PANASONIC Curved TV - TX 65CZ952B OLED TV - HOW TO REMOVE PEDESTAL STAND AND BACK COVER
Back cover and Stand removal procedure - Pansonic TX65CZ952B - OLED TV
HANDLING THE OLED PANELAt least two people are required to move the OLED Panel.
Due to the large screen and thin design OLED Panel is weaker than other present TV set. If handle with both side OLED panel will be twisted and damaged. Transport only in upright position.
Transporting the OLED Panel facing upwards or downwards may cause damage to the
internal circuitry.
Handle the metal plate portion at top and bottom side of the panel. (Use handle hole of Back Cover when move the spare parts of OLED Panel.)
Handle the metal plate portion at top and bottom side of the panel. (Use handle hole of Back Cover when move the spare parts of OLED Panel.)
When laying the OLED panel
Handle the metal plate portion at top and bottom side of the panel.
Handle the metal plate portion at top and bottom side of the panel.
Due to the curved design (5000R) is introduced for
this OLED Panel if laying the OLED panel on the flat table directly OLED panel
will be twisted and damaged due to weight itself.
PEDESTAL ASSEMBLY REMOVAL
Prepare a CUSHION-FRONT (TPD0E51001) which included as one of packing for TV set or
spare part of OLED Panel on the flat surface.
Using CUSHION-FRONT is for safely service to avoid transformation or damage of OLED panel.
Using CUSHION-FRONT is for safely service to avoid transformation or damage of OLED panel.
Use handle hole of Back Cover and support at top of
the TV set in the area which can be handle and lay the front side of OLED TV to
prepared cushion front.
Remove the 8 fixing screws and pull out pedestal
assembly.
SCREWS (3)
XYN4+F14NK/8pcs
BACK COVER REMOVAL
Remove the 1 fixing screw and AC Cord cover.
Remove the 32 fixing screw and Back Cover.
SCREWS (1) THTD037J /1pcs
SCREWS
1 THTD037J /6pcs/
2 THEC1509 /18pcs/
3 XYN4+F14NK /8pcs/
1 THTD037J /6pcs/
2 THEC1509 /18pcs/
3 XYN4+F14NK /8pcs/