If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Monday 11 March 2019

SHARP LC-32D44 SERVICE MODE AND FACTORY RESET

SHARP LC-32D44 SERVICE MODE AND FACTORY RESET


SHARP  LC-32D44 

SERVICE MODE AND FACTORY RESET


HOW TO ENTER TO SERVICE MODE 
1) Before entering the adjustment process mode, the AV position RESET in the video adjustment menu.
2) While holding down the “VOL (–)” and “INPUT” keys at a time, plug in the AC cord of the main unit to turn on the power.
The letter “<K>” appears on the screen.
3) Next, hold down the “VOL (–)” and “CH ( V )” keys at a time.
(The “VOL (–)” and “CH ( V )” keys should be pressed and held until the display appears.)
Multiple lines of blue characters appearing on the display indicate that the unit is now in the adjustment process mode.

When you fail to enter the adjustment process mode (the display is the same as normal startup), retry the procedure.
4) To exit the adjustment process mode after the adjustment is done, unplug the AC cord from the outlet to make a forced shutdown. (When the power was turned off with the remote controller, once unplug the AC cord and plug it again. In this case, wait 10 seconds or so before plugging.)
CAUTION: Use due care in handling the information described here lest your users should know how to enter the adjustment process mode. If the settings are tampered in this mode, unrecoverable system damage may result.
How to adjust the White balance of the TV
Automatic adjustment execution
[Adjustment procedure]
1) Using the remote controller, transmit the “monitor adjustment process” code.
2) Set the 6th point to the specified gradation level. With the strongest color being fixed, turn down the R, G and B settings to their reference levels.
3) Set the 5th point to the specified gradation level. Correct the G setting (800 x 6thpoint G setting / 928) (rounded off), and make the R and B settings to their reference levels.
4) Set the 4th point to the specified gradation level. Correct the G setting (680 x 6thpoint G setting / 928) (rounded off), and make the R and B settings to their reference levels.
5) Set the 3rd point to the specified gradation level. Correct the G setting (480 x 6thpoint G setting / 928) (rounded off), and make the R and B settings to their reference levels.
6) Set the 2nd point to the specified gradation level. Correct the G setting (232 x 6thpoint G setting / 928) (rounded off), and make the R and B settings to their reference levels.
7) Set the 1st point to the specified gradation level. Correct the G setting (184 x 6thpoint G setting / 928) (rounded off), and make the R and B settings to their reference levels.
8) With the MSET0003 command, write the adjustment values and turn off the AC power.
* Initial R, G and B settings at point 6: Gradation level set at 928
* Initial R, G and B settings at points 1 thru 5: Corrected G setting at each point
(This is because the adjustment is made to achieve the same remainder of RGB setting / 4 at each point.)
[Adjustment value]
•As per the “standard set” submitted by Engineering Department
“LC-32D44U” Teaching set
[Adjustment reference] Instrument: Minolta CA-210 Engineering instrument.

How to do factory reset 
After making the factory settings, pull off the AC cord.
NOTE: Do not turn on the power once the factory settings have been made. Otherwise the factory settings must be made again.
Move the cursor to the [INDUSTRY INIT (+Cause)] line. Using the [VOL+/-] keys, set this item ON and press the [ENT] key.
The version confirm window appears on the green screen. When [SUCCESS] appears at the top, the factory settings are complete. (If an error occurs. [ERROR] appears on the red screen.)
Finally turn off the AC power.
The following settings are returned to the factory ones.
1) User settings
2) Channel data (broadcast frequencies, etc.)
3) Password setting
4) Operation time
5) Automatic installation flag
6) V-CHIP block setting
How to upgrade Monitor microprocessor software version 
Create the USB memory for monitor microprocessor software version upgrade in the same manner as explained in the “Main software version upgrade”.
Copy the file D44UVAxxx.USB and D44UMxxx.BIN (named temporarily) for monitor microprocessor software version upgrade to the USB memory.
How to upgrade the software
1. Unplug the AC cord.
2. Insert the USB memory for version upgrade (prepared as above) into the service socket located Right side from center at terminals, above HDMI4 terminal in the rear of the unit.
3. Plug in the AC cord with power button pressed down.
4. After 5 seconds, unpress the power button.
CAUTION: • The moment this operation is done, the upgrading of the monitor microprocessor software starts. While the upgrade is ongoing, never power off the unit. Otherwise the upgrade will fail and the system may be serious damaged beyond recovery (inability to start).
• After the monitor microprocessor software is upgraded, also perform the 'Industry Init'.
5. After the unit startup, the upgrade starts. The power led will blink continuously. Also, an upgrade screen will be shown during a minor upgrade.
6. If the upgrade fails, power led will stop blinking. Also, the upgrade failure screen will be show.
NOTE: In the event of a transient failure, upgrade will be automatically retried up to three times. If the process repeatedly fails, hardware may be the cause.
7. Up on completion of the whole process, power and OPC LED will blink alternately. Also, the upgrade success screen will be shown if upgrade screen was show.
8. Unplug the AC cord and remove the USB Memory for version upgrade.
9. Now the software version upgrade is complete.
NOTE: When you are done with the software version upgrade, start the set, go to the top page of the adjustment process screen and check the monitor microprocessor software version information and panel size information.
How to upgrade Panel timing controller software
Create the USB memory for Panel timing controller software version upgrade in the same manner as explained in the “Main software version upgrade.”
Copy the file D44UAxxx.USB and D44UAxxx.TCN to USB memory.
How to upgrade the software
1. Unplug the AC cord.
2. Insert the USB Memory for version upgrade (prepared as above) into the service socket located Right side from center at terminals, above HDMI4 terminal in the rear of the unit.
3. Plug in the AC cord with power button pressed down after 5 seconds, unpress the power button.
4. After the unit startup, the upgrade starts. The screen is not shown. This take about a minute.
5. When there is an error, ‘PANEL EEPROM’ field display the type. Ignore ‘UPGRADE SUCCESS’ that is displayed at the top.
6. Upon completion of the whole process, the upgrade success screen as shown below appears. You can check the new software version on this screen. The version information appears after the upgrade is complete.
7. Unplug the AC cord and remove the USB Memory for version upgrade.