SHARP LC-52LE640U - LC-60LE640U - LC-70LE640U - LC-80LE633U SERVICE MODE SOFTWARE UPDATE AND ERROR CODES
SHARP LC-52LE640U - LC-60LE640U - LC-70LE640U - LC-80LE633U
SERVICE MODE SOFTWARE UPDATE AND ERROR CODES
ADJUSTMENT PROCEDURE
The adjustment values are set to the optimum conditions at the factory before shipping. If a value should become improper or an adjustment is required due to part replacement, make an adjustment according to the following procedure.
After replacement of any PWB unit and/or IC for repair, please note the following.
# When replacing the following units, make sure to prepare the new units loaded with updated software.
# When replacing the LCD control PWB, perform the VCOM adjustment.
Upgrading of each microprocessor software
CAUTION: Never “POWER OFF” the unit when software upgrade is ongoing. Otherwise the system may be damaged beyond recovery.
Software version upgrade
The model employs the following software.
# Main software (please use a software version after OKLA_LE857_xxx.USB).
# Monitor microprocessor software (please use a software version after OKLAMxxx.SMB.)
The main software, monitor microprocessor software can be upgraded by using a general-purpose USB Memory.
The followings are the procedures for upgrading, explained separately for the main software, monitor microprocessor software.
Main software version upgrade
Get ready before you start
# USB Memory of 128MB or higher capacity.
# PC running on Windows 98/98SE/ME/2000/XP operating system.
# USB Memory reader/writer or PC with a USB port.
# The file system of a USB memory is FAT. (FAT32 supports)
# Use the USB memory without other functions. (lock and memory reader...etc)
Preparations
To upgrade the main software, it is necessary to get ready the USB Memory for version upgrade before you start. Follow the steps below and create the USB Memory for version upgrade.
1. Copy the file OKLA_LE857_xxx.USB for version upgrade to the root directory (folder) of the USB Memory.
NOTE: In the USB Memory drive, do not store other folders or unrelated files, or more than one file for version upgrade. Now the USB Memory for version upgrade is ready.
The adjustment values are set to the optimum conditions at the factory before shipping. If a value should become improper or an adjustment is required due to part replacement, make an adjustment according to the following procedure.
After replacement of any PWB unit and/or IC for repair, please note the following.
# When replacing the following units, make sure to prepare the new units loaded with updated software.
# When replacing the LCD control PWB, perform the VCOM adjustment.
Upgrading of each microprocessor software
CAUTION: Never “POWER OFF” the unit when software upgrade is ongoing. Otherwise the system may be damaged beyond recovery.
Software version upgrade
The model employs the following software.
# Main software (please use a software version after OKLA_LE857_xxx.USB).
# Monitor microprocessor software (please use a software version after OKLAMxxx.SMB.)
The main software, monitor microprocessor software can be upgraded by using a general-purpose USB Memory.
The followings are the procedures for upgrading, explained separately for the main software, monitor microprocessor software.
Main software version upgrade
Get ready before you start
# USB Memory of 128MB or higher capacity.
# PC running on Windows 98/98SE/ME/2000/XP operating system.
# USB Memory reader/writer or PC with a USB port.
# The file system of a USB memory is FAT. (FAT32 supports)
# Use the USB memory without other functions. (lock and memory reader...etc)
Preparations
To upgrade the main software, it is necessary to get ready the USB Memory for version upgrade before you start. Follow the steps below and create the USB Memory for version upgrade.
1. Copy the file OKLA_LE857_xxx.USB for version upgrade to the root directory (folder) of the USB Memory.
NOTE: In the USB Memory drive, do not store other folders or unrelated files, or more than one file for version upgrade. Now the USB Memory for version upgrade is ready.
