SHARP AQUOS- LC-26/32D44EE-BK/GY - LC-26/32D44ES-BK/GY - LC-26/32D44EK-BK/GY - LC-26/32D44RU-BK/GY - TUNER LEVEL ADJUSTMENT - WHITE BALANCE ADJUSTMENT FROM PC - HOTEL MODE
LC-26/32D44EE-BK/GY à Continental
LC-26/32D44ES-BK/GY à Sweden Market
LC-26/32D44EK-BK/GY à United Kingdom
LC-26/32D44RU-BK/GY à Russian MarketTUNER LEVEL ADJUSTMENT
WHITE BALANCE [W/B] ADJUSTMENT FROM PC
- Get ready the PC with COM port (RS-232C) running on Windows 95/98/ME/2000/XP operating system, as well as the RS-232C cross cable.
- Start the unit with the RS-232C cable connected.
- Start the terminal software. (The freeware readily available on the Internet will do.)
Baud rate à 9.600 bps
Data LENGTH à 8 bit
Parity bit à None
Stop bit à 1 bit
Flow control à None
- If the settings are correct, the terminal software indicates, “ERR” against pressing of the “ENTER” key.
- After the setting is done correctly, it is possible to make an adjustment by typing in the command shown in the table below and pressing the “ENTER” key on the keyboard.
- Command entry is successful if the terminal software indicates “OK” when the “ENTER” is pressed. If “ERR” is shown, retry to enter the command.
- Send the process mode switching command to switch from the RS232C operation mode to the process mode:
KT10037 : When “OK”
is returned, the process mode becomes active. When “ERR”, start over from
KRSW0001.
- Send each adjustment command.
RS-232C COMMAND LIST
To ensure that TVs are not red, have changed the W/B coordinates
adjustment:
x: 270
y: 286
Click on image to Enlarge
HOTEL MODE
To enter in the Public Mode [Hotel Mode]
There are three following ways to display the Public Mode
setting screen.
- On the process adjustment mode screen (2/33), set the “HOTEL MODE” Flag to ON. Turn off the power, and turn it on again, pressing the CH▲ and Vol▲ keys of the main unit at the same time.
- Enter the Pass Word, and start the unit.
- Turn on the power, pressing the INPUT and Vol▲ keys of the main unit at the same time.
- Display the Pass Word input screen.
- Check the Pass Word by inputting three digits. If the Pass Word is 0 2 7 , it shifts to the Public Mode setting screen. In another case, the screen is erased, and it operates in the ordinary mode.
After one of sequence before mentioned, the TV will
turn on showing the Public Mode setting screen.
TO EXIT PUBLIC MODE
There are two following ways to exit the Public Mode setting
screen.
- Turn off the power.
- Select “Execute” in the Public Mode to execute it.
PUBLIC MODE SETTINGS
POWER ON FIXED[VARIABLE ó FIXED]
When it is set to “FIXED” the TV is impossible to be switch
off by Main Switch or Remote Control.
MAXIMUM VOLUME[0 ó 60]
Is possible to set the maximum volume at limited level.
VOLUME FIXED[VARIABLE ó FIXED]
Is possible to fi x the sound volume at limited level.
When “FIXED” is selected the sound volume before limited is
fixed.
VOLUME FIXED LEVEL [0 <=>]
If “FIXED” has been selected, is possible to set a fixed
volume at the level that is chosen.
RC BUTTON [RESPOND ó NO RESPOND]
If “NO RESPOND” is selected, the remote control keys are
inoperative.
PANEL BUTTON[RESPOND ó NO RESPOND]
If “NO RESPOND” has been selected, the set´s keys remain
deactivated (Except POWER key).
MENU BUTTON[RESPOND ó NO RESPOND]
If “NO RESPOND” has been selected, “MENU” keys on the remote
control, is inoperative.
ON SCREEN DISPLAY[YES óNO]
If “NO” has been selected, the On Screen Display does not
appear.
INPUT MODE START[ NORMAL=>TV (X) => DTV => INPUT1 =>
INPUT2 =>INPUT3 => INPUT4 => INPUT5 => INPUT6 => INPUT7 ó
When any other item than “NORMAL” has been selected, the
sets will start in a selected input mode at the next power-on.
INPUT MODE FIXED[VARIABLE óFIXED]
If “FIXED” has been selected, any channels and input modes
other than those selected at the start mode cannot be picked up.
RESET
Cancel all Public Mode settings. (It returns to the factory
settings)
EXECUTE
Select this item, and press Cursor Right/Left keys on
the remote control, or Vol Up/Dn keys on the LCD TV for confirmation the
functions settings.