REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Showing posts with label SABA. Show all posts
Showing posts with label SABA. Show all posts

Friday, 1 March 2019

HOW TO ENTER SERVICE MODE TO TVS – SABA, TOSHIBA, SHARP, SAMSUNG, TELEFUNKEN, FINLUX, DIGIVISION

How to enter Service Mode to TVs – Saba, Toshiba, Sharp, Samsung, Telefunken, Finlux, Digivision

Universum, Thomson, Saba, Telefunken, Siemens, Silva, Sharp, Schneider and more……
Akai CT-2119 CTV Test Mode Simultaneous press [+] & [-] on local panel and then power on with main switch. Exit: POWER. Allstar 3750 CTV Hotel Mode OFF: Select program 38. Simultaneous press (3 sec) STORE & CONTROL+ on local keyboard. ON: Select program 38. Simultaneous press (3 sec) STORE & PROGRAM- on local keyboard. AudioTon CTV 5502 10.3 90° MONO CTV  Child Lock Clear Press UP & DOWN buttons together on TV's local control and then switch on. You will see  SERVICE MODE.  Do not press any button, just power off the set, then on. The child lock will be cleared. AudioTon CTV 5502 10.3 90° MONO CTV Service Mode  Press UP & DOWN buttons together on TV's local control and then switch on. Beko CTV Service Mode  Simultaneous press P+ & P- on local panel and then power on with main switch. Blaupunkt MM63-13VT FM240.00 CTV ATS Press button P/C on RC and switch on TV with main switch. Blaupunkt MM63-13VT FM240.00 CTV Hotel Mode Cancel Press button 'i' on RC and switch on TV with main switch. Brandt ICC9 CTV Service Mode Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off.  Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again. (WARNING: SCART should be free.) Continental CT1412B CTV Service Mode  Press and hold P+ and P- on local panel, then switch on TV with main switch. Ferguson ICC9 CTV Service Mode Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again. (WARNING: SCART should be free.) Ferguson TX92 CTV Hotel Mode Cancel Put TV into standby, then turn power off, then turn power on whilst holding standby button on remote and step through menus to `vol set` and increase level to max.
Finlux 17/21B60 63/71Y2 STEREO PLUS CTV Service Mode MUTE --> OK (M) --> TV Controls: cursor buttons. Store: OK (M). Exit: TV GoldStar MC-51B CTV Service Mode Simultaneously Press MENU, VOL-, PR- on the local panel. Digivision DIGI III 110° CTV Service Mode Turn on 'TV Internal Service Program' switch on the digital module (SE on display). On RC:  1=U1 V SHIFT, 2=U2 V LIN DN, 3=U3 V LIN, 4=H1 H SHIFT, 5=H2 H AMP, 6=H3 EW AMP, 7= C, 8=C1, 9=C2, 0=H4 EW TRAPEZ… TV=MEMO, VOL+/-=ADJUST. ITT STEREO PLUS CTV Service Mode MUTE --> OK (M) --> TV Controls: cursor buttons. Store: OK (M). Exit: TV LG MC64 CTV Service Mode  Simultaneous press OK on RC & local panel. LG MC84 CTV Service Mode  Simultaneous press OK on RC & local panel. Loewe. Art.-Nr. 64420 66426 66449 66450 66460 66480 66490 C9000 CTV TV Service Mode Simultaneous press CM on the RC & "Service" key on the control panel. Select: MEM IN/OUT. Adjust: VOL +/-. Store: X. Exit: TV. Loewe. Art.-Nr. 64420 66426 66449 66450 66460 66480 66490 C9000 CTV VT Service Mode Simultaneous press VT on the RC & "Service" key on the control panel. Select: MEM IN/OUT. Adjust: VOL +/-. Store: X. Exit: TV. Loewe. C9003 CTV Service Mode On the local control press function key five times (indication "Service" will appear), afterwards within a sec. press key "MEN" on the remote control. Store: X.  Exit: TV. Loewe. Q2200 CTV Service Mode Go to 'SERVICE' in menu and then quick press 'MENU' on the RC.  Select: yellow cursors. Adjust: +/-. Store: 'X'. Exit: 'TV'. Luxor 5585-21A1 7057-27 63/7954 STEREO PLUS CTV Service Mode MUTE --> OK (M) --> TV Controls: cursor buttons. Store: OK (M). Exit: TV Mitsubishi CT21M5E CTV Service Mode  Press S701 (on board) and button 9 (in 5s). Store: '0'. Exit: stand-by. NEC XExx XPxx XVxx MON Service Mode Select DISPLAY MODE. Press PROCEED. Press and hold RESET. Then simultaneous press + & -. 'Warning Entering Service Menu…' appears.  Press PROCEED for enter. Be careful Nokia 6364, 7364 2B-F CTV Service Mode  Quick press: --\-, MENU, TV. Nokia EUROSTEREO CTV Service Mode In 1s press buttons '-/--', 'MENU', 'TV'. Select: PR+/-. Adjust: VOL+/-. Store: fill-dot-symbol on RC (near 'i' button).  Exit: 'STANDBY'. Nokia 63/7168 55A1-0 45H1-0 55Y2-0 63/7157 63/7177 STEREO PLUS CTV Service Mode MUTE --> OK (M) --> TV Controls: cursor buttons. Store: OK (M). Exit: TV Nokia STEREO PLUS CTV Service Mode i --> M --> PROGR. Controls: cursor buttons. Store: M. Exit: TV Nordmende DC1 CTV Service Mode Switch to Standby. Switch off with the mains switch. Press and hold red button on RC and then switch on with the mains switch (cca 10s). Select: numbers buttons. Adjust: +/-. Store: red button. Exit: 'MUTE'. Nordmende DC2 CTV Service Mode Switch to Standby. Switch off with the mains switch. Press and hold red button on RC and then switch on with the mains switch (cca 10s). Select: numbers buttons. Adjust: +/-. Store: red button. Exit: 'MUTE'. Nordmende Color 3038 F15-03 110° CTV MDA2061 Replacement After replacement of the MDA2061 (IR73) the TV receiver acts as folows:  a) All program storage have stored Ch00.  b) The indicator shows German function characters.  c) PAL and SECAM EAST standard reception is possible (not NTSC and/or SECAM WEST). If required to change according to paragraph. b and c then switch off the set by the mains switch. Press both buttons + and - for volume on TV and simultaneously switch the set on with the mains switch. Keep the two volume buttons pressed until the display indicates Pr. after 8s the display indicates __. Now the following buttons can be pressed on the RC, thus additional corresponding segments will be illuminated: Button '1' function symbols indicate international display. Reversible to German display with button '2'. Button '5' additional SECAM WEST and/or NTSC reception (Multistandard). Reversible to Single Standard with button '3'.  Store: Stand-By. Nordmende ICC10 CTV Service Mode Switch to Stand By. Switch off with the mains switch. Press and hold 'VT' on RC then switch on with the mains switch. Nordmende ICC9 CTV Service Mode Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press blue button on RC and switch on TV with main switch. Press blue button again. (WARNING: scart must be free.) Palladium TV-100 CTV Service Mode Simultaneous press red & blue buttons on RC then (in 5 sec.) simultaneously press P- & P+ on local keyboard. Commands: arrows.  Store: OK.  Exit: TV. Panasonic EURO-1 CTV Service Mode In Sound-Menu Low-tone-regel to MAX and High-tone-regel to MIN. Press VOL- on TV and RESET on RC in some time.  Select: red and green buttons.  Adjust: yellow and blue buttons.  