ERAE ELT3220AP - 32 INCH LCD TV - TEST - ALIGNMENT PROCEDURE - FIRMWARE UPDATE
FUNCTION TEST & ALIGNMENT
ALL MODE RESET
- Press the “MENU” button and use ◀,▶button to move to “Setup” menu. Press ▼button to move to “Reset” and press “Enter” to select. Use ▲,▼ button to select “Yes” and press “Enter” button. The PDP TV will turn off then back on in few seconds. The parameters will be set to factory default.
PICTURE SETTING
- Press the “MENU” button and use ◄/► button to move to “Picture” menu.
- Press ▼button to move to “Custom adjust” and press “Enter” to select.
- Use ▲,▼button to the desired category to control and use ◄/►button to adjust the setting.
- Use ▲,▼ to select between Brightness, Contrast, Color, Tint, Sharpness.
SOUND SETTING
- Press the “MENU” button and use ◄/►button to move to “Sound” menu.
- Press ▼button to move to “Custom adjust” and press “Enter” to select.
- Use ▲,▼button to the desired category to control and use ◄/►button to adjust the setting.
- Use ▲,▼to select between Volume, Balance, Equalizer.
CHANNEL SETTING
- Press the “MENU” button and use ◄/► button to move to “Channel” menu.
- Press ▼ button to move to “Auto Search” and press “Enter” to select.
- Use ▲,▼button to move to “Start” and press “Enter “ to start the automatic channel search. All broadcasting channels will be set.
Adjusting PC Screen (Analog RGB)
- Press the “MENU” button and use ◄/► button to move to “Picture” menu.
- Press ▼button to move to “PC” and press “Enter” to select.
- Use ▲,▼ button to the desired category to control and use ◄/► button to adjust the setting.
- Use ▲,▼ to select between Auto Adjustment, Phase, H-Position, V-Position.
FIRMWARE UPDATE
Equipment Needed
# RS232 Cable
(P/N ) # PC (Personal computer) # Firmware Upgrade Program.
SETUP PROCEDURE
- Connect RS232 cable between RS232 connector of LCD TV and COM1 of PC
- Connect LCD TV Power.
- Find <FlashExpress.exe> program in the computer.
- Run < FlashExpress.exe > program.
- Click where mouse is located and find a directory, which <WARE3.INF> file is in. \
- And click “OK”
- Check if the port is COM1 and the protocol speed is 115200.
- Click “Flash” to upgrade program.