How to upgrade the software
1. Unplug the AC cord.
2. Insert the USB Memory for version upgrade into the service socket.
3. Plug in the AC cord with power button pressed down.
4. After 5 seconds, unpress the power button.
5. After the unit startup, the system upgrade screen as shown below within 20-40 second
1. Unplug the AC cord.
2. Insert the USB Memory for version upgrade into the service socket.
3. Plug in the AC cord with power button pressed down.
4. After 5 seconds, unpress the power button.
5. After the unit startup, the system upgrade screen as shown below within 20-40 second
6. Even a single failure in the process will
trigger the upgrade failure screen.
NOTE: In the event of a failure, repeat
the upgrade process. If the process repeatedly fails, it is likely that the
hardware need fixing.
7. Upon completion of the whole process, the upgrade success screen as shown below appears. You can check the new software version on this screen. The version information appears after the upgrade is complete.
7. Upon completion of the whole process, the upgrade success screen as shown below appears. You can check the new software version on this screen. The version information appears after the upgrade is complete.
8. Unplug the AC cord and remove the USB Memory
for version upgrade.
9. Now the software version upgrade is complete.
NOTE: When you are done with the software version upgrade, start the set, go to the top page of the adjustment process screen and check the main software version information.
9. Now the software version upgrade is complete.
NOTE: When you are done with the software version upgrade, start the set, go to the top page of the adjustment process screen and check the main software version information.
Monitor microprocessor software
version upgrade
Create the USB memory for monitor microprocessor software version upgrade in the same manner as explained in the “Main software version upgrade”.
Copy the file OKLA_LE857_xxx.USB and OKLAMxxx.SMB. (named temporarily) for monitor microprocessor software version upgrade to the USB memory.
How to upgrade the software
1. Unplug the AC cord.
2. Insert the USB Memory for version upgrade into the service socket.
3. Plug in the AC cord with power button pressed down.
4. After 5 seconds, unpress the power button.
CAUTION: # The moment this operation is done, the upgrading of the monitor microprocessor software starts. While the upgrade is ongoing, never power off the unit. Otherwise the upgrade will fail and the system may be serious damaged beyond recovery (inability to start).
# After the monitor microprocessor software is upgraded, also perform the ‘Industry Init’.
5. After the unit startup, the upgrade starts. The power led will blink continuously. Also, an upgrade screen will be shown during a minor upgrade.
Create the USB memory for monitor microprocessor software version upgrade in the same manner as explained in the “Main software version upgrade”.
Copy the file OKLA_LE857_xxx.USB and OKLAMxxx.SMB. (named temporarily) for monitor microprocessor software version upgrade to the USB memory.
How to upgrade the software
1. Unplug the AC cord.
2. Insert the USB Memory for version upgrade into the service socket.
3. Plug in the AC cord with power button pressed down.
4. After 5 seconds, unpress the power button.
CAUTION: # The moment this operation is done, the upgrading of the monitor microprocessor software starts. While the upgrade is ongoing, never power off the unit. Otherwise the upgrade will fail and the system may be serious damaged beyond recovery (inability to start).
# After the monitor microprocessor software is upgraded, also perform the ‘Industry Init’.
5. After the unit startup, the upgrade starts. The power led will blink continuously. Also, an upgrade screen will be shown during a minor upgrade.
6. If the upgrade fails, power led will stop
blinking. Also, the upgrade failure screen will be shown if upgrade screen
NOTE: In the event of a transient
failure, upgrade will be automatically retried up to three times. If the
process repeatedly fails, hardware may be the cause.
7. The upgrade success screen will be shown if upgrade screen.
7. The upgrade success screen will be shown if upgrade screen.
8. Unplug the AC cord and remove the USB Memory
for version upgrade.
9. Now the software version upgrade is complete.
NOTE: When you are done with the software version upgrade, start the set, go to the top page of the adjustment process screen and check the monitor microprocessor software version information and panel size information.
9. Now the software version upgrade is complete.
NOTE: When you are done with the software version upgrade, start the set, go to the top page of the adjustment process screen and check the monitor microprocessor software version information and panel size information.
