REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Monday 25 March 2019

SONY HCD-AZ2D _ HCD-AZ5D _ DVD SERVICE MODE _ MIRROR TIME ADJUST_ RAM CLEAR

SONY HCD-AZ2D _  HCD-AZ5D _  DVD SERVICE MODE _  MIRROR TIME ADJUST_ RAM CLEAR







  • DVD Mechanism Type:  CDM86-DVBU101
  • Optical Pick-up Block Name:  KHM-310CAB
  • Tape Transport Mechanism Type [A]:  CMAL5Z230
  • Tape Transport Mechanism Type [B]:  CMAL1Z254A

TO START DVD SERVICE MODE

  • Press the [POWER] button to turn the power on.
  • Touch the [DVD] sensor to select the “DVD”.
  • Press the [EJECT] button and touch two sensors of [STOP] , [VOLUME+] simultaneously.
  • The message “SERVICE IN” will be displayed on the fluorescent indicator tube and the Rimocon Diagnosis Menu is displayed on the on-screen display on the monitor TV as follows.
  • The model name, IF-con version and Syscon version is displayed at the bottom of the on-screen display.

Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. Video Level Adjustment
Model Name :AZXD_XX
IF-con :Ver.xx.xx (xxxx)
Syscon :Ver.x.xxx
  • To execute each function, press its number by using numeric button on the remote commander (RM-AMU001)
  • To release from this mode, press the [POWER] button to turn the power off.
DRIVE MANUAL OPERATION
  • The Drive Manual Operation menu consists of five main functions.
  • On the Remocon Diagnosis Menu screen, press [2] button on the remote commander, and the following Drive Manual Operation menu will be displayed.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time Adjust
0. Return to Top Menu

MIRROR TIME ADJUST
  • On the Drive Manual Operation menu screen, press [5] button on the remote commander, and the following MIRR time Adjust Menu will be displayed.

MIRR time Adjust Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:
3. Threshold:
4. Save to EEPROM
5. Default set MIRR time
[Open] Tray open [Close] tray close
[0] Return to previous menu
There are five main commands in the Mirr time Adjust menu. The functions of each command are described in the following page.
  1. CD MIRR time Check:  This command checks the Mirror time value for CD disc.
  2. DVD MIRR time Check:  This command checks the Mirror time value for DVD disc.
  3. Threshold:  This command displays the threshold value between CD and DVD mirror time.
  4. Save to EEPROM:  This command saves an adjusted mirror time value to the EEPROM.
  5. Default set MIRR time:  This command will set CD and DVD mirror time to firm ware default value.
OPEN CLOSE

Pressing the [EJECT] button controls the tray for disc change during mirror time adjustment.
[0] Return to previous menu.
Press the [0] button on the remote commander to return to previous menu.
EXECUTING MIRROR TIME ADJUSTMENT
In order to execute mirror time adjustment, the following standard procedures must be followed.
  1. Set to the MIRR time Adjust Menu mode.
  2. Press the [5] button on the remote commander to select the “5 Default set MIRR time”.
  3. Press the [3] button on the remote commander to select the “3 Threshold”.
  4. Check the value of Threshold on the screen. If it is 75, go to next step. If it is not so, return to step 2.

MIRR time Adjust Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:
3. Threshold: 75
4. Save to EEPROM
5. Default set MIRR time
[Open] Tray open [Close] Tray close
[0] Return to previous menu
5.  Insert the DVD test disc (HLX-504) (Part No.J-6090-088-A)
6.  Press the [2] button on the remote commander to select the “2 DVD MIRR time Check”.
T.  Wait for hexadecimal value to display on the screen.
8.  Check the value (##) of DVD MIRR time on the screen. If ## is 28 to 70, go to next step. If it is not so, return to step 5.
MIRR time Adjust Menu
1. CD MIRR time Check:
2. DVD MIRR time Check: $$ ##
3. Threshold:
4. Save to EEPROM
5. Default set MIRR time
[Open] Tray open [Close] Tray close
[0] Return to previous menu
9.  Press the [4] button on the remote commander to select the “4.  Save to EEPROM”
10.  Check that $$ is the same as the value of ## on the screen. If it is not so, return to step 5.
11.  Take out the DVD test disc (HLX-504) and insert the CD test disc (YEDS-18) (Part No.3-703-998-01).
12.  Press the [1] button on the remote commander to select the “1.CD MIRR time Check”.
13.  Wait for hexadecimal value to display on the screen.
14  Check the value (@@) of CD MIRR time on the screen. If @ @ is 5A to E8, go to next step. If it is not so, return to step 11.
MIRR time Adjust Menu
1. CD MIRR time Check: && @@
2. DVD MIRR time Check: $$ ##
3. Threshold:
4. Save to EEPROM
5. Default set MIRR time
[Open] Tray open [Close] Tray close
[0] Return to previous menu
15.  Press the [4] button on the remote commander to select the “4.  Save to EEPROM”.
16.  Check that && is the same as the value of @@ on the screen. If it is not so, return to step 11.
17.  Take out the CD test disc (YEDS-18)
18.  Release the MIRR time Adjust Menu mode.

EXECUTING IOP MEASUREMENT
1. Set to the Drive Manual Operation mode.
2. Press the [3] button on the remote commander, and the following Manual Adjust menu will be displayed.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL(PI) Level:
0.     MIRR Time:
[UP]|[DN] Change value
[Return:  Return to previous menu.

3.  Press the [6] button on the remote commander to select the “6. IOP”.
4.  Wait for hexadecimal Value to display on the screen.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop: ED
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
   UP/DN: Change value.
   [Return]:  Return to previous menu
5.  Convert value (ED) from hexadecimal to decimal using conversion table.
6.  If the remainder is smaller than 93 (decimal), then it is OK.  However if the value is higher than 93, then the BU (base unit) is defective and need to be change.
7.  Release the Manual Adjust menu mode.

DVD RAM CLEAR
  • This mode clears DVD data stored in the DVD RAM to initial conditions.
  • On the Rimocon Diagnosis Menu screen, press [4] button on the remote commander to select the “4.Version Information”.
  • Press in order of [MENU] button and [CLEAR] button on the remote commander.
  • Press in order of [MENU] button and [CLEAR] button on the remote commander to clear DVD data.
  • The message “Initialize all data” will be displayed on the screen.
  • The message will change into “Initialize all data Complete” in about six seconds, and the clearness of the DVD data is completed.