SANYO LCD-40XAZ10F HOW TO ENTER TO SERVICE MODE – POWER SUPPLY CIRCUIT
SANYO LCD-40XAZ10F
SERVICE MODE – POWER SUPPLY CIRCUIT
Adjustment instruction
Factory menu
a)First press key ‘Program source’, then press number keys “2,5,8,0” in turn to enter initial factory menu;
b)Press keys UP and DOWN to move cursor to each adjustment page of initial factory menu, then press RIGHT to enter into its adjustment menu;
c) Press keys UP and DOWN to move cursor upwards or downwards within any adjustment page;
d) Press keys LEFT and RIGHT to adjust any item when cursor is moved onto it;
e) Press key “Menu” to exit to initial menu from any adjustment page;
f) Press key “Exit” to exit from factory menu in any case;
g) Set item “Aging Mode” as “On” to enter into factory aging mode.
White balance adjustment
Before adjustment
The unit should be working for above 30 minutes to be in stabler state; Use apparatus CA210 to adjust white balance;
For model of which dimension is bigger than 26”, only 9300K color temperature (that is “normal”) is needed adjustment, To guarantee BBY test requirements to be met when color temperature are 12000K and 6500K, make sure that chromaticity coordinates of bright scale are (X=285±5, Y=293±8) and chromaticity coordinates of dark scale are (X=285±8, Y=293±12); For model of which dimension is 26” or smaller than 26”, only 8000K color temperature (that is “normal”) is needed adjustment, To guarantee test requirements to be met when color temperature are 9300K and 6500K, make sure that chromaticity coordinates of bright scale are X=295±5, Y=305±8) and chromaticity coordinates of dark scale are (X=295±8, Y=305±12);
White balance adjustment of HDMI
Input 16-grey-scale signal with format of 800×600/60 Hz (VG848: Timing is 854, PAT is 921), enter into submenu “color temperature adjustment” of factory menu; For model of which dimension is bigger than 26”, select “normal” color temperature (that is 9300K), fix item “G Offset”, adjust items “R Offset, B Offset” to set chromaticity coordinates of the 3rd scale as ( 285±8, 293±12) and guarantee luminance within the range of 3 nit to 5 nit; fix item “G GAIN”, adjust items “R GAIN, B GAIN” to set chromaticity coordinates of the reverse 3rd scale as ( 285±8, 293±12) ; adjust items “R Offset, B Offset” and “R GAIN, B GAIN” repeatedly until chromaticity coordinates of both scales are all ( 285, 293)
For model of which dimension is 26” and small than 26”, select “normal” color temperature (that is 8000K), fix item “G Offset”, adjust items “R Offset, B Offset” to set chromaticity coordinates of the 3rd scale as ( 295±8, 305±12) and guarantee luminance within the range of 3 nit to 5 nit; fix item “G GAIN”, adjust items “R GAIN, B GAIN” to set chromaticity coordinates of the reverse 3rd scale as 295±5, 305±8 ; adjust items “R Offset, B Offset” and “R GAIN, B GAIN” repeatedly until chromaticity coordinates of both scales are all ( 295, 305); Set item “ALL COLOR” as “ON” after completing adjustment.
Factory menu
a)First press key ‘Program source’, then press number keys “2,5,8,0” in turn to enter initial factory menu;
b)Press keys UP and DOWN to move cursor to each adjustment page of initial factory menu, then press RIGHT to enter into its adjustment menu;
c) Press keys UP and DOWN to move cursor upwards or downwards within any adjustment page;
d) Press keys LEFT and RIGHT to adjust any item when cursor is moved onto it;
e) Press key “Menu” to exit to initial menu from any adjustment page;
f) Press key “Exit” to exit from factory menu in any case;
g) Set item “Aging Mode” as “On” to enter into factory aging mode.
