect.
Water tap closed
Valve does not open / interruption
Valve flow rate to low
Air trap system leaking
Cable defect
Electronic defect.
Remedy
Open tap
Change the valve
Clean filter
Replace air trap
Cable pressure switch and electronic
Replace electronic
Change the valve
Clean filter
Replace air trap
Cable pressure switch and electronic
Replace electronic
E13
Type of fault
Not enough water
Wrong drain pipe position
Valve flow rate to low
Inlet valve defect
Pressure switch defect
Hose for pressure switch leakage or blocked
Wrong drain pipe position
Valve flow rate to low
Inlet valve defect
Pressure switch defect
Hose for pressure switch leakage or blocked
Remedy
Check the drain pipe position
Clean filter
Replace inlet valve
Replace pressure switch
Check the hose for the pressure switch
Clean filter
Replace inlet valve
Replace pressure switch
Check the hose for the pressure switch
E21
Type of fault
No draining
Pump blocked / not w orking
Pump interrupted
Reduced pump output rate
Pressure switch defect
Pressure sensor defect
Electronic defect
Pump blocked / not w orking
Pump interrupted
Reduced pump output rate
Pressure switch defect
Pressure sensor defect
Electronic defect
Remedy
Remove foreign object
Replace drainpump
Check draining system
Replace pressure switch
Replace pressure sensor
Replace electronic
Replace drainpump
Check draining system
Replace pressure switch
Replace pressure sensor
Replace electronic
E23
Type of fault
Incongruence between drain pump and electronic
Remedy
Replace drain pump,
Cable drain pump
Cable drain pump
E24
Type of fault
Drain pump triac sensing failure 1 Input
voltage always 0V or 5V
Remedy
Replace electronic
E31
Type of fault
Pressure sensor defect
Frequency of the pressure sensor out of limit
Cable interrupted
Frequency of the pressure sensor out of limit
Cable interrupted
Remedy
Replace pressure sensor
Replace cable
Replace cable
E32
Type of fault
Calibration problems pressure sensor
After initial calibration the water level not
in between 0 - 66mm and anti boil level off
After initial calibration the water level not
in between 0 - 66mm and anti boil level off
Remedy
Open tap
Replace inlet valve
Clean filter
Replace air trap, Replace pressure sensor
Replace inlet valve
Clean filter
Replace air trap, Replace pressure sensor
E33
Type of fault
Incongruence between pressure sensor
and anti boil level 1
Fault has to be for a time longer than 60 sec.
and anti boil level 1
Fault has to be for a time longer than 60 sec.
Remedy
Replace pressure sensor
Replace cable
Replace air trap
Replace cable
Replace air trap
E33
Type of fault
Incongruence between pressure switch Niv.1
and anti boil level 1
Fault has to be for a time longer than 3 sec.
and anti boil level 1
Fault has to be for a time longer than 3 sec.
Remedy
Replace pressure switch, Replace electro
Replace heating element
Cable pressure switch and electronic
Replace heating element
Cable pressure switch and electronic
E34
Type of fault
Incongruence between pressure sensor
and anti boil level 2
Fault has to be for a time longer than 60 sec.
and anti boil level 2
Fault has to be for a time longer than 60 sec.
Remedy
Replace pressure sensor
Replace cable
Replace air trap
Replace cable
Replace air trap
E34
Type of fault
Incongruence between pressure sensor
and anti boil level 2
Fault has to be for a time longer than 60 sec.
and anti boil level 2
Fault has to be for a time longer than 60 sec.
Remedy
Replace pressure sensor
Replace cable
Replace air trap
Replace cable
Replace air trap
E35
Type of fault
Safety level (Pressure sensor)
Level has to be 300mm for a time of more than 15 sec
Drain pump will be activated until level is below 120 mm
Level has to be 300mm for a time of more than 15 sec
Drain pump will be activated until level is below 120 mm
Remedy
Replace pressure sensor
Replace cable
Replace air trap
Replace cable
Replace air trap
E35
Type of fault
Safety pressure switch on for a time longer
than 15 sec.
Remedy
Replace inlet valve, Replace electronic
Air trap system leaking
Replace pressure switch
Cable pressure switch and electronic
Air trap system leaking
Replace pressure switch
Cable pressure switch and electronic
E36
Type of fault
Antiboil 1 sensing failure 1 Input voltage always
0V
Remedy
Replace electronic
E37
Type of fault
Antiboil 2 sensing failure 1 Input voltage
always 0V or 5V
Remedy
Replace electronic
E37
Type of fault
Pressure sw itch Niv.1 sensing failure Input volt.
always 0V or 5V
Remedy
Replace electronic
E38
Type of fault
Air trap blocked
No pressure differences detected
No pressure differences detected
Remedy
Change airtrap
Clean airtrap
Clean airtrap
E39
Type of fault
sensing failure Input volt. always 0V
Remedy
Replace electronic
E3A
Type of fault
Heating element relay defect
Remedy
Replace electronic
E41
Type of fault
Lid open
Door lock defect
Cable defect
Electronic defect
Door lock defect
Cable defect
Electronic defect
Remedy
Replace door lock
Replace cable
Replace electronic
Replace cable
Replace electronic
E42
Type of fault
Door lock defect
Door is unlocked during the cycle Tout 15 sec
Door is not unlocking at the end of cycle Tout 4 min
Door is unlocked during the cycle Tout 15 sec
Door is not unlocking at the end of cycle Tout 4 min
Remedy
Replace door lock
Replace cable
Replace electronic
Replace cable
Replace electronic
E43
Type of fault
Door lock triac defect
Remedy
Replace door lock, Replace cable
Replace electronic
Replace electronic
E44
Type of fault
Door lock sensing failure Input voltage always
0V or 5V
Remedy
Replace electronic
E51
Type of fault
Motor triac short circuit
Motor cable short circuit
Motor cable short circuit
Remedy
Replace cable
Replace electronic
Replace electronic
E52
Type of fault
No signal from tacho generator
Motor blocked
Motor cable defective
Motor blocked
Motor cable defective
Remedy
Replace tacho gnerator
Replace motor
Replace cable
Replace electronic
Replace motor
Replace cable
Replace electronic
E53
Type of fault
Motor triac sensing failure Input voltage always
0V or 5V
Remedy
Replace electronic
E54
Type of fault
Motor relay defect
Remedy
Replace electronic
E58
Type of fault
Motor phase current goes above threshold
(>4,5A)
Remedy
Replace motor, replace cable
Replace motor control board
Replace motor control board
E59
Type of fault
No tacho signal for 3 seconds after new speed
target
different from zero
different from zero
Remedy
Replace motor, replace tacho generator
Replace motor control board, replace cable
Replace motor control board, replace cable
E5A
Type of fault
Heat Sink temperature goes above threshold
(88°C)
Remedy
Replace motor control board
E61
Type of fault
Insufficient heating
Maximum heating time expired
NTC defective
Heating element defect
Connection heating element interrupted
Maximum heating time expired
NTC defective
Heating element defect
Connection heating element interrupted
Remedy
Replace NTC
Replace heating element
Replace cable
Replace heating element
Replace cable
E62
Type of fault
Overheating:
Temperature greater 88°C for a time longer than 5 min
NTC defective
Cable defective
Temperature greater 88°C for a time longer than 5 min
NTC defective
Cable defective
Remedy
Replace NTCReplace heating element
Replace cable