HOW TO ADJUST Va and Vs VOLTAGES TO LG PLASMA TVs
LG 32”XGA_50”_42”_60” Plasma Televisions
Display Panel Voltage (Va & Vs) adjustment procedure
50” POWER PCB Ass’y Voltage Adjustment (Va, Vs voltage
Adjustment). 50PG6000, 50PG6010
Va Adjustment.
* After receiving 100% Full White Pattern, HEAT RUN.
* Connect + terminal of D. M.M. to Va pin of P811, connect -terminal to GND pin of P811.
* After turning VR901,voltage of D.M.M adjustment as same as Va voltage which on label of panel right/top (deviation; ±0.5V)
* After receiving 100% Full White Pattern, HEAT RUN.
* Connect + terminal of D. M.M. to Va pin of P811, connect -terminal to GND pin of P811.
* After turning VR901,voltage of D.M.M adjustment as same as Va voltage which on label of panel right/top (deviation; ±0.5V)
Vs Adjustment
* Connect + terminal of D. M..M. to Vs pin of P811, connect -terminal to GND
pin of P811.
* After turning VR951, voltage of D.M.M adjustment as same as Vs voltage which on label of panel right/top(deviation ; ±0.5V)
* After turning VR951, voltage of D.M.M adjustment as same as Vs voltage which on label of panel right/top(deviation ; ±0.5V)
42” POWER PCB Ass’y Voltage Adjustment (Va, Vs voltage
Adjustment) 42PG6000, 42PG6010
Va Adjustment.
> After receiving 100% Full White Pattern, HEAT RUN.
> Connect + terminal of D. M..M. to Va pin of P811, connect -terminal to GND pin of P811.
> After turning VR901,voltage of D.M.M adjustment as same as Va voltage which on label of panel right/top (deviation; ±0.5V)
> Connect + terminal of D. M..M. to Va pin of P811, connect -terminal to GND pin of P811.
> After turning VR901,voltage of D.M.M adjustment as same as Va voltage which on label of panel right/top (deviation; ±0.5V)
Vs Adjustment
> Connect + terminal of D. M..M. to Vs pin of P811, connect -terminal to GND pin of P811.
> After turning VR951, voltage of D.M.M adjustment as same as Vs voltage which on label of panel right/top(deviation ; ±0.5V)
> Connect + terminal of D. M..M. to Vs pin of P811, connect -terminal to GND pin of P811.
> After turning VR951, voltage of D.M.M adjustment as same as Vs voltage which on label of panel right/top(deviation ; ±0.5V)
60”(FHD), 50”(FHD) POWER PCB Ass’y
Voltage Adjustment (Va, Vs voltage Adjustment). 50PG7000, 60PG7000, 50PG4000
Va Adjustment.
* After receiving 100% Full White Pattern, HEAT RUN.
* Connect + terminal of D. M..M. to Va pin of P11, connect -terminal to GND pin of P11.
* After turning VR901,voltage of D.M.M adjustment as same as Va voltage which on label of panel right/top (deviation; ±0.5V)
* After receiving 100% Full White Pattern, HEAT RUN.
* Connect + terminal of D. M..M. to Va pin of P11, connect -terminal to GND pin of P11.
* After turning VR901,voltage of D.M.M adjustment as same as Va voltage which on label of panel right/top (deviation; ±0.5V)
Vs Adjustment.
* Connect + terminal of D. M..M. to Vs pin of P11, connect -terminal to GND pin of P11.
* After turning VR951, voltage of D.M.M adjustment as same as Vs voltage which on label of panel right/top(deviation ; ±0.5V)
* Connect + terminal of D. M..M. to Vs pin of P11, connect -terminal to GND pin of P11.
* After turning VR951, voltage of D.M.M adjustment as same as Vs voltage which on label of panel right/top(deviation ; ±0.5V)
32”(XGA) POWER PCB Ass’y Voltage
Adjustment (Va,
Vs voltage Adjustment). 32PG6000, 32PG6010
Va Adjustment.
1. After receiving 100% Full White Pattern, HEAT RUN.
2. Connect + terminal of D. M.M. to Va pin of P811, connect -terminal to GND pin of P811.
3. After turning VR901,voltage of D.M.M adjustment as same as Va voltage which on label of panel right/top (deviation; ±0.5V)
2. Connect + terminal of D. M.M. to Va pin of P811, connect -terminal to GND pin of P811.
3. After turning VR901,voltage of D.M.M adjustment as same as Va voltage which on label of panel right/top (deviation; ±0.5V)
Vs Adjustment
1. Connect + terminal of D. M..M. to Vs pin of P811, connect
-terminal to GND pin of P811.
2. After turning VR951, voltage of D.M.M adjustment as same as Vs voltage which on label of panel right/top(deviation ; ±0.5V)
2. After turning VR951, voltage of D.M.M adjustment as same as Vs voltage which on label of panel right/top(deviation ; ±0.5V)
The module keeping condition
* The normal temperature condition (more
than 15°C) > Immediately the line supply.
* The module keeping condition: 0°C > The module must be kept for more than 2 hours at the normal temperature.
* The module keeping condition: -20°C > The module must be kept for more than 3 hours at the normal temperature.
* The case of Gu-mi factory at the winter season. > The module must be kept for more than 5 minutes at the heating zone (40°C~45°C)
* The module keeping condition: 0°C > The module must be kept for more than 2 hours at the normal temperature.
* The module keeping condition: -20°C > The module must be kept for more than 3 hours at the normal temperature.
* The case of Gu-mi factory at the winter season. > The module must be kept for more than 5 minutes at the heating zone (40°C~45°C)
Because this is not a hot chassis, it is not necessary to use an
isolation transformer. However, the use of isolation transformer will help
protect test instrument.
> Adjustment must be done in the correct order.
> The adjustment must be performed in the circumstance of 25±5°C of temperature and 65±10% of relative humidity if there is no specific designation.
> The input voltage of the receiver must keep 100~240V, 50/60Hz.
> The receiver must be operated for about 5 minutes prior to the adjustment.
After RGB Full White in HEAT-RUN Mode, the receiver must be operated prior to the adjustment.
> Adjustment must be done in the correct order.
> The adjustment must be performed in the circumstance of 25±5°C of temperature and 65±10% of relative humidity if there is no specific designation.
> The input voltage of the receiver must keep 100~240V, 50/60Hz.
> The receiver must be operated for about 5 minutes prior to the adjustment.
After RGB Full White in HEAT-RUN Mode, the receiver must be operated prior to the adjustment.
To Enter into HEAT-RUN MODE
* Press the POWER ON KEY on R/C for adjustment.
* Press the POWER ON KEY on R/C for adjustment.
* Press the ADJ KEY on R/C and enter EZ ADJUST Select “3. Test
Pattern” by using D /E (CH +/-) and press ENTER(V ) Select “White” by using F
/G (VOL +/-) and press ENTER(V )
> Set is activated HEAT run without signal generator in this mode.
> Single color pattern (RED / BLUE / GREEN) of HEAT RUN MODE uses to check panel.
Caution: If you turn on a still screen more than 20 minutes (Especially digital pattern, cross hatch pattern), an after image may be occur in the black level part of the screen.
> Set is activated HEAT run without signal generator in this mode.
> Single color pattern (RED / BLUE / GREEN) of HEAT RUN MODE uses to check panel.
Caution: If you turn on a still screen more than 20 minutes (Especially digital pattern, cross hatch pattern), an after image may be occur in the black level part of the screen.