REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Wednesday 27 March 2019

PANASONIC - TY-TP42P10S _ TY-TP50P10S -TOUCH PANEL _ TO REWRITE DATA WHEN REPLACING MOTHER BOARD.

PANASONIC - TY-TP42P10S _ TY-TP50P10S -TOUCH PANEL _ TO REWRITE DATA WHEN REPLACING MOTHER BOARD.




RE-WRITE DATA 

  • Adjusted data is saved respectively in EEPROM inside the Main Board.
  • Start "LtabMonA" with Touch Panel connected.
  • Press "Parameter" after start "LtabMonA".
Parameter display appears. (The data of the Main Board currently connected is shown.)
Press "Save File" button and save as "Name". (extension.prm)
The data write on the new Board.
  1. Press "Load file" and specify the data saved as above. (extension. prm)
  2. The data which was read is displayed.
  3. After that, press "Write to ROM" and the data is written.  (Unless you push the button, the data cannot be written.
  4. Press "OK" to close "Parameter" display.
  5. After writing the data, finish "LtabmonA" once.
  6. The written data is enabled by removing and inserting the USB cable.
  7. The basic operation for replacing the Main Board finishes here. Confirm the contents to be checked after adjustment.
  8. Some components come to the end of life and may not be recovered to the shipping condition.
  9. If the check contents cannot be satisfied, adjust the items. If it still cannot be recovered after adjusting all items, changing the Sensor Boards is necessary.

ADJUST THE OPTICAL AXIS
Purpose for adjustment : Adjusting so that L and R sensors can receive the reflected light properly from the reflecting plate.
  • Start "LtabMonA" with Touch Panel connected.
  • After starting "LtabmonA". the sensor wave pattern appears. Add check mark for "Continuous" and "2D image".
  • Display "Parameter" and select view "Camera Scope" tab.
  • Press "L Search". It will take time to search for the optical axis.
  • When the wave shape is swollen, press "Auto set". The wave shape is more swollen and then L optical axis adjustment is complete.
  • Press "R Search". It will take time to search for the optical axis.
  • When the wave shape is swollen, press "Auto set". The wave shape is more swollen and then R optical axis adjustment is complete.

  • Press " Write to ROM " to save the adjusted data which was completed. "Writing parameter" display appears.  Press "OK" 
  • Writing (Saving) the adjusted data is complete by pressing "OK".
  • Press "Initialize"
  • Both red and blue wave shapes match with each other. The red wave shape is set during start-up and initialization with basic light level. The blue wave shape shows the operation in progress.
  • Adjustment from here can be made with this wave shape condition.