REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Tuesday, 5 March 2019

PANASONIC 3D HIGH DEFINITION VIDEO CAMERA - HDC-SDT750 - HDC-TMT750 - SERVICE MODE – ERROR CODE – FACTORY RESET - DISCHARGING THE FLASH CAPACITOR

PANASONIC 3D High Definition Video Camera - HDC-SDT750 - HDC-TMT750 - Service mode – Error code – Factory reset - Discharging the flash capacitor

Category: Digital Camera Repair and Service 

Contents of this article 

  • How to enter to service mode 
  • Factory reset procedure 
  • Flash capacitor discharging 

PANASONIC HDC-SDT750 - HDC-TMT750

How to Discharge the Capacitor on Flash P.C.B.
CAUTION:
1. Be sure to discharge the capacitor on FLASH P.C.B..
2. Be careful of the high voltage circuit on FLASH P.C.B. when servicing.
Discharging Procedure
1. Refer to the disassemble procedure and Remove the necessary parts/unit.
2. Put the insulation tube onto the lead part of Resistor (ERG5SJ102:1kΩ /5W).
(an equivalent type of resistor may be used.)
3. Put the resistor between both terminals of capacitor on FLASH P.C.B. for approx. 5 seconds.
4. After discharging confirm that the capacitor voltage is lower than 10V using a voltmeter.

How to Replace the Lithium Battery
Replacement Procedure
1. Remove the MIC AMP P.C.B.. (Refer to Disassembly Procedures.)
2. Remove the Lithium battery (Ref. No. “B6401” at component side of MIC AMP P.C.B.) and then replace it into new one.

NOTE:
This Lithium battery is a critical component.
(Type No.: ML-614S/ZTK )
It must never be subjected to excessive heat or discharge.
It must therefore only be fitted in requirement designed specifically for its use.
Replacement batteries must be of same type and manufacture.
They must be fitted in the same manner and location as the original battery, with the correct polarity contacts observed.
Do not attempt to re-charge the old battery or re-use it for any other purpose.
It should be disposed of in waste products destined for burial rather than incineration.
How to Define the Model Suffix (NTSC or PAL model)
There are seven kinds of HDC-SDT750/TMT750.
a) HDC-SDT750PP
b) HDC-SDT750EB/EF/EG/EP
c) HDC-SDT750EE
d) HDC-TMT750GT
e) HDC-TMT750GK
f) HDC-TMT750GD
g) HDC-SDT750GC, TMT750GC
What is the difference is that the “INITIAL SETTING” data which is stored in Flash ROM mounted on Main P.C.B..
NOTE:
After replacing the MAIN P.C.B., be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-AVC” web-site in
“TSN system”, together with Maintenance software.
Service Mode
1. Indication method of the service menu
Set the mode dial “Motion Picture Recording” mode.
2. Turn the power on, and then while keep pressing the “Zoom lever” to W side, “Intelligent auto/Manual” button and “Menu” button for more than 3 seconds until the top screen of the Service Mode Menu being displayed
Service mode menu
Screen display
Contents
Function
1

Factory settings

Function to throw a product up in a factory shipment state
(When recorded data in Built-in memory, “error display” is done)
3

Built-in memory self check execution
(HDC-TMT750 only)

Function to check self as for the state of Built-in memory

4


Lock search history indication


Display the camera system error cord for three histories saved
in EEPROM

5

Power ON self check result display

Power ON self check (function to diagnose correct function of
the device and interface between devices) result display
NOTE:
Do not using service mode except above table of Service mode menu.
3. End method of the top screen of the service mode menu
Push the “Menu” button to end the service mode, and then POWER OFF.
Built-in Memory Self Check Execution (HDC-TMT750 only)
Touch the [ 3 ] of LCD, select Built-in memory self check execution.
Indication contents
# Built-in memory self check result display
Display the Built-in memory self check execution.
Displays other than “OK” are abnormalities of Built-in memory.
Push the “Menu” button to end the service mode, and then POWER OFF.
Lock Search History Indication
Touch the [ 4 ] of LCD, select Lock search history indication.
Indication contents
# Lock search history indication
Display the camera system error cord for three histories saved in EEPROM.
# The error cord contents which are displayed
Error code
Function
51
Focus control is abnormal
52
Zoom control is abnormal
53
OIS lens control is abnormal
71
Lens cover open/close is abnormal
72
Cooling fan is abnormal
73
High temperature is abnormal
33
Communication between camera to ARM is abnormal
Push the “Menu” button to end the service mode, and then POWER OFF.
Power ON Self Check Result Display
Touch the [ 5 ] of LCD, select Power ON self check result display.
Indication contents
# Power ON self check result display
Function to diagnose correct function of the device and interface between devices result display.
Display the following commnucation test result.
- CAM-PWR : Commnucation test between IC2006 to IC301
- CAM-UNI : Commnucation test between IC3401 to IC301
Display other than “OK” are abnomalities of each lines.
Cutting of battery connection or AC power supply connection to end the service mode.
CAUTION  (When servicing FLASH P.C.B.)
1. Be sure to discharge the capacitor on FLASH P.C.B..
Refer to “HOW TO DISCHARGE THE CAPACITOR ON FLASH P.C.B.”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH P.C.B..
3. DO NOT allow other parts to touch the high voltage circuit on FLASH P.C.B.
Factory Setting
PROCEDURE
1. Set the mode dial “Motion Picture Recording” mode.
2. Turn the power on, and then while keep pressing the “Zoom lever” to W side, “Intelligent auto/Manual” button and “Menu” button for more than 3 seconds until the top screen of the Service Mode Menu being displayed.
3. Touch the [ 1 ] of LCD.
4. Touch the [ YES ] of LCD.
5. After few seconds “END” is displayed on LCD monitor. Cutting of battery connection or AC power supply connection as a
completion of the “FACTORY SETTINGS”.
The factory settings clean up and/or refresh the following settings.
1. MENU, MODE, ADJUSTMENT VALUE.
2. SD card format.
3. Reset the folder number and file number of still pictures.
(Setting the folder number is 100, and file number is 0.)
4. Clear the mechanism lock information.
5. Clear the service mode information contents.
6. Close the lens cover
7. Initialize the VIERA Link Physical Address.
8. Confirm the data of Built-in memory is cleared. (only HDC-TMT750)