SONY 50SX100U LCD PROJECTION TV - ERROR CODES - LED BLINKING CODES
SONY KF-50SX100-
KF50SX100K - KF/50SX100U LCD PROJECTION TV
SELF DIAGNOSTIC – BLINKING CODES –
ERROR CODES
SPECS:
TV System B / G / H,D / K,I,L
Colour System
PAL, SECAM \NTSC3.58, 4.43 (Video IN only)
Channel Coverage
VHF > E2 ~ E12
UHF > E21~E69
CATV >S1~S20
HYPER > S21~S41
D /K > R-1~R12, R11~R69
I > UHF B21~B69
L > F2~F10, B-Q, F21~F69
The identification of errors is triggered in one of two ways.
1) Busy or
2) Device failure to respond to IIC. In the event of one of
these situations arising the software will first try to release the bus if busy
(Failure to do so will report with continuous flashing LED) and then
communicate with each device in turn to establish if a device is faulty. If a
device is found to be faulty the relevant device number will be displayed
through the LED (Series of flashes which must be counted) , non fatal errors
are reported using this method.
BLINKING CODES
ERROR DETECTION MONITOR
Device acknowledges is used to check IIC errors. Each device is checked three times, if there
is no acknowledge after every attempt, it will be regarded as an error. There are three step to check errors.
IIC line 0: If all
devices except the NVM have errors, IIC line 0 errors are displayed.
Each device check: if IIC line error and board error are not detected then the device with an error is displayed.
Each device check: if IIC line error and board error are not detected then the device with an error is displayed.
The detected errors can be displayed as follows:
1) Error Monitor Menu
2) Error Reader
1) Error Monitor Menu
2) Error Reader
Error Monitor Menu
The error monitor menu is displayed by selecting Service mode : Monitoring. The following menu will be displayed.
The error monitor menu is displayed by selecting Service mode : Monitoring. The following menu will be displayed.
Error Reader Display
The error reader display is connected to the service connector to read actual error codes. The part number for the error reader display is S-188-900-10. Once an error has been detected it will then be displayed on the two digit error reader. The errors displayed refer to the following table
The error reader display is connected to the service connector to read actual error codes. The part number for the error reader display is S-188-900-10. Once an error has been detected it will then be displayed on the two digit error reader. The errors displayed refer to the following table