REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Showing posts with label SYLVANIA. Show all posts
Showing posts with label SYLVANIA. Show all posts

Friday, 24 April 2020

PHILIPS, MAGNAVOX, SYLVANIA AND EMERSON 40 INCH LCD TVS HOW TO ENTER THE SERVICE MODE, SERVICE MODE ADJUSTMENTS - TROUBLESHOOTING - SMPS SCHEMATIC

Electrical adjustments

Test Equipment Required
NTSC Pattern Generator (Color Bar W/White Window, Red Color, Dot Pattern, Gray Scale, Monoscope, Multi-Burst)
Remote control unit
Color Analyzer
How to set up the service mode
Turn the power on.
2. Press [MENU] button to display Setup menu.
3. Select “Features”.
4. Select “Current Software Info”.
5. Press [0], [4], [2], [5], [7], [4] and [Info] buttons on the remote control unit in this order. The following screen appears.
Purity Check Mode
This mode cycles through full-screen displays of red, green, blue, and white to check for non-active pixels.
1. Enter the Service mode.
2. Each time pressing [7] button on the remote control unit, the display changes.
3. To cancel or to exit from the Purity Check Mode, press [PREV CH] button.

Applicable to:
40”
40”
40”
40”
40”
40”
40MF430B/F7
40MF430B/F7
LC407SS1
LC407SS1
LC407SS1
LC407EM1
MAGNAVOX
MAGNAVOX
SYLVANIA
SYLVANIA
SYLVANIA
EMERSON
(Serial No. : DS1A)
(Serial No. : DS2A)
(Serial No. : DS1A)
(Serial No. : DS2A)
(Serial No. : DS3A)

The White Balance Adjustment should be performed when replacing the LCD Panel or Digital Main CBA.
Symptom of Maladjustment: White becomes bluish or reddish.
Operate the unit for more than 20 minutes.
2. Input the White Raster (70%=70IRE, 40%=40IRE).
3. Set the color analyzer to the CHROMA mode and bring the optical receptor to the center on the LCD-Panel surface after zero point calibration as shown above.
Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
4. Enter the Service mode. Press [VOLUME DOWN] button on the remote control unit and select “C/D” mode.
5. [CUTOFF]
Press [1] button to select “COR” for Red Cutoff adjustment. Press [3] button to select “COB” for Blue Cutoff adjustment.
[DRIVE]
Press [4] button to select “DR” for Red Drive adjustment. Press [6] button to select “DB” for Blue Drive adjustment.
6. In each color mode, press [CHANNEL UP/DOWN] buttons to adjust the values of color.
7. Adjust Cutoff and Drive so that the color temperature becomes 12000°K (x= 0.272 / y= 0.278 ±0.005).
8. To cancel or to exit from the White Balance Adjustment, press [PREV CH] button.
How to initialize the LCD TV
The purpose of initialization is to place the set in a new out of box condition. The customer will be prompted to select a language and program channels after the set has been initialized.
To put the program back at the factory-default, initialize the LCD TV using the following procedure.
1. Turn the power on.
2. Enter the service mode.
- To cancel the service mode, press [POWER] button on the remote control unit.
3. Press [INFO] button on the remote control unit to initialize the LCD television.
4. "INITIALIZED" will appear in the upper right of the screen. "INITIALIZED" color will change to green from red when initializing is completed.
Firmware renewal
Equipment Required
a. USB storage device
b. Remote Control Unit
[There are two states (the User Upgrade and the Factory Upgrade) in firmware update.]
User Upgrade > Upgrade the firmware only.  The setting values are not initialized.
Factory upgrade > Upgrade the firmware and initialize the setting values.
The identification of User Upgrade and Factory Upgrade are done by the filename.
1. Turn the power off and unplug the AC Cord.
2. Insert the USB storage device to the USB port as shown below.
The USB port “SERVICE TERMINAL” will be blocked by a cross shaped piece of plastic. Cutoff both end of the plastic connected to the PCB Holder as illustrated below.
3. Plug the AC cord in the wall outlet and turn the power on.
4. The update will start and the following will appear on the screen.
Note: If the screen isn’t displayed, repeat from step 1
5. When the firmware update is completed, the following will appear on the screen.
Remove the USB storage device from the USB port.
Turn the power off and turn the power on again.
[When the Factory Upgrade is used, after restarting TV, shift to initial screen menu in service mode. "INITIALIZED" will appear on the upper right of the screen. "INITIALIZED" color will change to green from red when initializing is completed.]
Troubleshooting table
SMPS [Power supply schematic]
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.  If Main Fuse (F1601) is blown , check to see that all components in the power supply circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
Power Supply 1 Schematic Diagram
Power Supply 2 Schematic Diagram
Power Supply 3 Schematic Diagram