Store: 'STORE'. Exit: switch off. Panasonic EURO-2 CTV Service Mode In Sound-Menu Low-tone-regel to MAX and High-tone-regel to MIN. Press 'F' button on TV.  Then press VOL- on TV and REVEAL on RC in some time. Select: red and green buttons. Adjust: yellow and blue buttons. Store: 'STR'. Exit: 'N' on RC. Panasonic MX-3 MX-3C CTV Hotel Mode ON: Press simultaneously 'OFF TIMER' on RC and 'CH.UP' local. OFF: Press simultaneously 'OFF TIMER' on RC and 'VOL-' local. Panasonic MX-3 MX-3C CTV Service Mode Simultaneously press 'RECALL' on RC and 'VOL-' local. Exit: 'NORMAL' on RC. Philips ANUBIS B CTV Hotel Mode ON: Set HOTEL ON in Service Menu. Select programm 38. Simultaneous press (3 sec) INSTALL & P- on local keyboard. OFF: Set HOTEL OFF in Service Menu. Philips ANUBIS B CTV Service Mode  Simultaneously press VOL+ & P- on RC. Exit: STANDBY. Philips Anubis S CTV Hotel Mode OFF: Select program 38. Simultaneous press (3 sec) PR+ & VOL- on local keyboard. ON: Select program 38. Simultaneous press (3 sec) STORE & PR- on local keyboard. Philips L7.1A CTV Service Mode  With special service RC. Or short M25, M25 on board and then switch on TV. Exit: st-by. Philips L9.1 CTV Hotel Mode Select program 38 on the TV. Simultaneously press the keys VOLUME- and VOLUME+ on the keyboard of the TV and the OSD key of the remote control. Philips L9H CTV Service Mode This model also supports the 062596 sequence followed by [MENU] (service default) or [i+]/[OSD] (service mode). Philips MD1.2E CTV Service Mode There is a small Service jumper to short on the small signal PCB. When the TV is in this first level service mode, you can go in the second level service mode by pressing both MENU and - keys on top of the TV at the same time. There you can read much parameters and proceed with most of the adjustments. In fact this method let you use an ordinary Remote control but you also need to open the back cover. With the special service remote control, a special code is sent to enter the service mode. Philips MG3.1E CTV Service Mode Option 1: In the TV-set itself is a 3-pin connector with which either SERVICE-DEFAULT or SERVICE-MODE can be activated. This connector is depicted 0356 (SERVICE-PINS) on page K7 (TXT&CONTROL).  Shorting pins 1-2 will activate SERVICE-MODE. Shorting pins 2-3 will activate SERVICE-DEFAULT.  Option 2: Activate these modes using the remote control. Obviously option 2 is the preferred method because the settings have to be changed using a remote control anyway.... To activate SERVICE-DEFAULT: Press 0 6 2 5 9 6 and then the [menu] button. The message ‘Service Default’ appears and channel ‘SER T’ will be selected. This only sets some settings to a preset value (color/brightness/volume and such). This mode is primarily intended to be used when the non volatile memory has been replaced. It is then loaded with the default values. To activate SERVICE-MODE: Press 0 6 2 5 9 6 and then the [i+] button. After pressing 0 6 2 5 9 6 the message ‘Dealer’ should have appeared. Do not worry about the channel changing while you press the numbers.  Service technicians have the means of entering service mode using a special remote control. Philips 29PT9416 MG7.1 CTV Service Mode Use the standard remote control an key in a special sequence 0 6 2 5 9 6 followed by pressing the 'MENU' button. If the main menu also appears with the service menu just press 'MENU' again to clear it. The other way is to short the two service pins on the signal panel (pins 2 and 3 of connector 0356). The advantage of this last method is that all the software protections are turned off. Philips Y6 CTV Service Mode Use the standard remote control an key in a special sequence 0 6 2 5 9 6 followed by pressing the 'MENU' button. If the main menu also appears with the service menu just press 'MENU' again to clear it. Philips VR210/58 VCR Modulator off Without cassette. Press and hold SYSTEM till 'G591' appears. Press and hold CLEAR (CL) till 'MOFF' appears. Exit: TV/STANBY. Philips VR210/58 VCR Modulator on Without cassette. Press and hold SYSTEM till 'MOFF' appears. Press and hold CLEAR (CL) till 'G591' appears. Exit: TV/STANBY. Philips VR220/58 VCR Child Lock Cancel Press CHILD LOCK (key-simbol) on the RC for 5s with the VCR switched on. Philips VR220/58 VCR Modulator on/off Without cassette. Press and hold STOP on the RC and then press STOP/EJECT on VCR. Select the line 'MODULATOR' on the TV screen or 'MOD+' in the display with P+/-. In the display select 'OFF' / 'MOD-' (modulator off) with VOLor 'MOD+' (modulator on). Confirm with OK. Exit with MENU Philips VR220/58 VCR Modulator preset Without cassette. Hold the STOP button on the RC. In addition press the STOP/EJECT button on the VCR until the pre-set modulator frequency appears in the display, e.g. 'M591' (591MHz or 36 ch. UHF). Select line 'OPTIMIZE FREQUENCY' using P+/-. Enter new modulator frequency with the numbers 0-9. In line 'SOUND SYSTEM' select the TV system using VOL+/-. 'G' = PAL B/G. 'K' = SECAM D/K. Confirm with OK. 'STORED' will appear briefly on the screen. Philips VR220/58 VCR Reset to factory settings Disconect from the mains power supply. Press and hold the STANDBY/ON button on the device and reconnect to the mains power supply.  Release the button when 'OSD' appears in the VCR display. Philips VR400/58 VCR Auto ST-BY off Press and hold STOP till symbol appears. Philips VR400/58 VCR Modulator off. Without cassette. 
Press and hold SYSTEM till 'G591' appears. Press and hold CLEAR (CL) till  'MOFF' appears. Exit: TV/STANBY. Philips VR400/58 VCR Modulator on.  Without cassette. 
Press and hold SYSTEM till 'MOFF' appears. Press and hold CLEAR (CL) till 'G591' appears. Exit: TV/STANBY. Philips VR400/58 VCR Modulator preset Without cassette. VCR st-by. 
Press and hold SYSTEM till 'G591' appears. System change:
SELECT. Freq. Change: P +/-. Store: OK.
Exit: TV/STANBY.
Revox D -TV C9003 CTV Service Mode
On the local control press function key five times (indication "Service" will appear), afterwards within a sec. press key "MEN" on the remote control. Store: X. Exit: TV.
Saba ULTRACOLOR T55U42 T55U43 T63U42 T63U43 ICC5115ML 110 ICC5116MM 90° CTV Combination Lock Cancel 
Switch off set with main switch. Switch on set with main switch and during doing this press the buttons + and - of volume control on the set's control board simultaneously until the display lights. Display: SS… Press the button 'S' on the RC. Switch off with RC. Now the combination lock is unlocked and one can switch on again in the normal manner.
Saba ICC9 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again. (WARNING: scart must be free.)
Saba T7032VT TX92 CTV Hotel Mode Cancel
Put TV into standby, then turn power off, then turn power on whilst holding standby button on remote and step through menus to `vol set` and increase level to max.
