PANASONIC 4K Video Camera HC-X1000 - Service mode – Error codes – Touch panel calibration – Memory Battery replacement – Digital Camera Repair and service
Category: Digital Camera Repair and Service
Contents of this article
- How to access service mode
- Service mode adjustments
- Error codes
- Memory battery replacement
PANASONIC HC-X1000
Service Mode
Indication method of the service menu
1. Set the power switch to ON, and turn to ON.
2. While pressing the “MENU”button to “FOCUS ASSIST”button and “Zoom Lever” (or “Sub zoom lever”) to W side for more than 3 seconds until the top screen of the Service Mode Menu being displayed.
1. Set the power switch to ON, and turn to ON.
2. While pressing the “MENU”button to “FOCUS ASSIST”button and “Zoom Lever” (or “Sub zoom lever”) to W side for more than 3 seconds until the top screen of the Service Mode Menu being displayed.
Service mode menu
Screen display
|
Contents
|
Function
|
1
|
Factory
settings
|
Function
to throw a product up in a factory shipment state.
|
2
|
Model/Destination
settings
|
Change
the Model/Destination.
(Selectable models and destinations are displayed.) |
4
|
Lock
search history indication
|
Display
the camera system and fan system error code for three
histories saved in EEPROM. |
5
|
Power
ON self check result display
|
Power
ON self check (function to diagnose correct function of the
device and interface between devices) result display. |
14
|
Adjutment
function for the service
|
The
service adjustment do setup and adjustment of the following
items required in the field service. |
15
|
Restore
the backed up adjustment data
|
Restore
the adjustment data to new or repaired Main P.C.B. from
SD card that the data backed up from original Main P.C.B. before repairs or replacement. |
16
|
Touch
panel calibration
|
Calibrate
the touch positions of the touch panel.
|
17
|
NFC
initialization
|
Performs
the Initialization of the NFC chip and erase the settings
like as Wi-Fi connection etc.. |
NOTE:
Do not using service mode except above table of Service mode menu.
3. End method of the top screen of the service mode menu
Touch the [ EXIT ] of LCD to end the service mode, and then POWER OFF.
3. End method of the top screen of the service mode menu
Touch the [ EXIT ] of LCD to end the service mode, and then POWER OFF.
Model/Destination Settings
Touch the [ 2 ] of LCD, select model/destination settings.
Touch the [ 2 ] of LCD, select model/destination settings.
Function description
# Change the Model/Destination
Display the lists of model/distination which the unit can be changed, if a shipment setup is finished.
Therefore in some cases, the model/destination that is currently set is only displayed.
End method of operation
# Touch the [ SET ] of LCD to exit the mode/destination settings, and then POWER OFF.
# Change the Model/Destination
Display the lists of model/distination which the unit can be changed, if a shipment setup is finished.
Therefore in some cases, the model/destination that is currently set is only displayed.
End method of operation
# Touch the [ SET ] of LCD to exit the mode/destination settings, and then POWER OFF.
Lock Search and Error History
Indication
Touch the [ 4 ] of LCD, select Lock search and error history indication.
Touch the [ 4 ] of LCD, select Lock search and error history indication.
Indication contents
# Lock search history indication of camera
Display the camera system and fan system error code for three histories saved in EEPROM.
# The error code contents which are displayed
# Lock search history indication of camera
Display the camera system and fan system error code for three histories saved in EEPROM.
# The error code contents which are displayed
Error code
|
Description
|
51
|
Focus
control is abnormal
|
52
|
Zoom
control is abnormal
|
53
|
OIS
lens control is abnormal
|
54
|
Zoom
control is abnormal (2)
|
55
|
Zoom
control is abnormal (3)
|
72
|
Fan
is abnormal
|
End method of operation
# Touch the [ BAK ] of LCD to exit the lock search and error history
indication, and then POWER OFF.
Power ON Self Check Result
Display
Touch the [ 5 ] of LCD, select Power ON self check result display.
Touch the [ 5 ] of LCD, select Power ON self check result display.
Indication contents
# Power ON self check result display
Function to diagnose correct function of the device and interface between devices result display.
Display the following communication test result.
- Power IC : Communication test between IC3401 and IC2303
- Main IC : DDR. Communication test inside IC3401
- WiFi IC : Communication test between IC3401 and Wi-Fi Module
- NFC IC : Communication test between IC3401 and NFC P.C.B. Unit
Display other than “OK” are abnomalities of each lines.
End method of operation
# Touch the [ BAK ] of LCD to exit the power on self check result display, and the POWER OFF.
# Power ON self check result display
Function to diagnose correct function of the device and interface between devices result display.
Display the following communication test result.
- Power IC : Communication test between IC3401 and IC2303
- Main IC : DDR. Communication test inside IC3401
- WiFi IC : Communication test between IC3401 and Wi-Fi Module
- NFC IC : Communication test between IC3401 and NFC P.C.B. Unit
Display other than “OK” are abnomalities of each lines.