Thursday, 11 April 2019

SYLVANIA LC220SS2 - EMERSON LC220EM2 - MAGNAVOX 22ME601B - SERVICE MODE – VCOM ADJUSTMENT – INITIALIZATION – FIRMWARE UPDATE

SYLVANIA LC220SS2 - EMERSON LC220EM2 - MAGNAVOX 22ME601B - Service mode – Vcom adjustment – Initialization – firmware update

Service mode:
1. Turn the power on.
2. Press [MENU] button to display Setup menu.
3. Select “Features”.
4. Select “Current Software Info”.
5. Press [0], [4], [2], [5], [7], [4] and [INFO] buttons on the remote control unit in this order. The following screen appears.
1. Purity Check Mode
This mode cycles through full-screen displays of red, green, blue, and white to check for non-active pixels.
1. Enter the Service mode.
2. Each time the [7] button on the remote control unit is pressed , the display changes.
3. To cancel or to exit from the Purity Check Mode, press [CH RETURN] or [PREV CH] button.
VCOM Adjustment
1. Operate the unit for more than 60 minutes.
2. Set the color analyzer at the zero point calibration and bring the optical receptor pointing at the center of the LCD-Panel.
Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
3. Enter the Service mode.
4. Press [3] button on the remote control unit.
5. Press [CHANNEL UP/DOWN] buttons on the remote control unit so that the color analyzer value becomes minimum.
6. To cancel or to exit from the VCOM Adjustment, press [CH RETURN] or [PREV CH] button.
The White Balance Adjustment should be performed when replacing the LCD Panel
or Digital Main CBA.
3. White Balance Adjustment
Purpose: To mix red and blue beams correctly for pure white.
Symptom of Misadjustment: White becomes bluish or reddish.
ITEM SPECIFICATION
Color temperature x= 0.272 +/-0.002
y= 0.278 +/- 0.002
Input Signal Internal pattern
(40/70% raster)
Measurement point Screen center
M. EQ. CA-310 (KONICA MINOLTA
Luminance meter) or
measuring instrument as
good as CA-310.
Aging time 60min.
(Retail MODE/100IRE Raster
HDMI 1080i@60)
MODE setting of TV Shipment setting/ Retail MODE
Ambient
temperature 25 degreeC ± 5 degreeC
1. Operate the unit for more than 60 minutes.
2. Enter the Service mode.
3. Press [VOLUME DOWN] button three times on the remote control unit to select “Drive setting” mode. “Drive” appears on the screen.
4. Set the color analyzer at the CHROMA mode and zero point calibration. Bring the optical receptor pointing at the center of the LCD-Panel.
Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
5. Press [3] button to select the “HDB” for High Drive Blue adjustment. (“HDB” appears on the screen.)
6. Press [MENU] button. The internal Raster signal appears on the screen. (“Internal (Single)” appears on the upper right of the screen as shown below.)
7. Press [CHANNEL UP/DOWN] buttons to adjust the color temperature becomes 12000 degree K (x= 0.272 / y= 0.278 ±0.002).
8. Press [1] button to select the “HDR” for High Drive Red adjustment (“HDR” appears on the screen.) and press [CHANNEL UP/DOWN] buttons to adjust the color temperature.
9. If necessary, adjust the “HDB” or “HDR” again.
10. Press [6] button to select the “LDB” for Low Drive Blue adjustment (“LDB” appears on the screen.) and press [CHANNEL UP/DOWN] buttons to adjust the color temperature.
11. Press [4] button to select the “LDR” for Low Drive Red adjustment (“LDR” appears on the screen.) and press [CHANNEL UP/DOWN] buttons to adjust the color temperature.
12. If necessary, adjust the “LDB” or “LDR” again.
13. Press [VOLUME DOWN] button to shift to the “Debugging Message” mode.
If there is no message under “[WB]” section, this adjustment completes. If “Drive settings are NG. Retry.” is displayed, repeat above steps from 5. to 12. Then check
“Debugging Message” again. If “Drive settings are NG. Retry.” is displayed, replace the LCD Panel or Digital Main CBA.
14. To cancel or to exit from the White Balance Adjustment, press [CH RETURN] or [PREV CH] button.
INITIALIZE THE LCD TV
The purpose of initialization is to place the set in a new out of box condition. The customer will be prompted to select a language and program channels after the set has been initialized.
To put the program back at the factory-default, initialize the LCD TV using the following procedure.
1. Turn the power on.
2. Enter the service mode.
- To cancel the service mode, press [POWER] button on the remote control unit.
3. Press [FREEZE] button on the remote control unit to initialize the LCD television.
4. "INITIALIZED" will appear in the upper right of the screen. "INITIALIZED" color will change to green from red when initializing is completed.
Firmware Update Procedure
1. Turn the power off and unplug the AC Cord.
2. Insert the USB storage device to the USB port
3. Plug the AC cord in the wall outlet and turn the power on.
4. The update will start and appear on the screen.
5. When the firmware update is completed, Remove the USB storage device from the USB port. Turn the power off and turn the power on again will appear on the screen.
Note:
When the Factory Upgrade is used, after restarting TV, shift to initial screen menu in service mode. "INITIALIZED" will appear on the upper right of the screen. "INITIALIZED" color will change to green from red when initializing is completed.

