SONY KDL-40EX520 - KDL-40EX523 -KDL-46EX520 -KDL-46EX523 - Service mode - Self diagnostics – LED blinking code - White balance Adjustment - LED Television Repair and service
Category: LED Television Repair and Service
Contents of this article
- How to access to service mode
- LED Blinking Codes and causes
- White balance adjustment
SONY KDL-40EX520 - KDL-40EX523 -KDL-46EX520 -KDL-46EX523
Self Diagnostic Menu
1. While LCD TV set is on standby mode, press
the following sequence on the Remote Commander key.
i+ >5 >Vol Down >TV Power
i+ >5 >Vol Down >TV Power
2.To Reset Error Count & Error History:
Press 8 > 0 key
3. To Reset Panel Operation Time (Applicable
Only when Panel is replaced): Press < 7 >
< 0 > key
4.To exit, turn the power off using Remote
Commander key.
SELF DIAGNOSTIC FUNCTION
Blinking Times
|
Error
|
Countermeasure to replaced
|
2
|
Main
Power Error
|
Power Supply Board Main Board |
3
|
Main
Board / DC Alert
Error / Audio Error |
Main
Board
|
4
|
Balancer
Error / MM
SPI Error / VLED Error |
Not
applicable for this
|
5
|
Tcon
Error / HFR Error /
FRC No |
Not
applicable for this
|
Panel
ID NVM Error
|
Tcon
Panel Module |
|
6
|
Backlight
Error
|
Power
Supply Board
Main Board Panel |
7
|
Temperature
Error
|
Main
Board
|
8
|
Software
Error
|
Main
Board
Wifi (Not applicable for this manual) |
10
|
Emitter
Board Power
Error |
Not
applicable for this m
|
SERVICE MODE
Accessing Service Mode
While LCD TV set is on standby mode, press the following sequence
on the Remote Commander key.
Display > CHANNEL 5 > Vol Up > Power
2. Digital Service Mode will be appeared
first whenever entering Service Mode.
3. To changed the module, please press either OPTION or JUMP key on the remote commander.
3. To changed the module, please press either OPTION or JUMP key on the remote commander.
Change data by Service Mode 1 (Chassis and VPC module)
1. To change category, item and data in
CHASSIS or VPC service mode:
a. Press key 2 or 5 on remote commander to select (up or down) category.
b. Press key 1 or 4 on remote commander to select (up or down) Item.
c. Press key 3 or 6 on remote commander to change(up or down) data.
Remote commander key : 1, 2, 3 is for increment
Remote commander key : 4, 5, 6 is for decrement
a. Press key 2 or 5 on remote commander to select (up or down) category.
b. Press key 1 or 4 on remote commander to select (up or down) Item.
c. Press key 3 or 6 on remote commander to change(up or down) data.
Remote commander key : 1, 2, 3 is for increment
Remote commander key : 4, 5, 6 is for decrement
2. To save changed data in Service Mode 1
a. Press key Mute on remote commander. It shows green SERVICE changes to green WRITE.
b. Press key 0. Green WRITE changes to red WRITE. It indicate writing is processing.
c. After a while, red WRITE changes to green SERVICE. Writing process is done at this point.
3. TV reboot is necessary for applying data change.
a. Press key Mute on remote commander. It shows green SERVICE changes to green WRITE.
b. Press key 0. Green WRITE changes to red WRITE. It indicate writing is processing.
c. After a while, red WRITE changes to green SERVICE. Writing process is done at this point.
3. TV reboot is necessary for applying data change.
Change data by Service Mode 2
(Digital Service Mode)
Change data for all Except 003 DIG_SRV_MODE
Change data for all Except 003 DIG_SRV_MODE
To change category, item and data in DIGITAL
service mode (except 003 DIG_SRV_MODE category):
a. Press key 2 or 5 on remote commander to select (up or down) category.
b. Press key 1 or 4 on remote commander to select (up or down) Item.
c. Press key 3 or 6 to change (up or down) data.
Remote commander key : 1, 2, 3 is for increment
Remote commander key : 4, 5, 6 is for decrement
No need to save for Digital Service Mode (except for 002 MODEL & 005 CHPRESET category)
Change data for 003 DIG_SRV_MODE
To change item and data in DIGITAL service mode (003 DIG_SRV_MODE category):
Please note because this operation is special.
a. Press key 2 or 5 on remote commander to select 003 DIG_SRV_MODE.
b. Press key 1 or 4 on remote commander to select (up or down) Item.
c. Press key 0 or 10 on remote commander to select item.
d. Press key 1~9 on remote commander directly. Star (*) mark will move accordingly.
e. Press key ENTER or SELECT to decide and advance next step.
Press Remote Commander key RETURN to return to the previous page.
a. Press key 2 or 5 on remote commander to select (up or down) category.
b. Press key 1 or 4 on remote commander to select (up or down) Item.
c. Press key 3 or 6 to change (up or down) data.
Remote commander key : 1, 2, 3 is for increment
Remote commander key : 4, 5, 6 is for decrement
No need to save for Digital Service Mode (except for 002 MODEL & 005 CHPRESET category)
Change data for 003 DIG_SRV_MODE
To change item and data in DIGITAL service mode (003 DIG_SRV_MODE category):
Please note because this operation is special.
a. Press key 2 or 5 on remote commander to select 003 DIG_SRV_MODE.
b. Press key 1 or 4 on remote commander to select (up or down) Item.
c. Press key 0 or 10 on remote commander to select item.
d. Press key 1~9 on remote commander directly. Star (*) mark will move accordingly.
e. Press key ENTER or SELECT to decide and advance next step.
