REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Friday, 15 March 2019

SONY PFM-500 - PFM-510 - PLASMA DISPLAY - ERROR CODES AND DETAILS

SONY

PFM-500 - PFM-510 -  PLASMA DISPLAY - ERROR CODES  AND  DETAILS



ERROR CODES


CLICK ON THE TABLE TO MAGNIFY
SERVICE CODES DETAILS _ Self Diagnosis Function

The PFM-500A3W/510A2W has the self diagnosis function using A/D converter to detect the power supply analog voltages, 8 channels of temperature sensor, fan operations, power unit temperature, DC voltage status, and to check the EEPROM and the watch register. When any

abnormality occurs or defect is detected, the Error Code appears on the service code indicator of the power supply block, the standby indicator on the control panel flashes and the detected data is displayed on the service menu [STATUS/TEST] block. If the abnormal status exceeds
the allowable limit, the PFM-500A3W/510A2W is forced to shut down.

Increase and decrease of the panel DC voltage Vs is detected.

(Name of this function on the service menu : POWER SUPPLY - PDP VS)

PFM-510A2W

The normal operating range is +160 V +24 V/_22 V.

Warning of increase of the voltage Vs when 184 V or more : Service code [11]

Warning of decrease of the voltage Vs when 138 V or less : Service code [12]

PFM-500A3W

The normal operating range is +175 V +26 V/_23 V.

Warning of increase of the voltage Vs when 201 V or more : Service code [11]


Warning of decrease of the voltage Vs when 152 V or less : Service code [12]

Increase and decrease of the panel DC voltage Va is detected.

(Name of this function on the service menu : POWER SUPPLY - PDP VA)

The normal operating range is +60 V +15 V/_14 V.

Warning of increase of the voltage Va when 75 V or more : Service code [21]


Warning of decrease of the voltage Va when 46 V or less : Service code [22]

Increase of temperature at the side of the power block in the top of the panel is detected and shut down of the machine.

TEMPERATURE - P/S BLOCK SIDE)

The normal operating range is up to 57 °C.

Warning of high temperature when 58 °C or higher : Service code [31]


Shut down at the temperature of 68 °C or higher : Service code [39]

Increase of temperature at the center in the top of the panel is detected and shut down of the machine.

TEMPERATURE - CENTER)

The normal operating range is up to 55 °C.

Warning of high temperature when 56 °C or higher : Service code [A1]


Shut down at the temperature of 66 °C or higher : Service code [A9]

Increase of temperature at the side of the input connector block in the top of the panel is detected and shut down of the machine.

TEMPERATURE - I/O BLOCK SIDE)

The normal operating range is up to 53 °C.

Warning of high temperature when 54 °C or higher : Service code [41]


Shut down at the temperature of 64 °C or higher : Service code [49]

Detection of outside environment temperature.

TEMPERATURE - AMBIENT TEMP)

Occurrence of abnormality and fault is judged solely from the internal temperature of the PFM-500A3W/510A2W. Measurement of the ambient temperature aims mainly at the confirmation of the operating environment. Therefore, there is no chance to indicate this warning message.


Warning of high temperature at 60 °C or higher : Service code [F1]

Detection of fan stop and that of drive circuit failure.  Three fans at the top of the panel and two fans for power supply.

BLOCK SIDE, CENTER, P/S BLOCK SIDE, No. 1, No. 2)

Status of the respective fans are displayed as OK or NG on the service menu STATUS.

Fan of the power supply block at the top of the rear of the machine : Service code [55]

Fan in the center of the top on the rear of the machine : Service code [54]

Fan on the input terminal at the top on the rear of the machine : Service code [53]

Two fans of the power supply block : Service code [52] or [51]

Detection of fan drive circuit failure

(Name of this function on the service menu : FAN - DRIVE CIRCUIT)


The warning when the fan drive data is 6 V or more and the actual drive voltage is 2 V or less : Service code [58]

Detection of temperature rise in the power supply block.

TEMPERATURE - P/S INTERNAL)

Warning of high temperature when temperature of the heat sink for main converter inside the power supply unit exceeds the allowable limit : Service code [61]

Shut down when the 5 V for internal digital circuit has abnormality.

POWER SUPPLY - DIGITAL 5V)

The voltage that is input to pin-62 of the system controller (IC252) is detected.


Shut down when there is no input voltage : Service code [79]

Detection of failure of the EEPROM

Warning when communication with EEPROM cannot be performed normally.

EEPROM ID code error: Service code [81]

EEPROM data write error: Service code [82]

EEPROM data read error: Service code [83]


EEPROM failure: Service code [85]

Detection of abnormality in communication with scan converter.

(Name of this function on the service menu : Nil)

Warning when communication with scan converter cannot be performed normally.


EEPROM ID code error : Service code [91]

Detection of failure in the ON/OFF control of power supply.

(Name of this function on the service menu : Nil)


When the digital 5 V power does not decrease even in the STBY state, the machine enters the POWR ON state automatically : Service code [98]

Detection of decreased backup power supply voltage for watch and detection of abnormality in oscillator.

(Name of this function on the service menu : Nil)

Normal/abnormal is detected from the register value inside the watch IC.

Initialization of time due to abnormal register value : Service code [B1]

Warning of low voltage of backup power supply : Service code [B2]


Warning that crystal oscillator for watch has stopped : Service code [B3]

Detection of PDP failure using the combination of the voltage detection and shut down of the machine.

(Name of this function on the service menu : Nil)

PDP is suspected to be defective when DIGITAL 5 V is normal among the voltages (VS, VA, DIGITAL 5V) required to drive PDP while both VS and VA are not inputted.  When all the following conditions are satisfied, the machine enters once to the STANDBY mode then turn the main power back on again.

1) DC 180 V power is 40 V or less.

2) DC 70 V power is 20 V or less.

3) DIGITAL 5 V is normal.


The above-described operation is repeated three times.  If the above three conditions are still satisfied, the PDP is judged to be faulty and the main power is shut down.  Service code [99]