REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Monday 4 March 2019

SPORTS ART T652 TREADMILL - ERROR CODE AND SOLUTION – TROUBLESHOOTING – TREADMILL REPAIR AND SERVICE

Sports Art T652 Treadmill - Error code and solution – Troubleshooting – Treadmill repair and service

Category: Treadmill Repair and Service 

Contents of this article 

  • Error code and solution
  • Common troubles and  solutions   
  • Troubleshooting electrical parts 


Sports Art T652

Safety key operation is malfunctioning
Put Safety key in place. There is no reaction from the display. “Safety Key” error message appears.
1. Inspect the cable connections at the bridge board and safety key
2. Replace the safety key.
Replace
Safety key board
No start up
Turn on the power. Display shows no reaction.
1. Inspect main fuse.
2. Inspect drive board fuse and LED.
3. Inspect all cable connections.
4. Inspect display LED and program IC.
Replace
1. Main unit fuse
2. Drive board
3. Cables
4. Display
No incline operation
Press incline keys. The incline does not operate up or down.
1. Inspect incline 0% switch.
2. Inspect drive board cable connections.
3. Replace drive board.
4. Incline motor malfunction.
Replace
1. Drive board
2. 0% switch
No telemetry heart rate reception
Telemetry heart rate does not function.
1. Inspect heart rate transmitter strap and battery. Replace the battery if the strap has not been used for a long time.
2. Inspect heart rate receiver board cable connection.
3. Inspect or replace the telemetry heart rate receiver board.
4. Inspect environment for interference, such as speakers and lights
Replace
1. Heart rate transmitter
2. Heart rate receiver
No contact heart rate reception
Contact heart rate does not function.
1. Inspect the HTR cable connection to the bridge board.
2. Inspect the HTR indicator LEDs.
3. Replace the HTR board.
Replace
1.HTR board
Key malfunction (display)
Keys do not operate or keys operate continuously.
1. Replace the display key switches.
Replace
Display board key switches
Key malfunction (soft key)
Keys do not operate or keys operate continuously.
1. Inspect the soft key cable connection on the bridge board.
2. Replace the soft key.
Replace
Soft keys
ERR0R_1_1_ Servo motor encoder malfunction
1. If motor does not rotate, the EAC drive board could be the issue.
2. If the motor rotates and ERROR_1_1_ appears, replace the motor speed sensor.
Replace
1. EAC drive board
2. Servo encoder
ERR0R_1_2_
Servo motor thermal sensor is activated; speed is reduced to half speed.
1. Inspect motor temperature. If it is not hot, inspect the thermal sensor cable connection.
2. Inspect walk belt tightness. 3. Inspect walk belt wear.
4. Lubricate the belt. If lubrication is not effective, replace the walk belt..
Replace
1. Walk belt
ERROR_2_1_
IGBT over current malfunction
1. Re-start the unit as a test.
2. If issue is repeated, replace the EAC drive board.
Replace
1. EAC drive board
ERR0R_2_2_ 
IGBTover heat malfunction
1. Re-start the unit as a test.
2. If issue is repeated, replace the EAC drive board.
Replace
1. EAC drive board
ERROR_3_1_
Incline motor calibration malfunction
1. Inspect cable connections.
2. After starting the unit, feel the incline motor. If hot, the drive board is malfunctioning.
3. After starting the unit, inspect whether incline 0% switch operates. If so, the drive board is malfunctioning.
 4. Inspect the 0% switch operation.
Replace
1.EAC drive board 2.Incline 0% switch
Power off
Power is off.
1. Re-start the unit as a test.
2. If issue is repeated, replace the EAC drive board.
Replace
1. EAC drive board
ERR0R_4_2_
Low voltage supply
1. Power supply is too low.
2. Measure power supply voltage. If too low, external power supply is insufficient. Please have an electrician address the situation.
3. After fixing the power supply, use the product to confirm its safety.
ERROR_4_3_
High voltage supply
1. External power supply voltage is too high.
2. Turn off unit. Re-start the unit. If the message still appears, this may be a time period of low voltage use, creating excessive voltage. This issue often occurs in industrial areas.
3. For safety, wait until the power supply voltage drops before using the unit.
ERROR_8_1_
Communication error at start up
1. Cables are not connected.
2. EAC drive board is malfunctioning.
Replace
1. EAC drive board
ERROR_8_2_
Communication error after start up
1. Inspect for environmental interference.
2. Inspect power supply for an actual ground.
3. Replace the EAC drive board.
Replace
1. EAC drive board
Main fuse breaks.
During use, main fuse suddenly breaks.
1. Inspect the main power supply for low voltage. Normal is 110v (N. America) or 220v (Europe) +-10%.
2. Inspect whether walk belt is excessively tight.
3. Inspect the walk belt and deck for wear. Lubricate the walk belt.
4. Inspect the fuse holder and fuse.
5. Replace the EAC drive board as a test.
Replace
1. Walk belt
2. EAC drive board
Safety key malfunction
Circumstance: Put the safety key in place; the display shows no reaction; “Safety key” error message appears.
Possible causes: Safety key board malfunction
Troubleshooting: 1. Inspect the safety key magnet.
2. Inspect the bridge board wire connections.
3. Test or replace the safety key board.
Unit will not start operating.
Circumstance: Turn POWER ON; the display does not light.
Possible cause: Incoming power issue; component failure.
Troubleshooting:
1. Inspect the main fuse and power switch.
 2. Inspect all cable connections.
3. Inspect drive board power LED. Or replace the drive board as a test.
4. Inspect the display power LED and main IC.
Telemetry heart rate malfunction
Circumstance: Telemetry heart rate reading does not appear or the value is incorrect.
Possible cause:
1. Telemetry heart rate batteries
2. Heart rate receiver
3. Environmental interference, for example, lights and speakers
Troubleshooting:
1. Replace telemetry heart rate transmitter or its batteries
2. Inspect telemetry receiver board cable connections
3. Replace the telemetry receiver board as a test.
Soft key malfunction
Circumstance: Press display board keys. There is no reaction, or keys operate continuously.
Possible causes:
1. Soft keys are not connected properly at the bridge board.
2. Soft keys are bad.
Troubleshooting:
1. Inspect the soft key connection at the bridge board.
2. Replace the soft keys.
Key malfunction – display keys
Circumstance: Press display keys; there is no reaction; Or keys operate continuously.
Possible causes:
1. Display key switch malfunction: SW1-SW25.
2. Key cushions are out of place.
Troubleshooting:
1. Inspect key cushions.
2. Replace display key switches.