SHARP LC-26P55E -LC-32P55E - LC-37P55E SERVICE MODE AND POWER SUPPLY CIRCUIT
SHARP LC-26P55E -LC-32P55E - LC-37P55E
SERVICE MODE AND POWER SUPPLY CIRCUIT
SERVICE MODE
Entering and exiting the
adjustment process mode
1- Unplug the AC power cord of TV set to force power off.
2- While holding down the “VOL (–)” and “INPUT” keys on the set at once, plug in the AC power cord to turn on the set. The letter K appears on the screen: “K” color guide:
3- Next, hold down the “VOL (—)” and “P (—)” keys on the set at once. Multiple lines of orange characters appear ing onscreen indicate that the set is now in the adjustment process mode. If you fail to enter the adjustment process mode (the display is the same as normal startup), retry the procedure.
4- To exit the adjustment process mode after the adjustment is done, unplug the AC power cord to force off the
power. (When the power is turned off with the remote controller, once unplug the AC power cord and plug it in again. In this case, wait 10 seconds or so before plugging.)
1- Unplug the AC power cord of TV set to force power off.
2- While holding down the “VOL (–)” and “INPUT” keys on the set at once, plug in the AC power cord to turn on the set. The letter K appears on the screen: “K” color guide:
3- Next, hold down the “VOL (—)” and “P (—)” keys on the set at once. Multiple lines of orange characters appear ing onscreen indicate that the set is now in the adjustment process mode. If you fail to enter the adjustment process mode (the display is the same as normal startup), retry the procedure.
4- To exit the adjustment process mode after the adjustment is done, unplug the AC power cord to force off the
power. (When the power is turned off with the remote controller, once unplug the AC power cord and plug it in again. In this case, wait 10 seconds or so before plugging.)
Note: Use due care in handling the
information described here lest the users should know how to enter the adjustment process mode. If the settings tampered with
in this mode, unrecoverable system damage may result.
POWER SUPPLY CIRCUIT
LC-26P55E
LC-32P55E
LC-37P55E