Salora 28N8S 2B-F CTV Service Mode
Quick press: --\-, MENU, TV.
Salora 17/21SF 25/28X71 25/28SP50 STEREO PLUS CTV Service Mode
MUTE --> OK (M) --> TV
Controls: cursor buttons. Store: OK (M).
Exit: T
Samsung CB-14F1 CB-20P30 CB-20H1 CB-20S20 CB-21H1 CB-21P30 CB-21S20 CB-3373
CB-5020 CB-5073 CB-5079 CB-5320 CB-5373 CB-5379 S15A CTV Service Mode
STAND-BY --> DISPLAY --> P.STD --> MUTE --> POWER ON.
Controls: VOL +/-, CH +/-. Exit: POWER OFF.
Samsung CK5038 SCT11B CTV Service Mode
STAND-BY --> P.STD --> HELP --> SLEEP --> POWER ON.
Controls: VOL +/-, CH +/-. Exit: STATUS.
Samsung CX5944 CX6844 SCT12B CTV Service Mode
STAND-BY --> P.STD --> HELP --> SLEEP --> POWER ON.
FACTORY MODE: set PSL=15 and PVA=63.
Controls: VOL +/-, CH +/-. Exit: STATUS
Samsung CB-14V10 CB-3373 CB-14V20 CB-5073 CB-20P30 CB-5079 CB-20S10 CB-5373
CB-20S20 CB-21P30 CB-21S10 CB-21S20 SCT13B CTV Service Mode
STAND-BY --> P.STD --> HELP --> SLEEP --> POWER ON.
Controls: VOL +/-, CH +/-. Exit: STATUS.
Samsung CS7272 SCT51A CTV Service Mode 
PICTURE OFF --> SLEEP --> P.STD --> MUTE --> PICTURE ON
Samsung CS-721 CS-723 SCT52A CTV Service Mode
PICTURE OFF --> SLEEP --> P.STD --> MUTE --> PICTURE ON
Samsung TVP3350 TVP5050 SCV11A SCV11B CTV/VCR Service Mode 
STAND-BY --> P.STD --> MENU --> SLEEP --> POWER ON
Schneider DTV 1 CTV Service Mode
Simultaneous press Service-button on digibord & button C on RC. Selection: Bass +/-.
Adjust: Volume +/-. Store: T. Exit: TV.
Schneider DTV 100 CTV Service Mode
Simultaneous press red & blue buttons on RC then (in 5 sec.) simultaneous press P- & P+ on local keyboard. Commands: arrows.
Store:OK.
Exit: TV.
Schneider DTV 2 CTV Service Mode
Like DTV 1 or simultaneous press Service button (down right on RC) & C button on RC.
Selection: Bass +/-. Adjust: Volume +/-.
Store: IDEAL.
Exit: TV.
Schneider DTV 3 CTV Service Mode
Simultaneous press red & blue buttons on RC then (in 5 sec.) simultaneous press P- & VOL+ on local keyboard. Selection: wheel.
Adjust: ring. Store: red button. Exit: OFF.
Schneider TV 4 CTV Service Mode
Simultaneous press red & blue buttons on RC then (in 5 sec.) simultaneous press P- & VOL+ on local keyboard. Selection: P +/-.
Adjust: VOL +/-. Store: auto. Exit: OFF.
Schneider STV7128 TV 8 CTV Service Mode
Simultaneous press red & blue buttons on RC then (in 5 sec.) simultaneous press P- & VOL+ on local keyboard. Selection: P +/-.
Adjust: VOL +/-.
Store: auto.
Exit: OFF.
Schneider TV 9 CTV Service Mode
Simultaneous press red & blue buttons on RC then (in 5 sec.) simultaneous press P- & VOL+ on local keyboard. Selection: P +/-.
Adjust: VOL +/-.
Store: auto.
Exit: OFF.
Schneider STV355FST CTV Service Mode
MENU --> SERVICE --> OK --> 089
SEG 11AK18 CTV Service Mode MENU 1 6 7 5
SEG 11AK19 CTV Service Mode MENU 4 7 2 5
Seleco STEREO PLUS CTV Service Mode 
MUTE --> OK (M) --> TV
Controls: cursor buttons. Store: OK (M).
Exit: TV
Sharp 4BSA CTV Service Mode
Short conntacts 2 & 6 on bord TB connector and press button 'MODE' on RC. Remove short.
Store: auto. Exit: 'MODE'.
Sharp 63CS-03S CS CTV Service Mode
Press and hold buttons VOL- and PR+ on the local keyboard and then switch on with main switch. Store: 'POWER'.
Sharp D3000 CTV Service Mode
Press Service-button on Digi-modul. Store: on/off. Exit: Service button.
Sharp Euro-DS1 CTV Service Mode
Short conntact 2 & 6 on Digi Module Service Slot and then press button 'MODE' on RC.
Store: (romb-symbol) on RC. Exit: standby, switch off, switch on, remove short.
Sharp 54AT-15SC CTV Service Mode
Press and hold buttons VOL- and PR+ on the local keyboard and then switch on with main switch.
Store: 'POWER'.
Sharp DV-5401S CTV Service Mode
Locate place for 2 buttons on local keyboard (main board) S754-MODE and S755-PRESET.
Enter: short S754 (-SERV-).
Commands: CH +/-. Store: short S755.
Siemens FS369M4 CS9409 CTV Service Mode 
Info Center' --> 'Special Functions' --> 'Service' --> Code Number 089
Siemens SAT Program
Lock Unlock: Press key-symbol and 6 1 0 1.
Silva STV355FST CTV Service Mode 
MENU --> SERVICE --> OK --> 089
Sony KV-E2531 KV-E2931 KV-E3431 AE-2 CTV Service Mode
Turn on the main power switch of the set while pressing any two buttons on the front panel.  'TT' will appear on the upper right corner of the screen. Press the 'MENU' button on the RC.
In menu select 'DEMO' and press 'OK'. Select DEVICE corresponding to the adjustment you need. Store: OK. Exit: turn off.
Sony KV-2170 KV-2180 KV-2540 BE4 CTV Service Mode ? --> 5 --> VOL+ --> TV --> MENU
Exit: 00
Sony KV-B2911 CTV Service Mode
Turn on the main power switch of the set while pressing any two buttons on the front panel. 'TT' will appear on the upper right corner of the screen. Press the 'MENU' button on the RC.
In menu select 'DEMO' and press 'OK'. Select DEVICE corresponding to the adjustment you need.
Store: OK.
Exit: turn off.
Sony KV-G21M1 CTV Service Mode Switch TV to STANDBY.
DISPLAY --> 5 --> VOL+ --> POWER
Telefunken ICC9 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again. (WARNING: scart must be free.)
Telefunken STEREO PLUS CTV Service Mode
MUTE --> OK (M) --> TV
Controls: cursor buttons. Store: OK (M).
Exit: TV
Telefunken TX-90 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again.
Telefunken TX-91 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again.
Thomson ICC19 CTV Service Mode
Switch to Standby. Switch off with the mains switch. Press and hold blue button and then switch on with the mains switch. Press blue button again. Exit: switch off with mains switch.
Thomson ICC19 CTV Service Mode
Switch to Standby. Switch off with the mains switch. Press and hold 'PROG-' and 'VOL-' and then switch on with the mains switch. Exit: switch off with mains switch.
Thomson ICC9 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch.  Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again. (WARNING: scart must be free.)
Thomson TX-90 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off.  Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again.
Thomson TX-91 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again.
Toshiba 2150 S5E CTV Service Mode
Press 'MUTE' button. Press and hold 'MUTE' button and press 'MENU' on local keyboard.
Select: PR nr.. Adjust: VOL+/-. Store: auto.
Exit: 'STANDBY'. Test picture: 'AV'.
Toshiba 2876DD
2988DG CTV Service Mode
Press 'MUTE' button. Press and hold 'MUTE' button and press 'MENU' on local keyboard.
Select: PR+/-. Adjust: VOL+/-. Store: auto.
Exit: 'STANDBY'. Test picture: 'AV'.
Universum 6000 CTV Service Mode
Switch on with main switch. Press 'MENU', 'TV', 'i'. If TV is still in st-by press 2x'TV', 'i'.
Select and adjust with cursors. Store: 'OK'.
Exit: switch off with main switch.