White balance adjustment
Before adjustment
The unit should be working for above 30 minutes to be in stabler state; Use apparatus CA210 to adjust white balance;
For model of which dimension is bigger than 26”, only 9300K color temperature (that is “normal”) is needed adjustment, To guarantee BBY test requirements to be met when color temperature are 12000K and 6500K, make sure that chromaticity coordinates of bright scale are (X=285±5, Y=293±8) and chromaticity coordinates of dark scale are (X=285±8, Y=293±12); For model of which dimension is 26” or smaller than 26”, only 8000K color temperature (that is “normal”) is needed adjustment, To guarantee test requirements to be met when color temperature are 9300K and 6500K, make sure that chromaticity coordinates of bright scale are X=295±5, Y=305±8) and chromaticity coordinates of dark scale are (X=295±8, Y=305±12);
White balance adjustment of HDMI
Input 16-grey-scale signal with format of 800×600/60 Hz (VG848: Timing is 854, PAT is 921), enter into submenu “color temperature adjustment” of factory menu; For model of which dimension is bigger than 26”, select “normal” color temperature (that is 9300K), fix item “G Offset”, adjust items “R Offset, B Offset” to set chromaticity coordinates of the 3rd scale as ( 285±8, 293±12) and guarantee luminance within the range of 3 nit to 5 nit; fix item “G GAIN”, adjust items “R GAIN, B GAIN” to set chromaticity coordinates of the reverse 3rd scale as ( 285±8, 293±12) ; adjust items “R Offset, B Offset” and “R GAIN, B GAIN” repeatedly until chromaticity coordinates of both scales are all ( 285, 293)
For model of which dimension is 26” and small than 26”, select “normal” color temperature (that is 8000K), fix item “G Offset”, adjust items “R Offset, B Offset” to set chromaticity coordinates of the 3rd scale as ( 295±8, 305±12) and guarantee luminance within the range of 3 nit to 5 nit; fix item “G GAIN”, adjust items “R GAIN, B GAIN” to set chromaticity coordinates of the reverse 3rd scale as 295±5, 305±8 ; adjust items “R Offset, B Offset” and “R GAIN, B GAIN” repeatedly until chromaticity coordinates of both scales are all ( 295, 305); Set item “ALL COLOR” as “ON” after completing adjustment.
White balance adjustment of YPbPr
ADC calibration of SD mode: Input color-bar signal with format of 480i/60 Hz (VG848: Timing is 968, PAT is 918), enter into submenu “ADC adjustment” of factory menu and select item “AUTO COLOR”, system will begin calibration automatically, please note whether picture and data are abnormal clearly or not (main abnormal data phenomena are that several data are very different from the other or about 1000 more than the other); it is failed to calibrate ADC if data are abnormal clearly, so it is necessary to do the calibration again;
ADC calibration of HD mode: Input color-bar signal with format of 1080i/60 Hz (VG848: Timing is 972,PAT is 918), enter into submenu “ADC adjustment” of factory menu and select item “AUTO COLOR”, system will begin calibration automatically, please note whether picture and data are abnormal clearly or not (main abnormal data phenomena are that several data are very different from the other or about 1000 more than the other); it is failed to calibrate ADC if data are abnormal clearly, so it is necessary to do the calibration again;
White balance adjustment: Input 16-grey-scale signal with format of 1080i/60 Hz (VG848: Timing is 972, PAT is 921), check if white balance is normal, if not, enter into submenu “color temperature adjustment” of factory menu, set item “ALL COLOR” as “OFF”,
Note: Item “ALL COLOR” must not be altered as “ON” again once set as “OFF”.
