REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Saturday, 9 March 2019

SHARP LC-30HV6U SERVICE MODE AND POWER SUPPLY CIRCUIT

SHARP LC-30HV6U SERVICE MODE AND POWER SUPPLY CIRCUIT


SHARP LC-30HV6

SERVICE MODE AND POWER SUPPLY CIRCUIT 


ADJUSTMENT
The adjustment values are set to the optimum conditions at the factory before shipping. If a value should become improper or an adjustment is required due to part replacement, make an adjustment according to the following
procedure.
Preparation
Note that the unit should be replaced when the receiver IC (IC2206), CONFIG ROM (IC2202) or microprocessor (IC2004) is replaced.
Applicable unit: DKEYHC094FE51
Adjusting procedure
# VLS BIAS (15V) voltage adjustment
# Entering the adjustment process mode  > COM BIAS adjustment > Background adjustment
How to enter the adjustment process mode
(1) When the AVC center is not connected
# Turn OFF the monitor main power. Turning ON the monitor main power while pressing the "INPUT" key and "VOL (–)" key on the top face of the monitor main body together will establish the "Monitor Process" mode.
(2) When the AVC center is connected
# Turn OFF the monitor main power. Turning ON the monitor main power while pressing the "CH (Ù)" key and "VOL (+)" key on the top face of the monitor main body together will establish "Monitor Process" mode.
In each case of (1) and (2), "<K>" is displayed in the upper left portion of the screen.
Then, pressing any key will bring you to the first page of the "Monitor Adjustment" mode
Adjustment
VLS BIAS (13V) voltage adjustment (R4231)
Connect a digital volt meter to TL4122 (or C4180+) on the LCD Control PWB and make a adjustment with the R4231 so that the voltage becomes 13.00V±0.05V.
COM BIAS adjustment
Shift to the "COM BIAS" item with the cursor UP/DOWN key and select a numeric value with the cursor RIGHT/LEFT key. Changing the numeric value with the cursor UP/DOWN key will make appear the test pattern. Make an adjustment so that the flicker near the center of the screen is minimized.
Background adjustment
Start up the set with the AVC System connected and adjust the background of the monitor.
# Procedure
-1) Display the adjustment screen (200-level gray scale on High side, 48-level gray scale on Low side).
-2) Adjust "R OFFSET", "G OFFSET" and "B OFFSET" so that the 200-level gray scale pattern becomes normative. Adjust the chromaticity of the High pattern (in the left portion of the screen) so that x = 0.290 and y = 0.299.
-3) Adjust "R GAMMA", "G GAMMA" and "B GAMMA" so that the 48-level gray scale pattern becomes normative.
Adjust the chromaticity of the Low pattern (in the right portion of the screen) so that x = 0.276 and y = 0.278.
The above-mentioned adjustments can be made according to the following procedure.
Adjusting method using RS-232C
# Get a personal computer with a COM port (RS-232C) equipped with WINDOWS 95/98/me/2000/xp and a RS-232C crossing cable
# Start up the set with the RS-232C cable connected.
# Start up the terminal software.
(Freeware products available on the Internet can be used.)
# Make setting as shown below.
Baud rate : 9600
Data : 8 bits
Parity : None
Stop : 1 bit
Flow control : None
# If the above setting is made correctly, pressing the "SET/ENTER" key on the PC will make "ERR" appear on the terminal software.
# In this state, entering a command shown in the table bellow and pressing the "SET/ENTER" key will allow you to make an adjustment.
If "OK" is displayed on the terminal software after the "SET/ENTER" key is pressed, the command has been entered successfully.
If "ERR" is displayed, enter the command again
Lamp error detection
1. Feature description
This liquid-crystal color TV incorporates a lamp error detection feature (lamp error detection) that automatically turns OFF the power for safety under abnormal lamp or lamp circuit conditions. If anything is wrong with the lamp or lamp circuit or the lamp error detection feature is activated for some reason, the following will result.
1. The power of TV main body is turned OFF about 13 seconds after it is turned ON. (The power LED on the front of the TV turns red from green and keeps blinking in red (ON for 250ms and OFF for 1sec).)
2. If 1 occurs five times consecutively, it becomes impossible to turn ON the power. (The power LED keeps blinking in red (ON for 250ms and OFF for 1sec).)
Measures
1.Checking with lamp error detection OFF
Disconnect the cable connected to the AVC System Turn OFF the monitor main power. Turning ON the monitor main power while pressing the "INPUT" key and "VOL (–)" key together will establish the "Monitor Process" mode ("<K>" is displayed).
Then, pressing any key will bring you to the first page of the "Monitor Process" mode. This allow you to check the lamp and lamp circuit for abnormal conditions. Check that "L ERR RESET" on the fourth line of the first page of the "Monitor Process" mode is 1 or more. If it is 1 or more, a lamp error has been detected.
2.Reset of lamp error count
After checking the lamp and lamp circuit for abnormal conditions, reset the lamp error count. Move the arrow to "L ERR RESET" on the fourth line of the first page of the "Monitor Process" mode with the cursor UP/DOWN key and select the numeric value of "L ERR RESET" with the cursor RIGHT/LEFT key. In this state, press the cursor UP/DOWN key to reset it to "0".
Table of monitor power LED blinking timing at the time of error occurrence
LED BLINKING
Error type

1


Cable error
AVC-side power error
Blinking once: Slow

1

Lamp error
Blinking once: Fast
2

Monitor power error
Blinking twice

3


AVC temperature
error
Blinking three times
4

AVC fan error
Blinking four times

5


Monitor temperature
error
Blinking five times

6  

Monitor fan error
Blinking six times

7

Monitor 1-bit error
Blinking seven times


 POWER SUPPLY CIRCUIT 