REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Saturday 9 March 2019

SAMSUNG UN40D6400UF - UN46D6400UF - UN55D6400UF TROUBLE SHOOTING SOFTWARE UPDATE AND SERVICE MODE

SAMSUNG UN40D6400UF - UN46D6400UF - UN55D6400UF TROUBLE SHOOTING SOFTWARE UPDATE AND SERVICE MODE


SAMSUNG UN40D6400UF - UN46D6400UF - UN55D6400UF 

3D EDGE LIT LED TV


TROUBLE SHOOTING SOFTWARE UPDATE AND SERVICE MODE 


Troubleshooting
1. Check the various cable connections first.
# Check to see if there is a burnt or damaged cable.
# Check to see if there is a disconnected or loose cable connection.
# Check to see if the cables are connected according to the connection diagram.
2. Check the power input to the Main Board.
3. How to distinguish if the problem is caused by Main board or T-Con.
a. No Video : If the problem is No Video but BLU is on and Indication LED is blinking repeatedly and faster than nomal booting, replace the T-Con board.
b. Distorted Picture : Check the inner patterns.
How to check inner pattern
1. Factory mode(Mute > 1 > 8 >  2 >  Power on when TV is in ‘Stand-by mode’)
2. Move to SVC menu.
3. Move to Test Pattern.
4. Check inner patterns.
(This model only support GenoaS, GenoaS FRC POST, HDMI)
No Power
Symptom
The LEDs on The front panel do not work when connecting The power cord.
The SMPS relay does not work when connecting The power cord.
The units appears to be dead.
Check points
The IP relay or the LEDs on the front panel does not work when connecting the power cord if the cables are
improperly connected or the Main Board or SMPS is not functioning. In this case, check the following:
Check the internal cable connection status inside the unit.
Check the fuses of each part.
Check the output voltage of SMPS.
Replace the Main Board.
No Video (Analog PC signal)
Symptom
Audio is normal but no picture is displayed on the screen.
Check points
Check the PC source
Check the Genoa-P
This may happen when the LVDS cable connecting the Main Board and the Panel is disconnected.
No Video (HDMI - Digital Signal)
Symptom
Audio is normal but no picture is displayed on the screen.
Check points
Check the HDMI source
Check the Valencia
This may happen when the LVDS cable connecting the Main Board and the Panel is disconnected.
No Video (Tuner_CVBS)
Symptom
Audio is normal but no picture is displayed on the screen.
Check points
Check the Tuner CVBS source
Check the Genoa-P
This may happen when the LVDS cable connecting the Main Board and the Panel is disconnected.
No Video (Tuner DTV)
Symptom
Audio is normal but no picture is displayed on the screen.
Check points
Check the DTV source.
Check the Tuner, Check the Valencia.
This may happen when the LVDS cable connecting the Main Board and the Panel is disconnected.
No Video (Video CVBS 1, 2)
Symptom
Audio is normal but no picture is displayed on the screen.
Check points
Check the Video CVBS source.
Check the Tuner, Check the Valencia.
This may happen when the LVDS cable connecting the Main Board and the Panel is disconnected.
No Video (Component)
Symptom
Audio is normal but no picture is displayed on the screen.
Check points
Check the Component source
Check the Valencia
This may happen when the LVDS cable connecting the Main Board and the Panel is disconnected.
No Sound (1.Speaker 2.Monitor_out, 3.Optical)
Symptom
Video is normal but there is no sound.
Check points
When the speaker connectors are disconnected or damaged.
When the sound processing part of the Main Board is not functioning.
Speaker defect..
Factory Mode Adjustments
Entering Factory Mode
To enter ‘Service Mode’ Press the remote -control keys in this sequence :
 If you do not have Factory remote - control
Power OFF > MUTE > 1 > 8 > 2 > Power On
If you have Factory remote-control
INFO > Factory
If you don’t have Factory remote control, can’t control some menus. (Expert, Advanced menu)
AV Color Calibration Method
1) Apply the NTSC Lattice (N0. 3) pattern signal to the AV IN 1 port
2) Press the Source key to switch to "AV1" mode
3) Enter Service mode
4) Select the "ADC/WB" and "ADB" menu
5) Select the "AV Calibration" menu.
6) In "AV Calibration Off" status, press the " > " key to perform Calibration.
7) When Calibration is complete, it returns to the high-level menu.
8) You can see the change of the "AV Calibration" status from Failure to Success.
Component Color Calibration Method
1) Apply the 720p Lattice (N0. 6) pattern signal to the Component IN 1 port
2) Press the Source key to switch to "component" mode
3) Enter Service mode
4) Select the "ADC/WB" and "ADB" menu
5) Select the "Comp Calibration" menu.
6) In "Comp Calibration Off" status, press the " > " key to perform Calibration.
7) When Calibration is complete, it returns to the high-level menu.
8) You can see the change of the "Comp Calibration" status from Failure to Success.
PC Color Calibration Method
1) Apply the VESA XGA Lattice (N0. 21) pattern signal to the PC IN port
2) Press the Source key to switch to "PC" mode
3) Enter Service mode
4) Select the "ADC/WB" and "ADB" menu
5) Select the "PC Calibration" menu.
6) In "PC Calibration Off" status, press the " > " key to perform Calibration.
7) When Calibration is complete, it returns to the high-level menu.
8) You can see the change of the "PC Calibration" status from Failure to Success.
HDMI Color Calibration Method
1) Apply the 720p Lattice (N0. 6) pattern signal to the HDMI1/DVI IN port
2) Press the Source key to switch to "HDMI1" mode
3) Enter Service mode
4) Select the "ADC/WB" and "ADB" menu
5) Select the "HDMI Calibration" menu.
6) In "HDMI Calibration Off" status, press the " > " key to perform Calibration.
7) When Calibration is complete, it returns to the high-level menu.
8) You can see the change of the "HDMI Calibration" status from Failure to Success.
Software Upgrade
Software Upgrade can be performed by network connection or downloading the latest firmware from samsung to a USB memory device.
By USB
Insert a USB drive containing the firmware upgrade file, downloaded from “samsung web” into the TV. Please be careful not to disconnect the power or remove the USB drive until upgrades are complete. The TV will be turned off and on automatically after completing the firmware upgrade. When software is upgraded, video and audio settings you have made will return to their default settings. We advise you to to write down your settings so that you can easily reset them after the upgrade.
By Online
Upgrades the software using the Internet.
# First, configure your network. For detailed procedures on using the Network Setting, refer to the ‘Setting the Network’ instructions.
# If The internet connection doesn’t operate properly, connection can be broken, please retry downloading.
If the problem still happens, download by USB and upgrade.
Alternative Software (Backup)
If there is an issue with the new firmware and it is affecting operation, you can change the software to the previous version.
# If Software was changed, existing Software is displayed.
# You can change current Software to Alternative Software by ‘Alternative Software’.
RS-232C
To RS232C Control
Port : COM#(Serial)
Bit rate : 115200
Data Bit : 8 bit
Parity : None
Stop Bits : 1
Flow Control : None
Pin configuration  of RS232C

Pin#
Name
Full Name
1
CD
Carrier Detect
2
RxD
Received Data
3
TxD
Transmitted Data
4
DTR
Data Terminal Ready
5
GND
Signal Ground
6
DSR
Data Set Ready
7
RTS
Request To Send
8
CTS
Clear To Send
9
RI
Ring Indicator