Entering and exiting the adjustment
process mode
1) Before entering the adjustment process mode, the AV position RESET in the video adjustment menu.
2) While holding down the “VOL (–)” and “INPUT” keys at a time, plug in the AC cord of the main unit to turn on the power.
The letter “<K>” appears on the screen.
3) Next, hold down the “VOL (–)” and “CH ( DOWN )” keys at a time.
(The “VOL (–)” and “CH ( DOWN )” keys should be pressed and held until the display appears.)
Multiple lines of blue characters appearing on the display indicate that the unit is now in the adjustment process mode. When you fail to enter the adjustment process mode (the display is the same as normal startup), retry the procedure.
4) To exit the adjustment process mode after the adjustment is done, unplug the AC cord from the outlet to make a forced shutdown. (When the power was turned off with the remote controller, once unplug the AC cord and plug it again. In this case, wait 10 seconds or so before plugging.)
CAUTION: Use due care in handling the information described here lest your users should know how to enter the adjustment process mode. If the settings are tampered in this mode, unrecoverable system damage may result.
1) Before entering the adjustment process mode, the AV position RESET in the video adjustment menu.
2) While holding down the “VOL (–)” and “INPUT” keys at a time, plug in the AC cord of the main unit to turn on the power.
The letter “<K>” appears on the screen.
3) Next, hold down the “VOL (–)” and “CH ( DOWN )” keys at a time.
(The “VOL (–)” and “CH ( DOWN )” keys should be pressed and held until the display appears.)
Multiple lines of blue characters appearing on the display indicate that the unit is now in the adjustment process mode. When you fail to enter the adjustment process mode (the display is the same as normal startup), retry the procedure.
4) To exit the adjustment process mode after the adjustment is done, unplug the AC cord from the outlet to make a forced shutdown. (When the power was turned off with the remote controller, once unplug the AC cord and plug it again. In this case, wait 10 seconds or so before plugging.)
CAUTION: Use due care in handling the information described here lest your users should know how to enter the adjustment process mode. If the settings are tampered in this mode, unrecoverable system damage may result.
ERROR CODES
Display
|
Error
description
|
02
|
Initial
communication from the main CPU is not received.
|
03
|
Only
the initial communication is received.
|
04
|
Until
panel information request reception
|
05
|
Until
initialization completion reception
|
06
|
Until
version notification transmission
|
07
|
Until
start-up information notification transmission
|
08
|
Until
start-up information response reception
|
09
|
Until
time-out setting reception
|
0A
|
Request
time-out
|
0B
|
Restart
time-out during the beginning of time acquisition start-up
|
0C
|
Ending
sequence time-out
|
0D
|
Preset
start-up time-out during completion
|
0E
|
Download,
start-up time-out
|
0F
|
Time
acquisition time-out
|
11
|
Regular
communication time-out
|
16
|
Backlight
error
|
1A
|
Monitor
temperature failure
|
1E
|
DET_13V
failure
|
1F
|
DET_D3V3
failure
|
21
|
DET_PNLxxV
failure
|
23
|
Error
standby request from the main CPU
|
Factory Resetting
# Point the cursor to [INDUSTRY INIT (+Cause)],
set to “ON” using [+]/[-] of the [VOL] key, and press the [ENT] key. The
version confirmation screen appears on the green screen. It is completed when [SUCCESS]
is displayed at the top. (If error occurs, [ERROR] is displayed on the red
screen.)
# Turn off the AC power.
# Turn off the AC power.
The following items are initialized when
configuring the factory setting.
1) User set value
2) Channel data (broadcasting frequency, etc.)
3) Password setting value
4) Operating time
5) Standby Cause
6) Auto installation flag
7) V-CHIP block setting value
1) User set value
2) Channel data (broadcasting frequency, etc.)
3) Password setting value
4) Operating time
5) Standby Cause
6) Auto installation flag
7) V-CHIP block setting value