Monday, 25 February 2019

THOMSON - 20LCDB03B - TELEFUNKEN - SABA_FERGUSON - BRANDT - SERVICE MODE


THOMSON - 20LCDB03B - TELEFUNKEN - SABA _ FERGUSON - BRANDT - SERVICE MODE


APPLICABLE TO - THOMSON - 20LCD B3B - TELEFUNKEN  - SABA - FERGUSON - BRANDT TVs

ENTERING SERVICE MODE {supports 15", 20" and 20" bi-sonic.}

  • Press the "Menu" button and the screen will appear.  "Overview" below as Figure Overview OSD.
  • Press "Info" button and "1", "0" and "3" buttons step by step to enter Service Mode.  Service mode will appear on the screen.
  1. Color Temp:  P-N means 'Normal' on Ypbpr1, V-N means 'Normal' on video mode.  Each item decide different gamma curve.  
  2. Red drive, Green drive and Blue drive, means gamma RGB gain control by scaler.
  3. Red-offset, Green-offset and Blue-offset means gamma RGB offset.
  4. Reset to Default => Press "OK" button will load all default value on user OSD.
  5. Calibration => Press this both guide to calibrate A/D converter, white/black level on PC input.  Also guide to calibrate A/D converter Pb,Pr offset on YpbPr input.  
  6. Auto turn on => Toggle On/Off control auto turn On.  This function for factory burn-in sets.  Only active on selection PC input then main power Off.
  7. Green lable => Tuner S/W version, time when compiling S/W model name, main S/W version.
  8. OSD position => OS Didplay posistion selection.
  9. Factory Save => Press 'OK' to save all parameters on service mode.
  10. Auto Adjustment => Auto adjustment new timing (Position, Phase etc).  Only active on PC mode.
  11. Video int Gain => This slider bar used to align brightness spec: of video mode.  larger value bring to brighter.  Control by video decoder VPV3230.
  12. Color => Adjust color saturation.  Same function on User OSD.  Control by video.
  13. Tuner set V-Level => not used.
  14. Tuner Get V-Level => not used.
  15. Set First Installation => Enable means TV will pop-up installation OSD at next Power On.
  16. Tuner Set Factory Programs => not used.
  17. Exit =. To Exit from Service Mode.
  18. PW Gamma => Gamma curve selection.  'Automatic' means, pick up proper gamma curve automatically when user choose Normal, Warm and Cool. Value change is not recommended.
  19. Scale Mode => Screen ratio selection.
  20. VPC AGC On => Turn On video decoder "Auto gain control" {Analog input leve adjustment}
  21. VPC AGC Off => Turn OFF Video decoder "Auto gain control".
  22. HV Lock sensitivity => Tuner HV sync sensitivity.  Value chang not recommended. Fake program be detected or Real Program be skipped.
  23. Color Delay => Color timing delay, which only impact on video mode.  For development only.  Value change not recommended. 
  24. Audio gain => not used.
  25. Pb offset => Adjust Pb offset on YpbPr input.
  26. Pr offset => Adjust Pr offset on YpbPr input.
  27. Enter PW 1230 adjustment page => De interlacer parameters control.  For development only.  Value change is not recommended.
  28. Video Format => Select video standard.  Force to 'Auto'.
  29. Default language => Set default language.  Same function on user OSD.
  30. RGB filter => Sharpness filter for PC port of scaler.  Impact on PC and YpbPr input.
  31. Video filter => Sharpness filter of video of scaaler.   Impact on TV Video and YcbCr.
  32. Monitor sync => Force to "On". So that video format can auto detection.
  33. Reset all NVRAM => Press "OK" will reset all parameters is on service mode, including color temperature settings, brightness settings...etc.
  34. Test pattern => Display test pattern which generate by scaler. Only active on PC source. 
  35. H.Position => Adjust Horizontal Position when PC source in.
  36. V.Position =>Adjust Vertical Position while PC source in.
  37. Left Time => Left time means the time added by standby + TV On.  The right item display the time of TV-On only.
  38. Project code => As title.
  39. Panel resolution => As title.
  40. NvRam ver => display EEPROM data version.
  41. HVX Res/Hfreq => Timing information.  Resolution and H clock.
  42. HXV Total => Timing information.
  43. Mode Num => Timing information. Sequence of timing chart.
  44. DCLK => Timing information Data Clock.  These 4{41,42,43 & 44} items above are for development check only.  
  45. Factory Save => Saves factory parameters.
  46. Green Label => Display tuner S/W version

