REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Friday, 29 March 2019

LITTMANN STETHOSCOPE HOW TO REMOVE AND ASSEMBLE THE DIAGRAM

LITTMANN STETHOSCOPE How to remove and assemble the Diagram

 How to remove and assemble the Diagram _ LITTMANN STETHOSCOPE
 
 
The stethoscope is most often used to listen to heart sounds and breathing. There are two basic types of stethoscopes for respiration system diagnostics of the human body. 
Acoustic Stethoscope
Acoustic stethoscopes are familiar to most people. Acoustic stethoscopes maintain their popularity and trust among doctors due to their longstanding use in the medical profession. Although it is taking digital stethoscopes time to catch up, they are rapidly gaining in popularity. However, acoustic stethoscopes are the most commonly used.
Electronic Stethoscope
Electronic stethoscopes function in a similar way as acoustic stethoscopes, but the sound is converted to electrical signals which can then be amplified and processed for optimal listening. Because the sounds are transmitted electronically, an electronic stethoscope can be a wireless device, can be a recording device, and can provide noise reduction, signal enhancement, and both visual and audio output.
ADVANTAGES & DISADVANTAGES
> In Digital stethoscope Amplifiers are used which amplifies the low level signal.
> Data can be stored for further analysis and consultation.
> Heart signal is displayed on the LCD screen.
> In digital stethoscope battery replacement can be tedious.
> They are expensive.
> They suffer from interference when other electronic instruments like cell phones are around.
PRINCIPLE OF OPERATION
The stethoscope is composed of three major parts. The first part is the chest piece, tubes and headset. It consists of a shallow, bell-shaped piece and a clear, stiff diaphragm, which is connected to the metal earpieces by a flexible tube. The bell is used to pick up lower frequency sounds, and the diaphragm is used for higher frequency sounds. When the chest piece is placed on the skin, vibrations within in the body are amplified by either the bell or diaphragm. These acoustic pressure waves then travel up through the tubing to the earpieces and into the listener’s ears. Digital stethoscopes offer new opportunities for computerized analysis of heart sounds. In cardiac auscultation, an examiner uses a stethoscope to listen to these sounds, which provide important information about the body condition. When the heart sounds are displayed graphically, the methodology is known as phonocardiography. As heart sounds are non-stationary signals, it is important to study both their temporal and frequency contents. Recently, with the rapid development of computer hardware and digital signal processing, heart sounds could be recorded and analyzed easily. The majority of these researchers mainly emphasize on the characteristic extraction by frequency-analysis method. Others concern on how to extract the heart rate from a weeping infant through the heart sound signals, and improve signal-to-noise ratio by adaptive filtering way.
Removing the Diaphragm and Cleaning the Chest-piece.
With the diaphragm side up, grasp the rim with the thumbs and index fingers of both hands and roll the rim off the edge of the chest-piece.
Remove the diaphragm from the rim and clean the parts in soapy water or wipe with alcohol. Chest-piece surfaces can be wiped with alcohol or soapy water.
Dry all parts and surfaces thoroughly before reassembly.
Assembly and Replacement of the Tunable Diaphragm
Using your fingertip, apply a small amount of talcum powder to the inside surface of the flexible edge of the diaphragm.
This will facilitate assembly and maintain smooth and quiet low/high frequency alternation.
Snap the diaphragm with your fingers to remove excess talc.
Insert the flexible edge of the diaphragm into the groove of the rim. This is best accomplished by starting with the rim positioned above the legible side of the diaphragm.
Visually examine the ring to ensure that the flexible edge is smoothly engaged inside the rim. If necessary, flex the assembly by pinching the outer rim edge. between the thumb and fingers.
Repeat this flexing procedure after rotating the assembly one quarter.
To attach the rim/diaphragm assembly to the chest-piece, engage the groove of the rim (with the diaphragm attached) around the chest-piece at one point and hold it in place with your thumbs.
Slowly roll the rim around and over the chest-piece edge using both thumbs, moving in opposite directions around the chest-piece.
Visually inspect the edge where the diaphragm engages the rim for uniform containment.
Minor adjustments may be made by slightly pulling and rolling the rim away from the diaphragm, allowing the diaphragm to slip into position.
Avoid extreme heat, cold, solvents, and oils.
Do not immerse your stethoscope in any liquid or subject it to steam sterilization. If disinfection is required, the stethoscope may be wiped with a 70% isopropyl alcohol solution. Wipe and clean with alcohol or soap water.