REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Thursday, 7 March 2019

EPSON STYLUS PRO 10000 ERROR CODES

EPSON STYLUS PRO 10000 Error codes

EPSON STYLUS PRO 10000

ERROR CODES 
SERVICE CALL 00,010,015: INK SURFACE SENSOR (K) OVERFLOW
Surface of a liquid sensor defective or I/C valve solenoid defective it is (on condition).
• I/C valve solenoid exchange 
• C362DRV board exchange 
• Surface of a liquid sensor exchanger
SERVICE CALL 00,010,016: INK SURFACE SENSOR (C) OVERFLOW
Surface of a liquid sensor defective or I/C valve solenoid defective it is (on condition).
• I/C valve solenoid exchange 
• C362DRV board exchange 
• Surface of a liquid sensor exchanger
SERVICE CALL 00,010,017: INK SURFACE SENSOR (M) OVERFLOW
Surface of a liquid sensor defective or I/C valve solenoid defective it is (on condition).
• I/C valve solenoid exchange 
• C362DRV board exchange 
• Surface of a liquid sensor exchanger
SERVICE CALL 00,010,018: INK SURFACE SENSOR (LC) OVERFLOW
Surface of a liquid sensor defective or I/C valve solenoid defective it is (on condition).
• I/C valve solenoid exchange 
• C362DRV board exchange 
• Surface of a liquid sensor exchanger
SERVICE CALL 00,010,019: INK SURFACE SENSOR (LM) OVERFLOW
Surface of a liquid sensor defective or I/C valve solenoid defective it is (on condition).
• I/C valve solenoid exchange 
• C362DRV board exchange 
• Surface of a liquid sensor exchanger
SERVICE CALL 00000100:Waste ink tank full
The waste ink pads are completely full, causing a fatal error. The printer stops printing.
It is similar as "Maintenance call 0100".
SERVICE CALL 00000101: CR motor life (Even Ink tube life)
The carriage drive system reached the life.
The following confirmation and also part exchange and CR motor initialization 
• Whether there is not ink leakage from the ink supply tube and also coupling department, is confirmed. 
• It confirms whether there are not dirt and abrasion in the slowing-down gear that was attached to the CR timing belt, PF roller axis. 
• The CR timing belt tension confirms whether or not it is normal. 
• Exchange the CR motor and ink tube. After the above part are exchanged, "CR motor Initialization" of maintenance mode 2 is run.
SERVICE CALL 00000102 :Waste ink box on the right side full
It is ’00,000,100’ and time in the detailed that displayed it to the LCD panel and be not fatal error
Not necessary ("Waste ink Initialization" of maintenance mode 2 is run.)
SERVICE CALL 00000103 : Waste ink box on the left side full
It is ’00,000,100’ and time in the detailed that displayed it to the LCD panel and be not fatal error.
Not necessary ("Waste ink Initialization" of maintenance mode 2 is run.)
SERVICE CALL 00010000: PF ENCODER CHECK ERROR
PF motor encoder check error The PF motor makes small revolutions clockwise and counter-clockwise. When it turns, the printer checks the rotary encoder (inside the motor) output signals to make sure the motor is turning at the correct speed/distance. If the encoder sends an incorrect signal, an error occurs.
Make sure there is nothing blocking the grid rollers. If that does not solve the problem, check the PF motor encoder connection. If there still is a problem, carry out the tension adjustment or phenol-formaldehyde motor exchange of the phenol-formaldehyde timing belt. If there is not a problem, carry out the following items. 
• Confirming whether the dirt and dust are not adhering to the PF loop scale and PF encoder. 
• The cable connector joint of the PF encoder and C362DRV board (CN8) are confirmed. 
• The PF timing belt tension confirmation/adjustment. In the case that there is not abnormality with above checking I gradually exchange the next part. 
• PF encoder 
• PF timing belt 
• PF loop scale 
• PF encoder extension cable 
• C362DRV board
SERVICE CALL 00010001: PF MOTOR STEP-OUT
PF motor out of step - the length of the PF motor internal encoder’s pulse is too long or too short compared to the regular pulse.
Make sure there is nothing blocking the grid rollers. If that does not solve the problem, check the PF motor encoder connection. If there still is a problem, try the following. • PF timing belt exchange 
• PF motor exchange 
• PF motor extension cable exchange 
• C362DRV board exchange.
SERVICE CALL 00010002: PF MOTOR OVER CURRENT
PF motor overcurrent - Feedback from the PF motor (IC35) driver’s 10-pin output (sensor signal) indicates that the PF motor’s current is irregular.
• The coil resistance value (6.7Ohm) the measurement of the PF motor. 
• PF motor extension cable exchange. 
• C362DRV board exchange.
SERVICE CALL 00010003: PF MOTOR IN POSITION TIME OUT
When be it locateds stable at the time of halt processing with the PF motor control, (the in position time) the position control inside period did not improve
• PF motor exchange 
• PF encoder exchange 
• PF timing belt exchange 
• C362DRV board exchange
SERVICE CALL 00010004: CR ENCODER CHECKING ERROR
CR motor encoder check error The CR motor makes small revolutions clockwise and counter-clockwise.When it turns, the printer checks the encoder output signals to make sure the motor is turning at the correct speed/distance. If the encoder doesn’t send the correct signal or output data, an error occurs.
It confirms whether there is not abnormal load etc. at the time of carriage migration and be abnormal no and do the checking of the CR encoder, in the case that the error is not canceled. In the case that there is abnormality : Carry out the tension of the steel belt adjustment or CR motor exchange. In the case that there is not abnormality : Confirm whether there are not dirt and damage in the CR encoder. The cable connector joint to the CR encoder and head Assy board CN15 are confirmed. Encoder pulse detection for T fence (scale 180a) of it comes off/whether or not there is not the contact with a CR encoder 
• Confirmation of the dirt/paper powder/damage of the confirmation T fence (scale 180a) the top 
• CR encoder exchange 
• CR motor exchange 
• C362DRV board exchange
SERVICE CALL 00010005: CR MOTOR STEP-OUT
The rotational speed of the CR motor abnormal. (it is long/short period at the time of prescription ).
It confirms whether there is not abnormal load etc. at the time of carriage migration and be abnormal no and do the checking of the CR encoder, in the case that the error is not canceled. In the case that there is abnormality: 
• Encoder pulse detection for T fence (scale 180a) of it comes off/whether or not there is not the contact with a CR encoder 
• Tension adjustment of the confirmation steel belt 
• Confirmation of the dirt / paper powder / damage of the T fence (scale 180a) the top 
• CR encoder exchange 
• CR motor exchange 
• C362DRV board exchange