Wednesday, 10 April 2019

SYLVANIA, EMERSON AND MAGNAVOX 19 INCH LCD TV – HOW TO ENTER SERVICE MODE, ADJUSTMENTS, INITIALIZATION AND SCHEMATICS AND MORE

Sylvania, Emerson and Magnavox 19 inch LCD TV – How to enter service mode, adjustments, initialization and more

Applicable to: Sylvania LC195SLX, Emerson LC195EMX, Magnavox 22MF339B/F7 and many more models of these brands 19 inch LCD TVs. HOW TO INITIALIZE THE LCD TV
The purpose of initialization is to place the set in a new out of box condition. The customer will be prompted to select a language and program channels after the set has been initialized.
To put the program back at the factory-default, initialize the LCD TV using the following procedure.
1. Turn the power on.
2. To enter the service mode, press the service button on the service remote control unit.
- To cancel the service mode, press [POWER] button on the service remote control unit.
3. Press [INFO] button on the service remote control unit to initialize the LCD television.
4. "INITIALIZED" will appear in the upper right of the screen. "INITIALIZED" color will change to green from red when initializing is complete.
FIRMWARE RENEWAL MODE
Equipment Required
a. USB memory
b. Remote Control Unit
Firmware Update Procedure
Note: There are two states (the User Upgrade and the Factory Upgrade) in firmware update.
The identification of User Upgrade and Factory
Upgrade are done by the filename.
1. Turn the power off and unplug the AC Cord.
2. Insert the USB memory to the USB port.
3. Plug the AC cord in the wall outlet and turn the power on.
4. The update will start and the following will appear on the screen.
“Software upgrade in progress. Please wait.
Do not remove the USB device or turn the TV off while upgrade is in progress”
If the above screen isn’t displayed, repeat from step 1
5. When the firmware update is completed, the screen will be displayed.
Unplug the AC cord and kindly remove the USB memory from the USB port. Plug the AC cord in the wall outlet again and turn the power on.
Note:
When the Factory Upgrade is used, after restarting TV, shift to initial screen menu in service  mode. "INITIALIZED" will appear on the upper right of the screen. "INITIALIZED" color will change to green from red when initializing is complete.
Service mode
Electrical adjustments are required after replacing circuit components and certain mechanical parts. It is important to perform these adjustments only after all repairs and replacements have been completed.  Also, do not attempt these adjustments unless the proper equipment is available.
Test Equipment Required
1. NTSC Pattern Generator (Color Bar W/White Window, Red Color, Dot Pattern, Gray Scale, Monoscope, Multi-Burst)
2. Remote control unit
3. Color Analyzer.
How to make the Service remote control unit:
[LC195SLX, LC195EMX]
Cut “A” portion of the attached remote control unit as shown in Fig.
[22MF339B/F7, 19MF339B/F7]
Cut “A” portion of the attached remote control unit as shown in Fig.
[LC225SSX, LC195SSX]
Cut “A” portion of the attached remote control unit as shown in Fig.
How to set up the service mode:
How to enter the Service mode:
1. Use the service remote control unit.
2. Turn the power on.
3. Press the service button on the service remote control unit. The service mode screen appears.
LC195SLX, LC195EMX, LC195SSX, 19MF339B/F7 – SMPS section schematic
22MF339B/F7, LC225SSX – Back-light inverter schematic
22MF339B/F7, LC225SSX – SMPS section schematic
Purity Check Mode
This mode cycles through full-screen displays of red, green, blue, and white to check for non-active pixels.
1. Enter the Service mode.
2. Each time pressing [7] button on the service remote control unit, the display changes as follows.
VCOM Adjustment