Tuesday, 12 February 2019

BRANDT FERGUSON SABA TELEFUNKEN THOMSON POWER SUPPLY DESCRIPTIONS 50HZ - 100HZ CHASSIS USING TEA 2261 IC AS POWER CONTROL WORKING PRINCIPLES.

  BRANDT FERGUSON SABA TELEFUNKEN THOMSON POWER SUPPLY   DESCRIPTIONS   50HZ - 100HZ CHASSIS USING TEA 2261 IC AS POWER CONTROL   WORKING PRINCIPLES. 



50Hz CHASSIS



100Hz CHASSIS






GENERATION OF INTERNAL REFERENCES AND POWER SUPPLIES

                            The power supply at Pin 16 comes from:

     On start-up, half-wave rectification of the mains by the mesh RP025, CP054, and a diode of the bridge rectifier. In Standby Mode, winding 9, 8 of LP020 (fly-back mode). 12 V obtained by rectification (DP050, CP054) is applied to regulator IP050 (7809 applied to Diode DP051), which supplies 9 V via DP052.  In Steady-State, winding 9, 10 of LP020 (fly-back mode). Rectification by DP053 supplies a voltage of about 11 V. 

     Note that in this case Diode DP052 is blocked, and disconnects circuit IP02.
Resistor RP054 delivers the power supply to the final stage (Pin 15), and sets its maximum current.  The circuit supplies several voltages and service signals according to changes in the direct current voltage at Pin 16.  As soon as +Vdc reaches approximately 4V5, an internal reference of +2V5 is generated. For +Vdc & 5V5, a RESET pulse is produced.  When +Vdc reaches 10V3 (Vdc start), enabling of an internal power supply Vdc int = 5 V. This stabilized voltage allows the circuit to perform well in a wide voltage range on Pin 16.  This threshold also triggers the passage to high state of Vdc off, thus enabling the interlock and limit management logic, and authorising pulse output from Pin 14 (as long as +Vdc remains higher than +Vdc stop, i.e. 7V4 typ.).  For Vdc of 15V7 typ., passage to high state of Vdc max, and interlocking of the circuit by the interlock and limit management logic.

OPTIONS

SWITCHING OF START-UP POWER SUPPLY:

     On 100-Hz chassis, a thyristor (TP025) is added in series with Resistor RP025.  When mains power is applied, a current from the 300 V via the RP028, RP030 through 32 resistor network energizes the thyristor. The thyristor then channels the CP054 charging current.  When the power supply starts up, a voltage of 9V6 appears at the output of Regulator IP050 and saturates Transistor TP026. With its gate then earthed, the thyristor de-energizes the next time the mains alternation is inverted.  This layout reduces the consumption by 0.7W.

LOW-POWER SWITCH

     A low-power switch can be connected in series with Resistor RP025 to replace the classic mains switch.  In operation, this switch connects RP025 via Resistor RP55 to Pin 16 of IP60.  In Off position, this switch switches Pin 16 of IP060 to earth via Resistor RP035 and Diode DP035.  Zener Diode DP054 limits the voltage to the terminals of CP54 when Off.


OUTPUT STAGE

     The output stage of the TEA2261 consists of a push-pull.  It supplies the basic current for control of TP060, and then channels the reverse locking current caused by the discharging of CP040.  In the conduction phase, Resistor RP054 limits the polarization current.  TP060 SWITCHING CIRCUITS resistors RP029 through RP032 pre-charge CP040 as soon as power is switched on, to ensure an adequate reverse locking current during the start-up phase and at the beginning of each burst. Self-induction coil LP040 sets the dl/dt of the control current reversal.  The circuit DP022, CP023, RP022 slows the rise in collector voltage of TP060 when it is blocked, to ensure minimum dissipation through switching, and to limit the overvoltage peak. To do this, it is assisted by the secondary assembly DP113, LP112, RP112, CP112, and DP112.

Secondary Voltages

The secondary wingdings produce five direct voltages:

     +USYS which can be between 127 and 140 volts, according to chassis, and according to the winding connector selected (19 through 22 via jumpers JP914 through 917).

     +US and -US, symmetric power supplies with specific earth distributed to the audio stage via a cable (from BP120).  +UVERT, vertical stage power supply voltage. Also applied to the regulator circuit, IP30, and causes the polarization of the base of TV002 (IV001 power supply).  +U7V, voltage supplying the switched 5 V.  In Standby Mode, the 10VSTBY is produced by Regulator IP130 and Diode DP133. In Steady State, the 13 V from the EHT takes over via Diode DP134.  The switched 5 V is obtained at Pin 8 of IP140 (switched by voltage +U13, Pin 4) on 50-Hz stereo chassis, while a transistor, TP146, handles this regulation task for 50-Hz Dolby and 100-Hz chassis.

Secondary Regulation

     This mode is adopted as soon as Steady-State Mode begins. It regulates voltage USYS.  A fraction of USYS, tapped off by divider bridge RL082, RL081, and RL080,
is applied to Pin 31 of IV001 (SMPS IN).  This information is compared to an internal reference whose value can be adjusted according to operating mode (USYS adjusted in 64 steps within a 16-V range).  A strobe signal at line frequency with a variable duty cycle is available on Pin 37 (SMPS OUT).  This signal is applied to galvanic isolating transformer LP070 via Transistor TP161.  A soft start circuit is associated with the production of the command strobe signal. (CV246, Pin 17; when power is applied to circuit IV001, it is charged to 5V5 in 900 ms. The network RV242, CV242, CV243 limits the pass band of the entire regulating loop to 300 Hz.  On 100-Hz chassis, Transistor TP162 controls transformer degassing   In the event of irregularities on the secondaries or in the time bases, the interlock circuit forces the BREATHING line to low state (Pin 28 of IV001).  The regulating and time base commands are then stopped. If the error persists after two more start-up attempts by IV001, the TV goes into Standby Mode.