White balance adjustment of VGA
Auto-calibration: Input square signal with format of 800×600/60 Hz (VG848: Timing is 854,PAT is CROSS) to do calibration automatically in order to make window filled with picture; ADC calibration: Input monochrome signal with format of 800×600/60 Hz (VG848: Timing is 854, PAT is 948), enter into submenu “ADC adjustment” of factory menu and select item “AUTO COLOR”, system will begin calibration automatically, please note whether picture and data are abnormal clearly or not (main abnormal data phenomena are that several data are very different from the other or about 1000 more than the other); it is failed to calibrate ADC if data are abnormal clearly, so it is necessary to do the calibration again;
White balance adjustment: Input 16-grey-scale signal with format of 800×600/60 Hz (VG848: Timing is 854, PAT is 921), check if white balance is normal, if not, enter into submenu “color temperature adjustment” of factory menu, set item “ALL COLOR” as “OFF”,
Note: Item “ALL COLOR” must not be altered as “ON” again once set as “OFF”.
White balance adjustment of AV
Input 16-grey-scale signal with format of PAL (VG848: Timing is 969, PAT is 921), check if white balance is normal, if not, enter into submenu “color temperature adjustment” of factory menu, set item “ALL COLOR” as “OFF”, please refer to step 4.2.2 to adjust white balance for model of which dimension is 26” , bigger than 26” or smaller than 26” respectively;
Note: Item “ALL COLOR” must not be altered as “ON” again once set as “OFF”.
Auto-white balance adjustment
ADC pre-calibration
Enter into factory menu, set “Program source” as “YPbPr”, input color-bar signal with format of 480i/60 Hz (VG848: Timing is 968,PAT is 918), enter into submenu “ADC adjustment” of factory menu and select item “AUTO COLOR”, system will begin calibration automatically; input color-bar signal with format of 1080i/60 Hz (VG848: Timing is 972, PAT is 918), enter into submenu “ADC adjustment” of factory menu and select item “AUTO COLOR”, system will begin calibration automatically,
Press key “Menu” to be back to upper menu, set “Program source” as VGA”, input monochrome signal with format of 800×600/60 Hz (VG848: Timing is 854,PAT is 948), enter into submenu “ADC adjustment” of factory menu and select item “AUTO COLOR”, system will begin calibration automatically,
White balance adjustment (models except LC-19KC72, LC-22KC72)
TV set should be working for above 30 minutes to be in stabler state before white balance adjustment; connect CA210 to USB port of PC with data line; connect VG848 and TV to COM port of PC or virtual COM port respectively (default connection: VG848 to COM5,TV to COM1, the connection can be altered and saved in administrator window with password “xoceco” if necessary); output signal of VG848 must be sent to AV, YPbPr, VGA and HDMI1 channels of TV; Open program file “White_Balance.exe”, load configure file “AdjustConfig.txt”, then connect CA210, VG848 and TV respectively according to the instruction on interface.
Note: set probe to “0-CAL” before connecting CA210, press “connect CA210”, set probe back to “MEAS” after prompt “CA-210 connection and calibration are normal !” appears on the left-down side; BBY channel is used by CA210 for BBY models, for other models, channels except BBY are used by CA210; please enter into administer window with password “xoceco” to alter and save apparatus setting if it is different;
At last, press “Begin auto-white-balance-adjustment”, auto-adjustment will be completed until prompt “Adjustment is successful” appears.
White balance adjustment (models except LC-19KC72, LC-22KC72)
TV set should be working for above 30 minutes to be in stabler state before white balance adjustment; connect CA210 to USB port of PC with data line; connect VG848 and TV to COM port of PC or virtual COM port respectively (default connection: VG848 to COM5,TV to COM1, the connection can be altered and saved in administrator window with password “xoceco” if necessary); output signal of VG848 must be sent to AV, YPbPr, VGA and HDMI1 channels of TV;
Note: Channel shared by AV/YPBPR must be adjusted respectively. Open program file “White_Balance.exe”, if current working progress includes AV channel, enter into channel setting of administer window to make sure no YPBPR576i@60 but AV is chosen, or load configure file “AdjustConfigAV.txt”; if current working progress includes YPBPR channel, enter into channel setting of administer window to make sure no AV but YPBPR576i@60 is chosen, or load configure file “AdjustConfigYPBPR.txt.txt”; then connect CA210, VG848 and TV respectively according to the instruction on interface.
