TCL 42E5300 MS82S-AP SERVICE MODE AND SOFTWARE UPDATE
TCL 42E5300 MS82S-AP
SERVICE MODE AND SOFTWARE UPDATE
SERVICE
MODE
Accessing way:
a. In the first place, press Menu button of remote
control, then select Contrast item of Picture submenu. Finally,
press 9, 7, 3, 5 consecutively.
b. When the FAC HOTKEY item of Factory Menu is
enabled (ON), press Return button of remote control.
ADC Menu
Press the UP DOWN button in remote control to select certainitem and RIGHT AND LEFT to change the value of ADC data or start ADC calibration.
Notes: Only YPBPR and RGB source should be calibrated.
Press the UP DOWN button in remote control to select certainitem and RIGHT AND LEFT to change the value of ADC data or start ADC calibration.
Notes: Only YPBPR and RGB source should be calibrated.
CLICK ON THE IMAGE TOP ZOOM IN
White Balance menu
Press the UP DOWN button in remote control to select certain item and RIGHT AND LEFT to adjust White Balance
Press the UP DOWN button in remote control to select certain item and RIGHT AND LEFT to adjust White Balance
CLICK ON THE IMAGE TOP ZOOM IN
Factory Main Menu
Accessing way:
1. In the first place, press Menu button of remote
control, then select Contrast item of Picture submenu. Finally,
press 1, 9, 5, 0 consecutively.
2. When the DESIGN
HOTKEY item of Design Menu is enabled (ON), press Return button
of remote control.
Press
the UP DOWN button in remote control to select certain item and RIGHT AND LEFT to toggle
among or execute the available options.
CLICK ON THE IMAGE TOP ZOOM IN
SHOP MENU
Contain
many options which can be chosen according to the requirements of customers as default
settings when leave factory. Press the UP DOWN button in remote control to select
certain item and RIGHT AND LEFT to toggle among the available options.
CLICK ON THE IMAGE TOP ZOOM IN
Steps of debugging:
According to the requirement of order, we suggest take the
below steps to finish the appropriate settings.
A. Enter the Factory Menu, enable FAC HOTKEY
B. Check the version of software, release date displayed at
the bottom of Factory Menu. If the information is correct, you
can ignore step C and D.
C. Enter Factory
Main Menu, choose SERVICE MENU->PROJECT ID, choose corresponding
Project ID number of the product (Please refer to the description in BOM about
Project ID number).
D. Return to Factory
Menu, check the Product model.
E.Choose Factory Menu-> NVM RESET and press and
wait until prompt OK appears.
F. Restart the set G according to the requirement of order,
set the items of Shop Menu and Hotel Menu etc.
H. After aging under normal temperature, calibrate ADC and
adjust white balance. I choose Factory Menu-> SHOP INIT and press
button of remote control to initialize the set.
Note: after step I (execute SHOP INIT), Hotel Menu will be disabled by default. Therefore, if order requires hotel function, it is necessary to enable hotel function by set Factory Main Menu-> Service Menu->HOTEL ENABLE to ON.
Note: after step I (execute SHOP INIT), Hotel Menu will be disabled by default. Therefore, if order requires hotel function, it is necessary to enable hotel function by set Factory Main Menu-> Service Menu->HOTEL ENABLE to ON.
White Balance adjustment (Manual)
Before adjustment, you must ensure Color Analyzer has been
calibrated. Only AV1, YPBPR, VGA , HDMI 1 need to be adjusted. It is necessary
to adjustment HDMI 1 firstly.
a. Signal and generator The pattern of the signal should be used are White (Chroma2329 pattern113) and Grey (pattern 114).The format of signal are respectively 720p for HDMI1 (Chroma2329 Timing 69), NTSC for AV1 (Chroma2329 Timing 37),1024×768@60Hz (Chroma2329 Timing 14) for VGA and 720p (Chroma2329 Timing 79)for YPBPR.
a. Signal and generator The pattern of the signal should be used are White (Chroma2329 pattern113) and Grey (pattern 114).The format of signal are respectively 720p for HDMI1 (Chroma2329 Timing 69), NTSC for AV1 (Chroma2329 Timing 37),1024×768@60Hz (Chroma2329 Timing 14) for VGA and 720p (Chroma2329 Timing 79)for YPBPR.
b. Steps of adjustment
1) Enter the factory
menu->WHITE BALANCE, select source HDMI 1 and COLORTEMP normal.
2) Input grey signal in 720p format
3) Change R OFFSET and B OFFSET to make sure
the value of color coordination equal to the value required by enterprise
standard (x, y).
4) Input white signal in 720p format
5) Change R Gain and B Gain to make sure the value
of color coordination equal to (x, y).
6) Repeat step 2>5 until both of the value of color
coordination of white and grey equal to (x, y). In addition to select COLORTEMP
COOL/WARM, the adjustment method of COOL and WARM color
temperature is same with that of NORMAL.
ADC Calibration and White Balance Adjustment
(automatic)
The process of adjusting ADC and White Balance automatically
is out of the range of this file. Please refer to the relevant technical file
of HuiZhou factory of TCL.
Software upgrade through USB disk
1) Please ensure the software you are using has a correct
file name TCL_MS82_UPDATE.bin, then copy it to the root directory of a
USB disk.
2) Insert the USB disk to the USB socket of the set for
which you are going to upgrade program.
3) Enter the Factory Menu (you can choose either a or
b way below) a. In the first place, press Menu button of remote
control, then select Contrast item of Picture submenu. Finally,
press 9, 7, 3, 5 consecutively. b. When the Factory hotkey item
of Factory Menu is enabled (ON), press Return button of remote
control.
4) select USB UPDATE, press RIGHT Bbutton of remote
control, a pop menu will appear prompting whether start upgradeor not. Press Yes
to start upgrade, press No to canel. Please wait patiently until
the set restart automatically after upgrade. Do not cut off the power
supply during the process.
Check software version, release date and Project
ID
After upgrading, sometimes you may not certain whether the new software has
been successfully updated or not. In this case, you can check the software
version and release date in Factory Main Menu to make sure the success
of upgrading. In addition, for the convenience of software management, many
models of same chassis may share a same software, but are allocated with
different Project ID. In another words, every model has its unique Project ID.
Obviously, Both software version and Project ID are highly critical to ensure
the set work properly. Therefore, after upgrading software,we suggest you check
these information by following method.
1) Enter the Factory Main Menu(you can choose either
a or b way below a In the first place, press Menu button of remote
control, then select Contrast item of Picture submenu. Finally,
press 1, 9 5, 0 consecutively. b. When the DESIGN HOTKEY item of Factory
Main Menu is enabled (ON), press Return button of remote control.
2) Check the version of software, release date displayed at
the bottom of Factory
Main Menu. If the information is correct, you can ignore step C and D.
Main Menu. If the information is correct, you can ignore step C and D.
3) choose SERVICE MENU->PROJECT ID, choose corresponding
Project ID number of the product (Please refer to the description in BOM about
Project ID number).
4) choose Factory Menu and press OK button of
the remote. Next, select NVM RESET and press and wait until prompt
OK appears. 5) choose SHOP INIT and press button of remote control to
initialize the set.
Note: after step I (execute SHOP INIT), Hotel Menu will be disabled by default. Therefore, if order requires hotel function, it is necessary to enable hotel function by set Factory Main Menu-> Service Menu->HOTEL ENABLE to ON.
Note: after step I (execute SHOP INIT), Hotel Menu will be disabled by default. Therefore, if order requires hotel function, it is necessary to enable hotel function by set Factory Main Menu-> Service Menu->HOTEL ENABLE to ON.