REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Friday 22 March 2019

SONY KV-21FS120 - KV-24FS120 - LED BLINKING CODES - DISASSEMBLY

SONY KV-21FS120 - KV-24FS120 - LED BLINKING CODES - DISASSEMBLY




APPLICABLE TO:  SONY 

KV-20FS120 RM-Y194 US SCC- S61K-A,
KV-20FS120 RM-Y194 CND SCC- S59H-A,
KV-21FM120 RM-W151 LATIN NORTH SCC- S60X-A,
KV-21FS120 RM-Y194 LATIN NORTH SCC- S60Y-A,
KV-21FS120 RM-Y194 LATIN SOUTH SCC- S73A-A
KV-21FA310 RM-Y180 LATIN NORTH SCC- S60T-A,
KV-21FA310 RM-Y180 LATIN SOUTH SCC- S60U-A,
KV-24FS120 RM-Y194 US SCC- S61L-A,
KV-24FS120 RM-Y194 CND SCC- S59J-A,
KV-25FS120 RM-Y194 LATIN NORTH SCC- S73B-A
KV-25FS120 RM-Y194 LATIN SOUTH SCC- S73C-A.
  • When an error occurs, the STANDBY/TIMER LED will fl ash a set number of times to indicate the possible cause of the problem. If there is more than one error, the LED will identify the first of the problem areas.  Results for all of the following diagnostic items are displayed on screen. No error has occurred if the screen displays a “0”.
  • If a +B over current is detected, stoppage of the vertical deflection is detected simultaneously. The symptom that is diagnosed first by the micro controller is displayed on the screen.
Diagnostic Item Flash Count [One fl ash count is not used for self-diagnostic.]
+B Overcurrent  à 2 times
I-Prot  à  4 times
IK (AKB)  à 5 times.
Self-Diagnostic Screen Display
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confirmed, it is possible to bring up past occurrences of failure on the screen for confirmation.
To Bring Up Screen Test
In standby mode, press buttons on the Remote Commander sequentially, in rapid succession, as shown below:
[DISPLAY] à [CHANNEL-5] à [SOUND VOLUME (-Ve)] à [POWER ON].
Handling of Self-Diagnostic Screen Display
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen during repairs. When you have completed the repairs, clear the result display to “0”.  Unless the result display is cleared to “0”, the self-diagnostic function will not be able to detect subsequent faults after completion of the repairs.

Clearing the Result Display
To clear the result display to “0”, press buttons on the Remote Commander sequentially when the diagnostic screen is displayed, as shown below:
[Channel 8] à  ENTER]
Quitting the Self-Diagnostic Screen
To quit the entire self-diagnostic screen, turn off the power switch on the Remote Commander or the main unit.
+B over current (OCP)
Occurs when an over current on the +B (135V) line is detected by pin 72 of IC001 (A Board). If the voltage of pin 72 of IC001 (A Board) is less than 1V when V.SYNC is more than seven verticals in a period, the unit will automatically turn off.
I-Prot
Occurs when an absence of the vertical defl ection pulse is detected by pin 78 of IC001 (A Board). Power supply will shut down when waveform interval exceeds 2 seconds.
IK (AKB)
If the RGB levels* do not balance within 2 seconds after the power is turned on, this error will be detected by IC001 (A Board). TV will stay on, but there will be no picture.
LED BLINKING CODES [DETAILS]


Diagnostic Item
Description
No. of times
STANDBY/ TIMER
lamp flashes

Self-Diagnostic
Display/Diagnostic Result


Probable Cause Location

Detected Symptoms


Power does not turn on



Does not light



  ----------
• Power cord is not plugged in.
• Fuse is burned out (F601). (A Board)
• Power does not come on.
• No power is supplied to the TV.
• AC Power supply is faulty.





+B over current (OCP)





2 times





2:0 or 2:1
• H.OUT (Q506) is shorted. (A Board) (20”/21” models only)
H.OUT (Q505) is shorted. (A Board) (24”/25” models only)
• RGB Amp (IC1751) is shorted. (CV Board)




• Power does not come on.
• Load on power line is shorted.




I-Prot




4 times




4:0 or 4:1


• +13V is not supplied. (A Board)
• IC545 is faulty. (A Board)
• Has entered standby state after horizontal raster.
• Vertical defl ection pulse is stopped.
• Power line is shorted or power supply is stopped.




IK (AKB)



5 times



5:0 or 5:1
• Video OUT (IC545) is faulty.
(A Board)
• IC001 is faulty. (A Board)
• Screen (G2) is improperly adjusted
• No raster is generated.
• CRT Cathode current detection reference pulse
output is small.
DISASSEMBLEY
REAR COVER REMOVAL (ALL EXCEPT KV-21FA310)
Remove screws.


REAR COVER REMOVAL (KV-21FA310 ONLY)
Lift to remove Sub-woofer.
Remove screws.

CHASSIS REMOVAL
SERVICE POSITION
  • Push down on clips to release K Board, then unplug the 2 pin woofer connector and move out of the way.
  • Press on catch tab to release A Board.
  • Disconnect remaining cables to allow A Board to be removed.