Note: set probe to “0-CAL” before connecting CA210, press “connect CA210”, set probe back to “MEAS” after prompt “CA-210 connection and calibration are normal !” appears on the left-down side; BBY channel is used by CA210 for BBY models, for other models, channels except BBY are used by CA210; please enter into administer window with password “xoceco” to alter and save apparatus setting if it is different;
At last, press “Begin auto-white-balance-adjustment”, auto-adjustment will be completed until prompt “Adjustment is successful” appears.
ADC calibration of SD mode: Input color-bar signal with format of 480i/60 Hz (VG848: Timing is 968, PAT is 918), enter into submenu “ADC adjustment” of factory menu and select item “AUTO COLOR”, system will begin calibration automatically, please note whether picture and data are abnormal clearly or not (main abnormal data phenomena are that several data are very different from the other or about 1000 more than the other); it is failed to calibrate ADC if data are abnormal clearly, so it is necessary to do the calibration again;
ADC calibration of HD mode: Input color-bar signal with format of 1080i/60 Hz (VG848: Timing is 972,PAT is 918), enter into submenu “ADC adjustment” of factory menu and select item “AUTO COLOR”, system will begin calibration automatically, please note whether picture and data are abnormal clearly or not (main abnormal data phenomena are that several data are very different from the other or about 1000 more than the other); it is failed to calibrate ADC if data are abnormal clearly, so it is necessary to do the calibration again;
White balance adjustment: Input 16-grey-scale signal with format of 1080i/60 Hz (VG848: Timing is 972, PAT is 921), check if white balance is normal, if not, enter into submenu “color temperature adjustment” of factory menu, set item “ALL COLOR” as “OFF”,
Note: Item “ALL COLOR” must not be altered as “ON” again once set as “OFF”.
White balance adjustment of VGA
Auto-calibration: Input square signal with format of 800×600/60 Hz (VG848: Timing is 854,PAT is CROSS) to do calibration automatically in order to make window filled with picture; ADC calibration: Input monochrome signal with format of 800×600/60 Hz (VG848: Timing is 854, PAT is 948), enter into submenu “ADC adjustment” of factory menu and select item “AUTO COLOR”, system will begin calibration automatically, please note whether picture and data are abnormal clearly or not (main abnormal data phenomena are that several data are very different from the other or about 1000 more than the other); it is failed to calibrate ADC if data are abnormal clearly, so it is necessary to do the calibration again;
White balance adjustment: Input 16-grey-scale signal with format of 800×600/60 Hz (VG848: Timing is 854, PAT is 921), check if white balance is normal, if not, enter into submenu “color temperature adjustment” of factory menu, set item “ALL COLOR” as “OFF”,
Note: Item “ALL COLOR” must not be altered as “ON” again once set as “OFF”.
White balance adjustment of AV
Input 16-grey-scale signal with format of PAL (VG848: Timing is 969, PAT is 921), check if white balance is normal, if not, enter into submenu “color temperature adjustment” of factory menu, set item “ALL COLOR” as “OFF”, please refer to step 4.2.2 to adjust white balance for model of which dimension is 26” , bigger than 26” or smaller than 26” respectively;
Note: Item “ALL COLOR” must not be altered as “ON” again once set as “OFF”.
