SYLVANIA LC370SS9 SERVICE MODE AND POWER SUPPLY CIRCUIT
SYLVANIA LC370SS9
SERVICE MODE AND POWER SUPPLY CIRCUIT
Test Equipment Required
1. DC Voltmeter
2. NTSC Pattern Generator (Color Bar W/White Window, Red Color, Dot Pattern, Gray Scale, Monoscope, Multi-Burst)
3. Remote control unit
4. Color Analyzer
1. DC Voltmeter
2. NTSC Pattern Generator (Color Bar W/White Window, Red Color, Dot Pattern, Gray Scale, Monoscope, Multi-Burst)
3. Remote control unit
4. Color Analyzer
How to make the Service remote control unit:
Cut “A” portion of the attached remote control unit as shown in Fig
Cut “A” portion of the attached remote control unit as shown in Fig
How to set up the service mode:
Service mode:
1. Use the service remote control unit.
2. Turn the power on.
3. Press the service button on the service remote control unit.
Service mode:
1. Use the service remote control unit.
2. Turn the power on.
3. Press the service button on the service remote control unit.
This mode cycles
through full-screen displays of red, green, blue, and white to check for
non-active pixels.
1. Enter the Service mode.
2. Each time pressing [7] button on the service remote control unit, the display changes
1. Enter the Service mode.
2. Each time pressing [7] button on the service remote control unit, the display changes
VCOM Adjustment.
1. Operate the
unit for more than 20 minutes.
2. Set the color analyzer and bring the optical receptor to the center on the LCD-Panel surface after zero point calibration as shown above.
Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
3. Enter the Service mode.
4. Press [3] button on the service remote control unit.
5. Press [CH UP / DOWN] buttons on the service remote control unit so that the color analyzer value becomes minimum.
2. Set the color analyzer and bring the optical receptor to the center on the LCD-Panel surface after zero point calibration as shown above.
Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
3. Enter the Service mode.
4. Press [3] button on the service remote control unit.
5. Press [CH UP / DOWN] buttons on the service remote control unit so that the color analyzer value becomes minimum.
White Balance Adjustment
Purpose: To mix red, green and blue beams correctly for pure white.
Symptom of Misadjustment: White becomes bluish or reddish.
Purpose: To mix red, green and blue beams correctly for pure white.
Symptom of Misadjustment: White becomes bluish or reddish.
1.Operate the
unit for more than 20 minutes.
2. Input the White Raster(70%=70IRE, 25%=25IRE).
2. Input the White Raster(70%=70IRE, 25%=25IRE).
3. Set the color analyzer
to the CHROMA mode and bring the optical receptor to the center on the LCD-Panel
surface after zero point calibration.
Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
4. Enter the Service mode. Press [VOL. n] button on the service remote control unit and select “C/D” mode.
Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
4. Enter the Service mode. Press [VOL. n] button on the service remote control unit and select “C/D” mode.
5. [CUTOFF]
Press [3] button to select “COB” for Blue Cutoff adjustment. Press [1] button to select “COR” for Red Cutoff adjustment.
[DRIVE]
Press [6] button to select “DB” for Blue Drive adjustment. Press [4] button to select “DR” for Red Drive adjustment.
6. In each color mode, press [CH UP / DOWN] buttons to adjust the values of color.
7. Adjust Cutoff and Drive so that the color temperature becomes 12000°K (x= 0.272 / y= 0.278 ±0.005).
Press [3] button to select “COB” for Blue Cutoff adjustment. Press [1] button to select “COR” for Red Cutoff adjustment.
[DRIVE]
Press [6] button to select “DB” for Blue Drive adjustment. Press [4] button to select “DR” for Red Drive adjustment.
6. In each color mode, press [CH UP / DOWN] buttons to adjust the values of color.
7. Adjust Cutoff and Drive so that the color temperature becomes 12000°K (x= 0.272 / y= 0.278 ±0.005).
Initialize the LCD television:
1. Turn the power on.
2. To enter the service mode, press the service button on the service remote control unit.
1. Turn the power on.
2. To enter the service mode, press the service button on the service remote control unit.
- To cancel the
service mode, press [POWER] button on the remote control unit.
3. Press [INFO] button on the service remote control unit to initialize the LCD television.
4. "INITIALIZED" will appear in the upper right of the screen. "INITIALIZED" color will change to green from red when initializing is complete.
3. Press [INFO] button on the service remote control unit to initialize the LCD television.
4. "INITIALIZED" will appear in the upper right of the screen. "INITIALIZED" color will change to green from red when initializing is complete.