Power Supply Interlocks

     Overloads and short circuits are detected by analysing the primary current in the emitter resistor of TP060 (input at Pin 3 of circuit IP060).  The sensitivity of this stage was increased in Standby Mode to detect errors in the low-voltage secondaries (RP065, TP027, and RP059). For this reason, when an incident occurs in Steady State on a secondary other than U SYS, it is necessary to go to Standby Mode to trigger the interlock.  
  •  An overload or short circuit on voltages +U VERT or +10 V STBY leads to:


power supply VCC1 of the regulation and sweep circuit (IV001) disappearing.  
 An overload or short circuit on +US causes TP190 and TP170 to conduct.  This forces the breathing interlock input of the regulation and sweep circuit (IV001) to be triggered by a low level.  
  •  An overload or short circuit on: 
  • US causes DP190 and TP170 to conduct, and triggers the IV001 interlock.  In the event that external speakers with too low an impedance value are connected (Dolby versions), or when incidents occur on the +5 V, simply shut off the sweep to remove the overload:


·         Excessive current in Resistor RP130 causes TP129 and TP170 to conduct, and triggers the IV001 interlock (audio mute).
·         A short circuit on the +5 V blocks TP175 through the action of DP178, and causes TP170 to conduct (see sweep interlocks), causing the IV001 interlock
             to trigger and the +13 V to disappear.


Detection of Mains Power Failure

     In the event of mains power failure, the micro controller must be informed promptly so that the data in the NVM (IR003) can be saved, and to avoid a plop in the speakers (sound mute).
    To do this, POWER FAIL has a rising edge in the event of mains power failure in ON Mode, and a falling edge in the event of mains power failure in Standby Mode.
    The signal is received by the management circuit via the INTERRUPTION input at Pin 55. Transistor TR091 produces a low mute level when the phenomenon occurs in ON Mode.
    The negative voltage rectified in Forward Mode by Diodes DP151/152 is an image of the mains voltage. It blocks TP152 in ON Mode. TP150 and TP145 are blocked. TP167 is saturated, and the POWER FAIL line has a low level.

     When the mains falls below 160 Vac, TP152, TP150, and TP145 conduct, TP167 generates a rising edge on the POWER FAIL line by blocking off.  In Standby Mode, because voltage +UVERT goes from 23-26 V to 14 V, the RP150/151 network saturates TP150, TP145 conducts and blocks TP167, and the POWER FAIL line has a high level.
When mains power breaks down, the decrease in 10VSTBY saturates TP166 and TP167, and the POWER FAIL line has a falling edge.

Wednesday, 6 February 2019

HOW TO ENTER SERVICE MODE TO TVS – SABA, TOSHIBA, SHARP, SAMSUNG, TELEFUNKEN, FINLUX, DIGIVISION

How to enter Service Mode to TVs – Saba, Toshiba, Sharp, Samsung, Telefunken, Finlux, Digivision ITT

