ACER X203H - 20" LCD MONITOR HOW TO UPGRADES SOFTWARE/FIRMWARE _ EDID UPGRADE
Hardware Requirement
- ISP Board-1
- DSUB VGA cables x 2
- Printer cable ( with one male connector and another female connector) x 1.
- PC or Notebook with parallel (printer) port x1.
Un-zip ISP
application tool (RTDTool)
Press “RTD 2120 ISP” button to execute e firmware program
application.
Press “64K” button to load *series*. hex file and press
“64~96” button to load *extend*.hex file from your computer.
Select “Erase” option
and execute e lightning butt on first, and t hen select “Auto” option and execute
e lightning button to start upgrade firmware to the monitor.
CLICK ON THE PICTURES TO ZOOM
You can change program speed bar to meet your equipment
speed if program firmware e fail.
IF the monitor without signal input has Burn In pattern. As
t he following figure:
Press “MENU” and
“>” key at t he same time to exit Burn in mode (factory mode), and
soft power key off/ on restart the monitor.
EDID UPGRADE
Run the program “Q-EDID-V012.exe”, when the UI popped up.
If “VGA” choose
128bytes, and “DVI ” choose 128bytes.
Click “Open File” and select “ VGA” or “DVI” EDID file.
If load file is successful, it shows “Open EDID Table OK..”.
And then, Click “Write EDID” button to update EDID.
If write EDID is successful, it shows” Write EDID OK …” And
then, Click “Read EDID” but ton to check if successful or not.
If read EDID is successful, it shows” Read EDID OK …”