HCD-SH2000 Sony MINI HI-FI COMPONENT SYSTEM – Test Mode- CD mechanism Exploded view
HCD-SH2000 is the tuner, USB,
CD and amplifier section in FST-SH2000/LBT-SH2000. CD Mechanism Type:
CDM86B-DVBU101. Optical Pick-up Name: KHM-313CAB/C2NP
Amplifier section: The following are measured at AC 120 V - 240 V, 50/60 Hz
Power output (rated)
High channel - 300 W + 300 W (at 4 Ω, 1 kHz, 1% THD)
Low channel - 300 W + 300 W (at 4 Ω, 100 Hz, 1% THD)
RMS output power (reference)
High channel - 500 W + 500 W (per channel at 4 Ω, 1 kHz)
Low channel - 500 W + 500 W (per channel at 4 Ω, 100 Hz)
FACTORY
PRESET
This mode is use to load all the factory use preset frequencies into FM 1-FM 20 and AM 1-AM 10. Originally, frequency of FM 1-FM 20 and AM 1-AM10 are set to the minimum frequency.
Procedure:
1. Press the Power button to turn on the system.
2. Press [SEARCH] button and [TUNER/BAND] button simultaneously and hold for 3 seconds, message “FACTORY” appears on the fluorescent indicator tube. The function is changed to TUNER automatically.
DISC
THEFT PREVENTION MODE
This mode is use to load all the factory use preset frequencies into FM 1-FM 20 and AM 1-AM 10. Originally, frequency of FM 1-FM 20 and AM 1-AM10 are set to the minimum frequency.
Procedure:
1. Press the Power button to turn on the system.
2. Press [SEARCH] button and [TUNER/BAND] button simultaneously and hold for 3 seconds, message “FACTORY” appears on the fluorescent indicator tube. The function is changed to TUNER automatically.
This mode let prevent disc to be ejected. When this mode is activated, the disc
will not eject when [EJECT] button is pressed.
The message “LOCKED” will be displayed on the fluorescent indicator tube. This mode only applied when there is disc.
Procedure:
1. Press the Power button to turn on the system.
2. Select CD function.
3. Press [PLAY/PAUSE] button and [EJECT] button simultaneously for 3 seconds. The message “LOCKED” or “UNLOCKED” displayed on the fluorescent indicator tube.
The message “LOCKED” will be displayed on the fluorescent indicator tube. This mode only applied when there is disc.
Procedure:
1. Press the Power button to turn on the system.
2. Select CD function.
3. Press [PLAY/PAUSE] button and [EJECT] button simultaneously for 3 seconds. The message “LOCKED” or “UNLOCKED” displayed on the fluorescent indicator tube.
COMMON TEST MODE
This mode is used to check operations of the Amplifier section.
Procedure:
To enter Common Test Mode
1. Press [USB/USB SELECT] button and [PRESET EQ] button simultaneously and hold for 3 seconds.
2. The upper
segments of fluorescent indicator tube will blink. The function is
changed to TV and the volume is changed to VOLUME MIN.
Check of Amplifier
1. Press
[PRESET EQ] button repeatedly until a message “GEQ MAX” appears on the
fluorescent indicator tube. GEQ increases to its maximum.
2. Press
[PRESET EQ] button repeatedly until a message “GEQ MIN” appears on the
fluorescent indicator tube. GEQ decreases to its minimum.
3. Press [PRESET EQ] button repeatedly until a message “GEQ FLAT” appears on the fluorescent indicator tube. GEQ is set to flat.
4. When the
[MASTER VOLUME] knob is turned clockwise even slightly, the sound volume
increases to its maximum and a message “VOLUME MAX” appears on the
fluorescent indicator tube.
5. When the
[MASTER VOLUME] knob is turned counterclockwise even slightly, the sound
volume decreases to its minimum and a message “VOLUME MIN” appears on
the fluorescent indicator tube.
To release from Common Test mode
1. To release from this mode, press the Power button.
2. The cold reset is enforced at the same time.
PANEL TEST MODE
This mode is
used to check the fluorescent indicator tube, LEDs, keys, [MASTER
VOLUME] jog, model, destination and software version.
Procedure:
1. Press [SEARCH] button and [OPTIONS] button simultaneously and hold 3 seconds.
2. All LEDs and segments in fluorescent indicator tube will light up.
3. When you
want to enter to the software version display mode, press [FLANGER]
button. The model information appears on the fluorescent indicator tube.
Press [FLANGER] button again to view the destination information.