1. Operate the unit for more than 20 minutes.
2. Set the color analyzer and bring the optical receptor to the center on the LCD-Panel surface after zero point calibration.
Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
3. Enter the Service mode.
4. Press [3] button on the service remote control unit.
5. Press [CHANNEL UP/DOWN] buttons on the service remote control unit so that the color analyzer value becomes minimum.
The white balance adjustment should be performed when replacing the LCD Panel or Digital CBA.
3. White Balance Adjustment
Purpose: To mix red, green and blue beams correctly for pure white.
Symptom of Maladjustment: White becomes bluish or reddish.
Operate the unit for more than 20 minutes.
2. Input the White Raster(70%=70IRE, 40%=40IRE).
3. Set the color analyzer to the CHROMA mode and bring the optical receptor to the center on the LCD-Panel surface after zero point calibration.
Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
4. Enter the Service mode. Press [VOLUME DOWN] button on the service remote control unit and select “C/D” mode.
5. [CUTOFF]
Press [1] button to select “COR” for Red Cutoff adjustment. Press [3] button to select “COB” for Blue Cutoff adjustment.
[DRIVE]
Press [4] button to select “DR” for Red Drive adjustment. Press [6] button to select “DB” for Blue Drive adjustment.
6. In each color mode, press [CHANNEL UP/DOWN] buttons to adjust the values of color.

Saturday, 6 April 2019

SYLVANIA - FUNAI - LC195SL9 B - 19 INCH LCD TV - MAIN BOARD CIRCUIT DIAGRAM

SYLVANIA - FUNAI - LC195SL9 B - 19 inch LCD TV - Main board Circuit Diagram

MAIN DIGITAL BOARD SCHEMATIC

SYLVANIA C6615LE 15 INCH COLOR LCD TELEVISION CIRCUIT DIAGRAM

SYLVANIA C6615LE 15 inch COLOR LCD TELEVISION Circuit Diagram

C6615LE 15” COLOR LCD TELEVISION Circuit Diagram. Sylvania and Funai
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.  If Main Fuse (F601) is blown, check to see that all components in the power supply circuit are not defective before you connect the AC plug to the AC power supply.  Otherwise it may cause some components in the power supply circuit to fail.
The voltage for parts in hot circuit is measured using hot GND as a common terminal.
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER SUPPLY CIRCUIT, AN ISOLATION TRANSFORMER MUST BE USED.  ALSO, IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT SLOWLY, WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY CIRCUIT, A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
SCHEMATIC DIAGRAM [Click on the Schematics to Magnify]
LCD UNIT
Main board [Contains back-light inverter and SMPS]

Wednesday, 3 April 2019

SYLVANIA & EMERSON 6227FF - EWF2705 - 27"CTV - POWER AND DEFLECTION SCHEMATIC (CIRCUIT DIAGRAM)