Press Remote Commander key RETURN to return to the previous page.
White Balance Adjustment
To access to White Balance Service mode,
choose VPC Service Mode.
a. Press key 1 or 4 on remote commander to select WB adjustment menu. 006 WB category will be seen on the menu.
b. Change data by pressing 3 or 6. Each range of these items is 0~255.
c. Press mute + 0 on remote commander to save the data. SERVICE comment is changed to WRITE, indicating writing process.
d. After a while, WRITE comment returns to SERVICE, which means writing process is done. (takes about a couple of seconds)
Restore WB / Gamma adj-data to B board.
a. Press key 1 or 4 on remote commander to select WB adjustment menu. 006 WB category will be seen on the menu.
b. Change data by pressing 3 or 6. Each range of these items is 0~255.
c. Press mute + 0 on remote commander to save the data. SERVICE comment is changed to WRITE, indicating writing process.
d. After a while, WRITE comment returns to SERVICE, which means writing process is done. (takes about a couple of seconds)
Restore WB / Gamma adj-data to B board.
In VPC service mode:
a. Select 000 DATA_COPY category by pressing key 2 or 5 on remote commander.
b. Change data from 0 to 1 by pressing key 3 or 6 on remote commander.
c. Wait until data is changed from 1 to 3.
d. When data is changed from 1 to 3, restoring process is finished.
e. In case data is changed from 1 to 2, keep default setting. (No more process is needed.)
a. Select 000 DATA_COPY category by pressing key 2 or 5 on remote commander.
b. Change data from 0 to 1 by pressing key 3 or 6 on remote commander.
c. Wait until data is changed from 1 to 3.
d. When data is changed from 1 to 3, restoring process is finished.
e. In case data is changed from 1 to 2, keep default setting. (No more process is needed.)
Notes:
1. This restoration should be applied after USB-DL being assembled when B Board is replaced.
2. This process only applicable for 120Hz / 240Hz models only.
1. This restoration should be applied after USB-DL being assembled when B Board is replaced.
2. This process only applicable for 120Hz / 240Hz models only.
Change the emitter output level
1. Purpose to reduce the emitter LED output power strength.
2. Select VPC service mode and then press:
a. Select 005 TD category by pressing key 2 or 5 on remote commander.
b. Select 000 EMIT_STR item by pressing key 1 or 4 on remote commander.
c. Change data from 0 to 1 by pressing key 3 or 6 on remote commander.
0: Strong (Default)
1: Weak
d. Save by pressing Mute & 0 or 10 & Reboot.
1. Purpose to reduce the emitter LED output power strength.
2. Select VPC service mode and then press:
a. Select 005 TD category by pressing key 2 or 5 on remote commander.
b. Select 000 EMIT_STR item by pressing key 1 or 4 on remote commander.
c. Change data from 0 to 1 by pressing key 3 or 6 on remote commander.
0: Strong (Default)
1: Weak
d. Save by pressing Mute & 0 or 10 & Reboot.
VCOM Test Pattern
Step 1
Step 1
To access VCOM Step 1, please select Digital
Service Mode first
a. Select 003 DIG_SRV_MODE category by pressing key 2 or 5 on remote
commander.
b. Press key 0 on remote commander to go to TEST PATTERN Mode.
c. Press key Enter or 1 or 2 on remote commmander to go into Video TEST PATTERN.
d. Press key 7 or 8 on remote commander to select the test pattern
e. Press key Enter or Select on remote commander twice to show the VCOM
Step 2
To access VCOM Step 2, please select VPCService Mode first
a. Select 003 DIG_SRV_MODE category by pressing key 2 or 5 on remote
commander.
b. Press key 0 on remote commander to go to TEST PATTERN Mode.
c. Press key Enter or 1 or 2 on remote commmander to go into Video TEST PATTERN.
d. Press key 7 or 8 on remote commander to select the test pattern
e. Press key Enter or Select on remote commander twice to show the VCOM
Step 2
To access VCOM Step 2, please select VPCService Mode first
a. Select 002 VCOM category by
pressing key 2 or 5 on remote commander.
b. Select 000 ENABLE item by pressing key 1 or 4 on remote commander.
c. Change ENABLE from 0 to 1 to enable VCOM adjustment.
b. Select 000 ENABLE item by pressing key 1 or 4 on remote commander.
c. Change ENABLE from 0 to 1 to enable VCOM adjustment.
Step 3
To access VCOM Step 3, please select VPC
Service Mode.
a. Select 002 VCOM category by pressing key 2 or 5 on remote commander.
b. Select 001 ADJUST item by pressing key 1 or 4 on remote commander.
c. Change data by pressing key 3 or 6 on remote commander.
d. Finish the adjustment when the picture seems OK.
a. Select 002 VCOM category by pressing key 2 or 5 on remote commander.
b. Select 001 ADJUST item by pressing key 1 or 4 on remote commander.
c. Change data by pressing key 3 or 6 on remote commander.
d. Finish the adjustment when the picture seems OK.
Step 4
To
access VCOM Step 4, please select Digital Service .a. Select 007 VCOM category by pressing key 2 or 5 on remote commander.
b. Change data from 1 to 0 by pressing key 3 or 6 on remote commander.
c. Confirm the final result of the VCOM adjustment .
d. If OK, Finish the VCOM adjustment. If NG, pressing key 3 or 6 to show the OSD again and go back to VCOM adjustment STEP3.