End method of operation
# Touch the [ BAK ] of LCD to exit the power on self check result display, and the POWER OFF.
Adjustment function for the
Service
Touch the [14] of LCD, select the adjustment function for the service.
Touch the [14] of LCD, select the adjustment function for the service.
Function description
The service adjustment do setup and adjustment of the following items required in the field service.
For a detailed content, such as the adjustment procedure, refer to “9 Measurements and Adjustments”.
# Model setting
# Setting of the file name for adjustment data backup to SD card
# Execution of adjustment data backup to SD card
# Checking of Switches
# Zoom Lever adjustment
# Camera adjustment (Iris, Gyro, OIS and White Missing pixels)
# Zoom/Tracking adjustment (with Zoom hysteresis adjustment), ND Focus adjustment
# ND WB GAIN adjustment
# Indoor White Balance Adjustment (SHADING, CH-GAIN, PWM, WB)
# Outdoor White Balance Adjustment (PWM, WB)
# Level shot adjustment
End method of operation
# Set the power switch to OFF to turn the unit off.
The service adjustment do setup and adjustment of the following items required in the field service.
For a detailed content, such as the adjustment procedure, refer to “9 Measurements and Adjustments”.
# Model setting
# Setting of the file name for adjustment data backup to SD card
# Execution of adjustment data backup to SD card
# Checking of Switches
# Zoom Lever adjustment
# Camera adjustment (Iris, Gyro, OIS and White Missing pixels)
# Zoom/Tracking adjustment (with Zoom hysteresis adjustment), ND Focus adjustment
# ND WB GAIN adjustment
# Indoor White Balance Adjustment (SHADING, CH-GAIN, PWM, WB)
# Outdoor White Balance Adjustment (PWM, WB)
# Level shot adjustment
End method of operation
# Set the power switch to OFF to turn the unit off.
Restore the backed up adjustment
data
Touch the [15] of LCD, select restoring the backed up adjustment data from SD card to the unit.
Touch the [15] of LCD, select restoring the backed up adjustment data from SD card to the unit.
Function description
Restore the adjustment data to new or repaired Main P.C.B. from SD card that the data backed up from original Main P.C.B.
before repairs or replacement.
To backup the adjustment data, use “6.4. Adjustment function for the Service”.
Restore the adjustment data to new or repaired Main P.C.B. from SD card that the data backed up from original Main P.C.B.
before repairs or replacement.
To backup the adjustment data, use “6.4. Adjustment function for the Service”.
End method of operation
# Set the power switch to OFF to turn the unit off
# Set the power switch to OFF to turn the unit off
Touch Panel Calibration
Touch the [16] of LCD, select the calibration of touch panel.
Touch the [16] of LCD, select the calibration of touch panel.
Function description
Calibrate the touch positions of the touch panel.
End method of operation
# Set the power switch to OFF to turn the unit off.
NFC Initialization
Touch the [17] of LCD, select initialization of NFC (Near Field Communication) function.
Calibrate the touch positions of the touch panel.
End method of operation
# Set the power switch to OFF to turn the unit off.
NFC Initialization
Touch the [17] of LCD, select initialization of NFC (Near Field Communication) function.
Function description
This function performs the Initialization of the NFC chip and erase the settings like as Wi-Fi connection etc..
End method of operation
# Set the power switch to OFF to turn the unit off.
This function performs the Initialization of the NFC chip and erase the settings like as Wi-Fi connection etc..
End method of operation
# Set the power switch to OFF to turn the unit off.
How to Replace the Lithium Battery
Replacement Procedure
1. Remove the SIDE R OPERATION P.C.B.. (Refer to Disassembly Procedures.)
2. Remove the Lithium battery (Ref. No. “B6951” at foil side of SIDE R OPERATION P.C.B.) and then replace it into new one.
Replacement Procedure
1. Remove the SIDE R OPERATION P.C.B.. (Refer to Disassembly Procedures.)
2. Remove the Lithium battery (Ref. No. “B6951” at foil side of SIDE R OPERATION P.C.B.) and then replace it into new one.
NOTE:
This Lithium battery is a critical component.
It must never be subjected to excessive heat or discharge.
It must therefore only be fitted in requirement designed specifically for its use.
Replacement batteries must be of same type and manufacture.
They must be fitted in the same manner and location as the original battery, with the correct polarity contacts observed.
Do not attempt to re-charge the old battery or re-use it for any other purpose.
It should be disposed of in waste products destined for burial rather than incineration.
This Lithium battery is a critical component.
It must never be subjected to excessive heat or discharge.
It must therefore only be fitted in requirement designed specifically for its use.
Replacement batteries must be of same type and manufacture.
They must be fitted in the same manner and location as the original battery, with the correct polarity contacts observed.
Do not attempt to re-charge the old battery or re-use it for any other purpose.
It should be disposed of in waste products destined for burial rather than incineration.