SYLVANIA & EMERSON 6227FF - EWF2705 - 27"CTV - POWER AND DEFLECTION SCHEMATIC (Circuit diagram)



DEFLECTION         [ CLICK ON THE SCHEMATICS TO ZOOM IN ]

POWER [SMPS]

Monday, 1 April 2019

SYLVANIA LC200SL - LC370SS8 - 20”&37" COLOR LCD TV - SERVICE MODE- POWER SUPPLY REGULATOR SCHEMATIC

SYLVANIA LC200SL - LC370SS8 - 20”&37" COLOR LCD TV - SERVICE MODE- POWER SUPPLY REGULATOR SCHEMATIC


Service Mode_Initialization_Initial Setting Values_Power Supply Regulator section Schematic & Universal Remote Control Set-up Codes. SYLVANIA LC200SL8 – 20” COLOR LCD TV
Universal Remote Control Set-up code list.
3-digit codes:  004,008,009,062,068,069,074, 075,077,155,161,163,189,198
4-digit codes0001 0321 0371 0701 0931 0961 1021 1221 1381 1801 1821 2761 1961 2321 0392
5-digit codes20675, 20821, 21268.
SERVICE MODE 
* Use the service remote control unit.
* Turn the power on. (Use main power on the TV unit.)
* Press the service button on the service remote control unit.
PREPARING A SERVICE REMOTE CONTROL OUT OF SUPPLIED REMOTE CONTROL ALONG WITH TV
Cut “A” portion of the attached remote control unit as shown.
INITIAL SETTING VALUES [DEFAULT DATA VALUES]
Enter the Service mode.  Set the each initial data as shown on table.
HOW TO INITIALIZE (Reset) THE TV
* Turn the power on. (Use main power on the TV unit.)
* To enter the service mode, press the service button on the service remote control unit.
>> To cancel the service mode, press [POWER] button on the remote control.
* To initialize the LCD television, press [DISPLAY] button on the remote control unit.
* Confirm "FF" indication on the upper right of the screen.
POWER SUPPLY REGULATOR SECTION CIRCUIT.
Fixed Voltage (or Auto voltage selectable) power supply circuit is used in this unit.  If Main Fuse (F601) is blown, first check to see that all components in the power supply circuit are not defective before you connect the AC plug to the AC power supply. Otherwise it may cause some components in the power supply circuit to fail.
CLICK ON THE SCHEMATIC TO ZOOM IN

Saturday, 30 March 2019

SYLVANIA LCT6637 - SERVICE MODE - SMPS AND BACK-LIGHT INVERTER SCHEMATIC

SYLVANIA LCT6637 - SERVICE MODE - SMPS and BACK-LIGHT INVERTER SCHEMATIC

Service Mode_Flicker Adjustment _ Initialization _ SMPS & Back-light Inverter Circuit Diagram. Used ICsOZ9938GN-B-O-T2 (Back-light inverter control) – ba10324af-e2 (Comparator) – UCC28600DR (Switching Control) – 2SK3568 (Switching output FET)
SERVICE MODE
* Use the service remote control unit.
* Turn the power on. (Use main power on the TV unit.)
* Press [SLEEP] button on the service remote control unit. The following screen appears.
To cancel the service mode, press [TV POWER] button on the remote control.
HOW TO MAKE A SERVICE REMOTE CONTROL FROM  normal remote control unit. (Part No. N0105UD or N0127UD) 
* Remove 3 Screws from the back lid.
* Add J1 (Jumper Wire) to the remote control CBA
FLICKER ADJUSTMENT
This adjustment is required when repairing T-CON CBA.
1. Enter the Service mode.
2. Press [2] button on the remote control unit. The following screen appears.
If Flicker Adjustment is not fit, the screen become the following [See the bottom picture]
Turn the VR1 on the LCD Module so that flash stops.
HOW TO INITILAIZE
1 To turn the power on, press [POWER] button on the normal remote control unit or the unit.
2 Use the service remote control unit
3 To enter the service mode, press [SLEEP] button on the service remote control unit.
 To cancel the service mode, press [TV POWER] button on the remote control.
4 To initialize the LCD television, press [DISPLAY] button on the normal remote control unit.
 “INITIALIZED” (red) appears on the screen.
 After few seconds (completion initialization), the screen is reset.
SMPS (Power) & BACK-LIGHT INVERTER SCHEMATICS
CLICK ON THE PICTURES TO MAGNIFY

