SANYO DP37649 service mode and adjustment
SANYO DP37649
ON-SCREEN SERVICE MENU SYSTEM
1. Enter the Service Menu:
# Turn off the receiver and disconnect the AC power supply.
# While pressing the Volume (–) button on the television, reconnect the AC power supply. The Service Menu will now appear. The remote can now be used to make adjustments
1. Enter the Service Menu:
# Turn off the receiver and disconnect the AC power supply.
# While pressing the Volume (–) button on the television, reconnect the AC power supply. The Service Menu will now appear. The remote can now be used to make adjustments
2. Service Adjustments:
# Press the Cursor UP and DOWN key to select the desired service menu item you want to adjust. See page 4 for the On-screen Service Menu.
# Use the Cursor or key to adjust the data. The or key will increase or decrease the data sequentially.
3. Exit from the Service Menu:
# Press the MENU key to turn off the Service Menu display
# Press the Cursor UP and DOWN key to select the desired service menu item you want to adjust. See page 4 for the On-screen Service Menu.
# Use the Cursor or key to adjust the data. The or key will increase or decrease the data sequentially.
3. Exit from the Service Menu:
# Press the MENU key to turn off the Service Menu display
PROGRAM CODES
The microprocessor used in this model is a multi-purpose type and is used in several different models. To ensure proper operation and the correct features for your particular model, the program codes must be correct.
Note 1. Option Data 1 (NO. 087 OP1) should be hexadecimal 00. See 087 above. If this program code is wrong the TV will not operate properly.
The microprocessor used in this model is a multi-purpose type and is used in several different models. To ensure proper operation and the correct features for your particular model, the program codes must be correct.
Note 1. Option Data 1 (NO. 087 OP1) should be hexadecimal 00. See 087 above. If this program code is wrong the TV will not operate properly.
Note 2. Option Data 2 (NO. 088
OP2) should be hexadecimal 21. See 088 above.
If this program code is wrong the TV will not operate properly.
CPU (IC800) is programmed so the set will go
to standby mode when there is circuit failure as described below. (Refer to“Block
Diagram Power Lines”.) This unit is equipped with a Power Failure Detector
function included in the CPU which checks for an abnormal condition in the
chassis power supplies. If, while the power is on, a failure is caused by any
of the following that results in a low voltage supply, the CPU will turn the
unit off in 1.5 seconds to prevent further damage:
# Failure within the power supply circuits.
# A short circuit in the load side from the supply. Power Failure: Detected voltage failure for circuit. (Connected to IC800 pin 48 and pin 23.) (Normal: High; Failure: Low)
If, while the power is off, the power is switched on and any of these failures remains uncorrected, the CPU will shut off the power within three seconds.
# Failure within the power supply circuits.
# A short circuit in the load side from the supply. Power Failure: Detected voltage failure for circuit. (Connected to IC800 pin 48 and pin 23.) (Normal: High; Failure: Low)
If, while the power is off, the power is switched on and any of these failures remains uncorrected, the CPU will shut off the power within three seconds.
Check the
following if the unit is turned off by the power failure detector.
1. Disconnect the AC power cord (120V AC line) for a short time.
2. Connect a DC Voltmeter to the circuits shown below.
3. Press the Power key and check for the proper voltage supplies.
4. If any of these voltages is low, the power failure detector should turn the unit off within three seconds.
5. Check all circuits shown below.
Note: If power failure is detected 3 times in 15 minutes, the set will enter the standby mode and cannot be switched On.To reset the operating programs of the CPU it is necessary to disconnect the AC cord for a short time.
CLICK ON THE IMAGE TO ZOOM IN
1. Disconnect the AC power cord (120V AC line) for a short time.
2. Connect a DC Voltmeter to the circuits shown below.
3. Press the Power key and check for the proper voltage supplies.
4. If any of these voltages is low, the power failure detector should turn the unit off within three seconds.
5. Check all circuits shown below.
Note: If power failure is detected 3 times in 15 minutes, the set will enter the standby mode and cannot be switched On.To reset the operating programs of the CPU it is necessary to disconnect the AC cord for a short time.