REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Wednesday, 6 March 2019

PANASONIC HC-X800 HD VIDEO CAMERA SERVICE MODE – FACTORY RESET – ERROR CODES – DIGITAL CAMERA SERVICE AND REPAIR

PANASONIC HC-X800 HD Video Camera Service mode – factory reset – Error codes – Digital Camera service and repair

                                                Category: Digital Camera Repair and service  

Contents of this article 
  • How to access Service mode
  • Factory reset
  • Error codes 


PANASONIC HC-X800

Service Mode
1. Indication method of the service menu
Set the mode switch "Motion Picture Recording" mode.
2.
While the power is turned OFF, keep pressing the "POWER" button, "Zoom lever" to W side and "iA/Manual" button for more than 3 seconds until the top screen of the Service Mode Menu being displayed.
Service mode menu
Screen display
Contents
Function
1
Factory settings
Function to throw a product up in a factory shipment state
4
Lock search history indication
Display the camera system error cord for three histories saved in EEPROM
5


Power ON self check result display


Power ON self check (function to diagnose correct function of
the device and interface between devices) result display

9

Forced full flash emission

Forced full flash emission for discharging the capacitor on
FLASH P.C.B. and set to prohibit charge
10

Erasing the lock histories


Erasing the error histories (working time is not erased)

12

Camera data indications while the video playback

Display the camera informations (Shutter speed, Iris value,
White balance and focal length) while playing recorded video
NOTE:
Do not using service mode except above table of Service mode menu.
3. End method of the top screen of the service mode menu
Touch the [ EXIT ] of LCD to end the service mode, and then POWER OFF.
Lock Search History Indication
Touch the [ 4 ] of LCD, select Lock search history indication.
Indication contents
# Lock search history indication
Display the camera system error cord for three histories saved in EEPROM.
# The error cord contents which are displayed
Error
code Function
51
Focus control is abnormal
52
Zoom control is abnormal
53
OIS lens control is abnormal
71
Lens cover open/close is abnormal
72
Cooling fan is abnormal
73
High temperature is abnormal

Touch the [BAK] of LCD to end the service mode, and then POWER OFF.
Power ON Self Check Result Display
Touch the [ 5 ] of LCD, select Power ON self check result display.
Indication contents
# Power ON self check result display
Function to diagnose correct function of the device and interface between devices result display.
Display the following communication test result.
-CAM-PWR : Communication test between IC3401 to IC2304
-CAM-UNI : IC3401 internal communication test.
Display other than "OK" are abnormalities of each lines.
Cutting of battery connection or AC power supply connection to end the service mode.
Forced full flash emission
Touch the [ 9 ] of LCD, select Forced full flash execution.
Indication contents
# Discharging the capacitor without using register.
Forced full flash emission for charge capacitor completely discharge.
To prevent electric shock, we recommend enforcement before disassembling. Cutting of battery connection or AC power supply connection to end the service mode.
Erasing the lock histories
Touch the [ 10 ] of LCD, select erasing the lock histories execution.
Indication contents
# Erasing the error histories stored in EEPROM. (working time is not erased)
Cutting of battery connection or AC power supply connection to end the service mode. Camera data indications while the video playback
Touch the [ 12 ] of LCD, select indicating the camera informations while playing back the recorded video.
Indication contents
# While playing back the recorded videos, the camera informations (Shutter speed, Iris value, White balance and focal length) are superimposed on the LCD screen. Press the power button and turn off.
Factory reset
How To Turn On The Factory Settings?
1. Set the mode switch "Motion Picture Recording" mode.
2. While the power is turned OFF, keep pressing the "POWER" button, "Zoom lever" to W side and "iA/Manual" button for more than 3 seconds until the top screen of the Service Mode Menu being displayed.
3. Touch the [ 1 ] of LCD.
4. Touch the [ YES ] of LCD.
5. After few seconds "END" is displayed on LCD monitor. Cutting of battery connection or AC power supply connection as a completion of the "FACTORY SETTINGS".
The Factory Settings Description
The factory settings clean up and/or refresh the following settings.
1. MENU, MODE, ADJUSTMENT VALUE.
2. SD card format.
3. Reset the folder number and file number of still pictures.
(Setting the folder number is 100, and file number is 0.)
4. Clear the mechanism lock information.
5. Clear the service mode information contents.
6. Clear the setting date.
7. Close the lens cover.
8. Initialize the VIERA Link Physical Address.
9. Rewriting lock setup of destination information.