4. During the
destination information display, press [FLANGER] button. Each time
[FLANGER] button is pressed, the fluorescent indicator tube shows the
version of each category software in the following sequence: SC, MTK
(DMB Board firmware version), UI, PF, SYS, CD, CDMA, CDMB, ST, TA, TAS,
TM and return back to model information display.
5. When
[SEARCH] button is pressed while the version numbers are being displayed
except model and destination, the date of the software creation
appears. When [SEARCH] button is pressed again, the display returns to
the software version display.
6. Press [ISOLATOR] button, the key check mode is activated.
7. In the key
check mode, the fluorescent indicator tube displays “K 0 V0”. Each time
a button is pressed, “K” value increases. However, once a button has
been pressed, it is no longer taken into account. “V” value increases
in the manner of 0, 1, 2, 3 ... if [MASTER VOLUME] knob is turned
clockwise, or it decreases in the manner of 0, 9, 8, 7 ... if [MASTER
VOLUME] knob is turned counterclockwise.
8. When
[SOUND FLASH] button is pressed after all LEDs and segments in
fluorescent indicator tube light up, alternate segments in fluorescent
indicator tube and LEDs would light up. If you press [SOUND FLASH]
button again, another half of alternate segments in fluorescent
indicator tube and LEDs would light up. Pressing [SOUND FLASH] button
again would cause all segments in fluorescent indicator tube and LEDs
light OFF. Pressing [SOUND FLASH] button again would cause all segments
in fluorescent indicator tube and all LEDs light up.
9. To release
from this mode, press the [SEARCH] button and [OPTIONS] button in the
same manner as step 1, or disconnect the power cord.
COLD
RESET
The cold reset clears all data including preset data stored in the EEPROM to initial conditions. Execute this mode when returning the set to the customer.
Procedure:
1. Press the Power button to turn on the system.
2. Press the Stop button and the Power button simultaneously for 3 seconds.
3. “COLD RESET” appears on the fluorescent indicator tube. After that, the fluorescent indicator tube becomes blank for a while, and the system is reset.
The cold reset clears all data including preset data stored in the EEPROM to initial conditions. Execute this mode when returning the set to the customer.
Procedure:
1. Press the Power button to turn on the system.
2. Press the Stop button and the Power button simultaneously for 3 seconds.
3. “COLD RESET” appears on the fluorescent indicator tube. After that, the fluorescent indicator tube becomes blank for a while, and the system is reset.
TUNER
STEP CHANGE
The step interval of AM channels can be toggled between 9 kHz and 10 kHz. This mode is not available for Saudi Arabian, European and Russian models.
Procedure:
1. Press the Power button to turn on the system.
2. Press [FUNCTION] button repeatedly to select the “AM”.
3. Press the Power button to turn off the system.
4. Press [ENTER] button and Power button simultaneously. The system turns on automatically. The message “AM 9K STEP” or “AM 10K STEP” appears on the fluorescent indicator tube and thus the channel step is changed.
The step interval of AM channels can be toggled between 9 kHz and 10 kHz. This mode is not available for Saudi Arabian, European and Russian models.
Procedure:
1. Press the Power button to turn on the system.
2. Press [FUNCTION] button repeatedly to select the “AM”.
3. Press the Power button to turn off the system.
4. Press [ENTER] button and Power button simultaneously. The system turns on automatically. The message “AM 9K STEP” or “AM 10K STEP” appears on the fluorescent indicator tube and thus the channel step is changed.
CD
SHIP MODE (WITH MEMORY CLEAR)
This mode moves the optical pick-up to the position durable to vibration and clears all data including preset data stored in the data flash to initial conditions during the next AC-In. Use this mode when returning the set to the customer after repair.
Procedure:
1. Press the Power button to turn on the system.
2. Select CD function and without dics inserted.
3. Press [EJECT] button and the Power button simultaneously for 3 seconds. The system turns off automatically.
4. A message “MECHA LOCK” is displayed on the fluorescent indicator tube and the CD ship mode is set.
This mode moves the optical pick-up to the position durable to vibration and clears all data including preset data stored in the data flash to initial conditions during the next AC-In. Use this mode when returning the set to the customer after repair.
Procedure:
1. Press the Power button to turn on the system.
2. Select CD function and without dics inserted.
3. Press [EJECT] button and the Power button simultaneously for 3 seconds. The system turns off automatically.
4. A message “MECHA LOCK” is displayed on the fluorescent indicator tube and the CD ship mode is set.
CD Mechanism - Exploded