Friday, 29 March 2019

MAGNAVOX - SYLVANIA AND EMERSON- 40 INCH LCD TVS - SERVICE MODE AND ADJUSTMENTS – INITIALIZE – SMPS SCHEMATIC (CIRCUIT DIAGRAM)

MAGNAVOX - SYLVANIA and EMERSON- 40 Inch LCD TVs - Service Mode and Adjustments – Initialize – SMPS Schematic (Circuit Diagram)

40” 40MF430B/F7 MAGNAVOX _ 40” 40MF430B/F7 MAGNAVOX _ 40”LC407SS1 SYLVANIA _ 40” LC407SS1 SYLVANIA _ 40” LC407SS1 SYLVANIA _ 40” LC407EM1 EMERSON
Universal Remote control Set-up codes.
MAGNAVOX: 0018 0042 0049 0101 0152 0680
EMERSON: 0004 0042 0049 0065 0101 0113 0119 0145 0152 0166 0191 0214 0215 0225 0324 0378 0421 0456 0460 0604 0611 0654
SYLVANIA:  0392
ICs used in the main power regulator board [SMPS].
MIP2F30MSSCF (Switching) _ LTV817MCF (Opto-Coupler) _ HPA00651DR ( Switching Control) _ 2SK3561 (Switching FET) _ TK5A500 (Switching FET) _ TEA1611T (High-voltage Resonant Control)
SERVICE MODE
* Turn the power on.
* Press [MENU] button to display Setup menu.
* Select “Features”.
* Select “Current Software Info”.
* Press [0] [4] [2] [5] [7] [4] & [Info] buttons on the remote control unit in this order. The following screen appears.
PURITY CHECK MODE
This mode cycles through full-screen displays of red, green, blue, and white to check for non-active pixels.
> Enter the Service mode.
> Each time pressing [7] button on the remote control unit, the display changes as follows.
WHITE BALANCE ADJUSTMENT
The White Balance Adjustment should be performed when replacing the LCD Panel or Digital Main CBA 
Purpose: To mix red, green and blue beams correctly for pure white.
Symptom of Maladjustment: White becomes bluish or reddish.
> Operate the unit for more than 20 minutes.
> Input the White Raster(70%=70IRE, 40%=40IRE)
> Set the color analyzer to the CHROMA mode and bring the optical receptor to the center on the LCD-Panel surface after zero point calibration as shown. Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
> Enter the Service mode. Press [VOLUME DOWN] button on the remote control unit and select “C/D” mode.
CUT-OFF
* Press [1] button to select “COR” for Red Cutoff adjustment. Press [3] button to select “COB” for Blue Cutoff adjustment.
DRIVE
* Press [4] button to select “DR” for Red Drive adjustment. Press [6] button to select “DB” for Blue Drive adjustment.
* In each color mode, press [CHANNEL UP/DOWN] buttons to adjust the values of color.
Adjust Cutoff and Drive so that the color temperature becomes 12000°K (x= 0.272 / y=0.278 ±0.005).
To cancel or to exit from the White Balance Adjustment, press [PREV CH] button.
HOW TO INITIALIZE THE LCD TV
The purpose of initialization is to place the set in a new out of box condition. The customer will be prompted to select a language and program channels after the set has been initialized.  To put the program back at the factory-default, initialize the LCD TV using the following procedure.
* Turn the power on.
* Enter the service mode. To cancel the service mode, press [POWER] button on the remote control unit.
* Press [INFO] button on the remote control unit to initialize the LCD television.
INITIALIZED" will appear in the upper right of the screen. "INITIALIZED" color will change to green from red when initializing is completed.
POWER SUPPLY [SMPS] SCHEMATIC (Circuit Diagram)
  Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.  If Main Fuse (F1601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.  Otherwise it may cause some components in the power supply circuit to fail.
CLICK ON THE PICTURES TO ZOOM IN