Universum, Thomson, Saba, Telefunken, Siemens, Silva, Sharp, Schneider and more……
Akai CT-2119 CTV Test Mode Simultaneous press [+] & [-] on local panel and then power on with main switch. Exit: POWER. Allstar 3750 CTV Hotel Mode OFF: Select program 38. Simultaneous press (3 sec) STORE & CONTROL+ on local keyboard. ON: Select program 38. Simultaneous press (3 sec) STORE & PROGRAM- on local keyboard. AudioTon CTV 5502 10.3 90° MONO CTV  Child Lock Clear Press UP & DOWN buttons together on TV's local control and then switch on. You will see  SERVICE MODE.  Do not press any button, just power off the set, then on. The child lock will be cleared. AudioTon CTV 5502 10.3 90° MONO CTV Service Mode  Press UP & DOWN buttons together on TV's local control and then switch on. Beko CTV Service Mode  Simultaneous press P+ & P- on local panel and then power on with main switch. Blaupunkt MM63-13VT FM240.00 CTV ATS Press button P/C on RC and switch on TV with main switch. Blaupunkt MM63-13VT FM240.00 CTV Hotel Mode Cancel Press button 'i' on RC and switch on TV with main switch. Brandt ICC9 CTV Service Mode Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off.  Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again. (WARNING: SCART should be free.) Continental CT1412B CTV Service Mode  Press and hold P+ and P- on local panel, then switch on TV with main switch. Ferguson ICC9 CTV Service Mode Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again. (WARNING: SCART should be free.) Ferguson TX92 CTV Hotel Mode Cancel Put TV into standby, then turn power off, then turn power on whilst holding standby button on remote and step through menus to `vol set` and increase level to max.
Finlux 17/21B60 63/71Y2 STEREO PLUS CTV Service Mode MUTE --> OK (M) --> TV Controls: cursor buttons. Store: OK (M). Exit: TV GoldStar MC-51B CTV Service Mode Simultaneously Press MENU, VOL-, PR- on the local panel. Digivision DIGI III 110° CTV Service Mode Turn on 'TV Internal Service Program' switch on the digital module (SE on display). On RC:  1=U1 V SHIFT, 2=U2 V LIN DN, 3=U3 V LIN, 4=H1 H SHIFT, 5=H2 H AMP, 6=H3 EW AMP, 7= C, 8=C1, 9=C2, 0=H4 EW TRAPEZ… TV=MEMO, VOL+/-=ADJUST. ITT STEREO PLUS CTV Service Mode MUTE --> OK (M) --> TV Controls: cursor buttons. Store: OK (M). Exit: TV LG MC64 CTV Service Mode  Simultaneous press OK on RC & local panel. LG MC84 CTV Service Mode  Simultaneous press OK on RC & local panel. Loewe. Art.-Nr. 64420 66426 66449 66450 66460 66480 66490 C9000 CTV TV Service Mode Simultaneous press CM on the RC & "Service" key on the control panel. Select: MEM IN/OUT. Adjust: VOL +/-. Store: X. Exit: TV. Loewe. Art.-Nr. 64420 66426 66449 66450 66460 66480 66490 C9000 CTV VT Service Mode Simultaneous press VT on the RC & "Service" key on the control panel. Select: MEM IN/OUT. Adjust: VOL +/-. Store: X. Exit: TV. Loewe. C9003 CTV Service Mode On the local control press function key five times (indication "Service" will appear), afterwards within a sec. press key "MEN" on the remote control. Store: X.  Exit: TV. Loewe. Q2200 CTV Service Mode Go to 'SERVICE' in menu and then quick press 'MENU' on the RC.  Select: yellow cursors. Adjust: +/-. Store: 'X'. Exit: 'TV'. Luxor 5585-21A1 7057-27 63/7954 STEREO PLUS CTV Service Mode MUTE --> OK (M) --> TV Controls: cursor buttons. Store: OK (M). Exit: TV Mitsubishi CT21M5E CTV Service Mode  Press S701 (on board) and button 9 (in 5s). Store: '0'. Exit: stand-by. NEC XExx XPxx XVxx MON Service Mode Select DISPLAY MODE. Press PROCEED. Press and hold RESET. Then simultaneous press + & -. 'Warning Entering Service Menu…' appears.  Press PROCEED for enter. Be careful Nokia 6364, 7364 2B-F CTV Service Mode  Quick press: --\-, MENU, TV. Nokia EUROSTEREO CTV Service Mode In 1s press buttons '-/--', 'MENU', 'TV'. Select: PR+/-. Adjust: VOL+/-. Store: fill-dot-symbol on RC (near 'i' button).  Exit: 'STANDBY'. Nokia 63/7168 55A1-0 45H1-0 55Y2-0 63/7157 63/7177 STEREO PLUS CTV Service Mode MUTE --> OK (M) --> TV Controls: cursor buttons. Store: OK (M). Exit: TV Nokia STEREO PLUS CTV Service Mode i --> M --> PROGR. Controls: cursor buttons. Store: M. Exit: TV Nordmende DC1 CTV Service Mode Switch to Standby. Switch off with the mains switch. Press and hold red button on RC and then switch on with the mains switch (cca 10s). Select: numbers buttons. Adjust: +/-. Store: red button. Exit: 'MUTE'. Nordmende DC2 CTV Service Mode Switch to Standby. Switch off with the mains switch. Press and hold red button on RC and then switch on with the mains switch (cca 10s). Select: numbers buttons. Adjust: +/-. Store: red button. Exit: 'MUTE'. Nordmende Color 3038 F15-03 110° CTV MDA2061 Replacement After replacement of the MDA2061 (IR73) the TV receiver acts as folows:  a) All program storage have stored Ch00.  b) The indicator shows German function characters.  c) PAL and SECAM EAST standard reception is possible (not NTSC and/or SECAM WEST). If required to change according to paragraph. b and c then switch off the set by the mains switch. Press both buttons + and - for volume on TV and simultaneously switch the set on with the mains switch. Keep the two volume buttons pressed until the display indicates Pr. after 8s the display indicates __. Now the following buttons can be pressed on the RC, thus additional corresponding segments will be illuminated: Button '1' function symbols indicate international display. Reversible to German display with button '2'. Button '5' additional SECAM WEST and/or NTSC reception (Multistandard). Reversible to Single Standard with button '3'.  Store: Stand-By. Nordmende ICC10 CTV Service Mode Switch to Stand By. Switch off with the mains switch. Press and hold 'VT' on RC then switch on with the mains switch. Nordmende ICC9 CTV Service Mode Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press blue button on RC and switch on TV with main switch. Press blue button again. (WARNING: scart must be free.) Palladium TV-100 CTV Service Mode Simultaneous press red & blue buttons on RC then (in 5 sec.) simultaneously press P- & P+ on local keyboard. Commands: arrows.  Store: OK.  Exit: TV. Panasonic EURO-1 CTV Service Mode In Sound-Menu Low-tone-regel to MAX and High-tone-regel to MIN. Press VOL- on TV and RESET on RC in some time.  Select: red and green buttons.  Adjust: yellow and blue buttons.  Store: 'STORE'. Exit: switch off. Panasonic EURO-2 CTV Service Mode In Sound-Menu Low-tone-regel to MAX and High-tone-regel to MIN. Press 'F' button on TV.  Then press VOL- on TV and REVEAL on RC in some time. Select: red and green buttons. Adjust: yellow and blue buttons. Store: 'STR'. Exit: 'N' on RC. Panasonic MX-3 MX-3C CTV Hotel Mode ON: Press simultaneously 'OFF TIMER' on RC and 'CH.UP' local. OFF: Press simultaneously 'OFF TIMER' on RC and 'VOL-' local. Panasonic MX-3 MX-3C CTV Service Mode Simultaneously press 'RECALL' on RC and 'VOL-' local. Exit: 'NORMAL' on RC. Philips ANUBIS B CTV Hotel Mode ON: Set HOTEL ON in Service Menu. Select programm 38. Simultaneous press (3 sec) INSTALL & P- on local keyboard. OFF: Set HOTEL OFF in Service Menu. Philips ANUBIS B CTV Service Mode  Simultaneously press VOL+ & P- on RC. Exit: STANDBY. Philips Anubis S CTV Hotel Mode OFF: Select program 38. Simultaneous press (3 sec) PR+ & VOL- on local keyboard. ON: Select program 38. Simultaneous press (3 sec) STORE & PR- on local keyboard. Philips L7.1A CTV Service Mode  With special service RC. Or short M25, M25 on board and then switch on TV. Exit: st-by. Philips L9.1 CTV Hotel Mode Select program 38 on the TV. Simultaneously press the keys VOLUME- and VOLUME+ on the keyboard of the TV and the OSD key of the remote control. Philips L9H CTV Service Mode This model also supports the 062596 sequence followed by [MENU] (service default) or [i+]/[OSD] (service mode). Philips MD1.2E CTV Service Mode There is a small Service jumper to short on the small signal PCB. When the TV is in this first level service mode, you can go in the second level service mode by pressing both MENU and - keys on top of the TV at the same time. There you can read much parameters and proceed with most of the adjustments. In fact this method let you use an ordinary Remote control but you also need to open the back cover. With the special service remote control, a special code is sent to enter the service mode. Philips MG3.1E CTV Service Mode Option 1: In the TV-set itself is a 3-pin connector with which either SERVICE-DEFAULT or SERVICE-MODE can be activated. This connector is depicted 0356 (SERVICE-PINS) on page K7 (TXT&CONTROL).  