Auto-white balance adjustment
ADC pre-calibration
Enter into factory menu, set “Program source” as “YPbPr”, input color-bar signal with format of 480i/60 Hz (VG848: Timing is 968,PAT is 918), enter into submenu “ADC adjustment” of factory menu and select item “AUTO COLOR”, system will begin calibration automatically; input color-bar signal with format of 1080i/60 Hz (VG848: Timing is 972, PAT is 918), enter into submenu “ADC adjustment” of factory menu and select item “AUTO COLOR”, system will begin calibration automatically,
Press key “Menu” to be back to upper menu, set “Program source” as VGA”, input monochrome signal with format of 800×600/60 Hz (VG848: Timing is 854,PAT is 948), enter into submenu “ADC adjustment” of factory menu and select item “AUTO COLOR”, system will begin calibration automatically,
White balance adjustment (models except LC-19KC72, LC-22KC72)
TV set should be working for above 30 minutes to be in stabler state before white balance adjustment; connect CA210 to USB port of PC with data line; connect VG848 and TV to COM port of PC or virtual COM port respectively (default connection: VG848 to COM5,TV to COM1, the connection can be altered and saved in administrator window with password “xoceco” if necessary); output signal of VG848 must be sent to AV, YPbPr, VGA and HDMI1 channels of TV; Open program file “White_Balance.exe”, load configure file “AdjustConfig.txt”, then connect CA210, VG848 and TV respectively according to the instruction on interface.
Note: set probe to “0-CAL” before connecting CA210, press “connect CA210”, set probe back to “MEAS” after prompt “CA-210 connection and calibration are normal !” appears on the left-down side; BBY channel is used by CA210 for BBY models, for other models, channels except BBY are used by CA210; please enter into administer window with password “xoceco” to alter and save apparatus setting if it is different;
At last, press “Begin auto-white-balance-adjustment”, auto-adjustment will be completed until prompt “Adjustment is successful” appears.
White balance adjustment (models except LC-19KC72, LC-22KC72)
TV set should be working for above 30 minutes to be in stabler state before white balance adjustment; connect CA210 to USB port of PC with data line; connect VG848 and TV to COM port of PC or virtual COM port respectively (default connection: VG848 to COM5,TV to COM1, the connection can be altered and saved in administrator window with password “xoceco” if necessary); output signal of VG848 must be sent to AV, YPbPr, VGA and HDMI1 channels of TV;
Note: Channel shared by AV/YPBPR must be adjusted respectively. Open program file “White_Balance.exe”, if current working progress includes AV channel, enter into channel setting of administer window to make sure no YPBPR576i@60 but AV is chosen, or load configure file “AdjustConfigAV.txt”; if current working progress includes YPBPR channel, enter into channel setting of administer window to make sure no AV but YPBPR576i@60 is chosen, or load configure file “AdjustConfigYPBPR.txt.txt”; then connect CA210, VG848 and TV respectively according to the instruction on interface.
Note: set probe to “0-CAL” before connecting CA210, press “connect CA210”, set probe back to “MEAS” after prompt “CA-210 connection and calibration are normal !” appears on the left-down side; BBY channel is used by CA210 for BBY models, for other models, channels except BBY are used by CA210; please enter into administer window with password “xoceco” to alter and save apparatus setting if it is different;
At last, press “Begin auto-white-balance-adjustment”, auto-adjustment will be completed until prompt “Adjustment is successful” appears.
Software upgrade
Instruction of software upgrade for KC# model:
1. Save upgrade file “flash.img” into the root directory of a U disk;
2. Insert the U disk into USB port of TV set, press key “power” until TV set is in“standby” state, then power on TV set again;
3. Press key “program source” until menu “program source” display, then press keys “2”, “5”, “8”, “0” by turn to enter into factory menu
Instruction of software upgrade for KC# model:
1. Save upgrade file “flash.img” into the root directory of a U disk;
2. Insert the U disk into USB port of TV set, press key “power” until TV set is in“standby” state, then power on TV set again;
3. Press key “program source” until menu “program source” display, then press keys “2”, “5”, “8”, “0” by turn to enter into factory menu
4. Press keys of remote control “UP”,”DOWN” to
select item “ISP”, press key “enter” to begin updating progress, a prompt
“Updating, Pls, Waiting…” is displaying, wait for a while until menu display.
5. TV set will auto-reset after completing
update, according to step1 and step
2, enter into factory menu again to confirm updating completion by checking the time of update file.
2, enter into factory menu again to confirm updating completion by checking the time of update file.
POWER SUPPLY CIRCUIT
CLICK ON THE IMAGE TO ZOOM IN