PANASONIC - TY-TP42P10S _ TY-TP50P10S _25-POINT CALIBRATION
25 POINT ADJUSTMENTS
Prepare setting for adjusting PC
- Create folder and copy files listed below for Excel data processing.
- Create a folder directly onto the C Drive. C:/25PDATA
- Copy the files and create the data folder listed below into the "25PDATA" folder.
- 25P Adjustment Data Procssing.xls
- Grid.exe
- grid.ini
- import.prm
- data folder (C:\25DATA\data)
- Adjustment processing result will be saved in the data folder automatically ("S/N" xls).’
Prepare setting of Excel
- Start up the Visual Basic Editor by selecting "Tool" - "Macro" -> "Visual Basic Editor".
- Select "Reference Setting" from "Tool".
- Put a check mark on "SOLVER" in available references.
- If .SOLVER.xla. doesn.t exist or does not show in references, press .reference. to select .SOLVER.xla..SOLVER.xla. should be in C\Program Files\Microsoft Office\Library\Solver.
EXPLANATION OF 25-POINT CALIBRATION
To start performing 25-point
Calibration
- Start up .LtabMon S. (Make sure the Touch Driver is not running.)
- Press 'Sampling' Detailed sampling data box will appear.
- Start up 'Grid.exe'
- While touching the cross point in the top left corner with the touch pen, press .Capture (Enter Key).
- Move to right one section and press 'Capture (Enter key)'. Repeat the same procedure to get calibration data from 5 points.
- Move to far left corner in the second row, repeat the same procedure from left to right to get calibration data. Collect data from all 25 points.
- When you finish with the last point, press .Save.
- Right-click to close 'Grid'
- RES.dat will be saved in 25PDATA folder in C drive.
Excel data processing (Make sure the
setting has been prepared before hand.)
- Start up .25P Adjustment Data Procssing.xls. (Macro).
- Select a number for adjusting model.
- 1:50 inch TY-TP50P10S
- 2:42 inch TY-TP42P10S
- 3:58 inch TY-TP58P10S
- 4:65 inch TY-TP65P10S
- Process the aquired data. Press .RES - RES0. Press .OK. According to the message dialog box.
- Perform the data validation and defrag. Press 'Validation & Initialization & Defrag'
- Press 'DATA - Export' to save result of the calibration.
- The data will be saved as 'importf.prm' in 25PDATA folder.
- Press 'Exit' to quit.
- Enter products serial number when asked for S/N.
- S/N.xls. will be saved in 25PDATA folder.
- Import the aquired data.
- Press 'Parameter' in LTabMonS.
- Press 'Load File' to open 'importf.prm' file saved in 25PDATA folder.
- The result will be imported and reflect to each parameter.
- Press 'Write to ROM' to write.
- Exit 'LtabMon' to finish.
PRECISE CALIBRATION
- Make sure the LtabMonS is not running. Start up the 'Touch Driver'
- Press 'precise calibration' from the driver.s setup panel.
- “precise calibration” dialog box will appear.
- Press”OK”.
- Touch the “X” marker in the top right corner (shown in yellow) with the touch pen to stop.
- When the driver capture XY coordinates, the yellow “X” marker moves one to right.
- Capture XY coordinate for each "X" marker shown in yellow.
- Get data from all 25 points.
- When you finish collecting data from all points, the calibration result will be asked.
- Then press ‘OK’ to exit.
CHECK FOR CALIBRATING RESULT [TEST]
- Exit the driver.s setup panel, and touch any marker to test.
- Point positions should not be too far off. It should be whithin 5 mm.
- In order to test, set the setting to 0 (zero) in the “Allowance for point position differences” in the setup panel of Touch Driver.