Shorting pins 1-2 will activate SERVICE-MODE. Shorting pins 2-3 will activate SERVICE-DEFAULT.  Option 2: Activate these modes using the remote control. Obviously option 2 is the preferred method because the settings have to be changed using a remote control anyway.... To activate SERVICE-DEFAULT: Press 0 6 2 5 9 6 and then the [menu] button. The message ‘Service Default’ appears and channel ‘SER T’ will be selected. This only sets some settings to a preset value (color/brightness/volume and such). This mode is primarily intended to be used when the non volatile memory has been replaced. It is then loaded with the default values. To activate SERVICE-MODE: Press 0 6 2 5 9 6 and then the [i+] button. After pressing 0 6 2 5 9 6 the message ‘Dealer’ should have appeared. Do not worry about the channel changing while you press the numbers.  Service technicians have the means of entering service mode using a special remote control. Philips 29PT9416 MG7.1 CTV Service Mode Use the standard remote control an key in a special sequence 0 6 2 5 9 6 followed by pressing the 'MENU' button. If the main menu also appears with the service menu just press 'MENU' again to clear it. The other way is to short the two service pins on the signal panel (pins 2 and 3 of connector 0356). The advantage of this last method is that all the software protections are turned off. Philips Y6 CTV Service Mode Use the standard remote control an key in a special sequence 0 6 2 5 9 6 followed by pressing the 'MENU' button. If the main menu also appears with the service menu just press 'MENU' again to clear it. Philips VR210/58 VCR Modulator off Without cassette. Press and hold SYSTEM till 'G591' appears. Press and hold CLEAR (CL) till 'MOFF' appears. Exit: TV/STANBY. Philips VR210/58 VCR Modulator on Without cassette. Press and hold SYSTEM till 'MOFF' appears. Press and hold CLEAR (CL) till 'G591' appears. Exit: TV/STANBY. Philips VR220/58 VCR Child Lock Cancel Press CHILD LOCK (key-simbol) on the RC for 5s with the VCR switched on. Philips VR220/58 VCR Modulator on/off Without cassette. Press and hold STOP on the RC and then press STOP/EJECT on VCR. Select the line 'MODULATOR' on the TV screen or 'MOD+' in the display with P+/-. In the display select 'OFF' / 'MOD-' (modulator off) with VOLor 'MOD+' (modulator on). Confirm with OK. Exit with MENU Philips VR220/58 VCR Modulator preset Without cassette. Hold the STOP button on the RC. In addition press the STOP/EJECT button on the VCR until the pre-set modulator frequency appears in the display, e.g. 'M591' (591MHz or 36 ch. UHF). Select line 'OPTIMIZE FREQUENCY' using P+/-. Enter new modulator frequency with the numbers 0-9. In line 'SOUND SYSTEM' select the TV system using VOL+/-. 'G' = PAL B/G. 'K' = SECAM D/K. Confirm with OK. 'STORED' will appear briefly on the screen. Philips VR220/58 VCR Reset to factory settings Disconect from the mains power supply. Press and hold the STANDBY/ON button on the device and reconnect to the mains power supply.  Release the button when 'OSD' appears in the VCR display. Philips VR400/58 VCR Auto ST-BY off Press and hold STOP till symbol appears. Philips VR400/58 VCR Modulator off. Without cassette. 
Press and hold SYSTEM till 'G591' appears. Press and hold CLEAR (CL) till  'MOFF' appears. Exit: TV/STANBY. Philips VR400/58 VCR Modulator on.  Without cassette. 
Press and hold SYSTEM till 'MOFF' appears. Press and hold CLEAR (CL) till 'G591' appears. Exit: TV/STANBY. Philips VR400/58 VCR Modulator preset Without cassette. VCR st-by. 
Press and hold SYSTEM till 'G591' appears. System change:
SELECT. Freq. Change: P +/-. Store: OK.
Exit: TV/STANBY.
Revox D -TV C9003 CTV Service Mode
On the local control press function key five times (indication "Service" will appear), afterwards within a sec. press key "MEN" on the remote control. Store: X. Exit: TV.
Saba ULTRACOLOR T55U42 T55U43 T63U42 T63U43 ICC5115ML 110 ICC5116MM 90° CTV Combination Lock Cancel 
Switch off set with main switch. Switch on set with main switch and during doing this press the buttons + and - of volume control on the set's control board simultaneously until the display lights. Display: SS… Press the button 'S' on the RC. Switch off with RC. Now the combination lock is unlocked and one can switch on again in the normal manner.
Saba ICC9 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again. (WARNING: scart must be free.)
Saba T7032VT TX92 CTV Hotel Mode Cancel
Put TV into standby, then turn power off, then turn power on whilst holding standby button on remote and step through menus to `vol set` and increase level to max.
Salora 28N8S 2B-F CTV Service Mode
Quick press: --\-, MENU, TV.
Salora 17/21SF 25/28X71 25/28SP50 STEREO PLUS CTV Service Mode
MUTE --> OK (M) --> TV
Controls: cursor buttons. Store: OK (M).
Exit: T
Samsung CB-14F1 CB-20P30 CB-20H1 CB-20S20 CB-21H1 CB-21P30 CB-21S20 CB-3373
CB-5020 CB-5073 CB-5079 CB-5320 CB-5373 CB-5379 S15A CTV Service Mode
STAND-BY --> DISPLAY --> P.STD --> MUTE --> POWER ON.
Controls: VOL +/-, CH +/-. Exit: POWER OFF.
Samsung CK5038 SCT11B CTV Service Mode
STAND-BY --> P.STD --> HELP --> SLEEP --> POWER ON.
Controls: VOL +/-, CH +/-. Exit: STATUS.
Samsung CX5944 CX6844 SCT12B CTV Service Mode
STAND-BY --> P.STD --> HELP --> SLEEP --> POWER ON.
FACTORY MODE: set PSL=15 and PVA=63.
Controls: VOL +/-, CH +/-. Exit: STATUS
Samsung CB-14V10 CB-3373 CB-14V20 CB-5073 CB-20P30 CB-5079 CB-20S10 CB-5373
CB-20S20 CB-21P30 CB-21S10 CB-21S20 SCT13B CTV Service Mode
STAND-BY --> P.STD --> HELP --> SLEEP --> POWER ON.
Controls: VOL +/-, CH +/-. Exit: STATUS.
Samsung CS7272 SCT51A CTV Service Mode 
PICTURE OFF --> SLEEP --> P.STD --> MUTE --> PICTURE ON
Samsung CS-721 CS-723 SCT52A CTV Service Mode
PICTURE OFF --> SLEEP --> P.STD --> MUTE --> PICTURE ON
Samsung TVP3350 TVP5050 SCV11A SCV11B CTV/VCR Service Mode 
STAND-BY --> P.STD --> MENU --> SLEEP --> POWER ON
Schneider DTV 1 CTV Service Mode
Simultaneous press Service-button on digibord & button C on RC. Selection: Bass +/-.
Adjust: Volume +/-. Store: T. Exit: TV.
Schneider DTV 100 CTV Service Mode
Simultaneous press red & blue buttons on RC then (in 5 sec.) simultaneous press P- & P+ on local keyboard. Commands: arrows.
Store:OK.
Exit: TV.
Schneider DTV 2 CTV Service Mode
Like DTV 1 or simultaneous press Service button (down right on RC) & C button on RC.
Selection: Bass +/-. Adjust: Volume +/-.
Store: IDEAL.
Exit: TV.
Schneider DTV 3 CTV Service Mode
Simultaneous press red & blue buttons on RC then (in 5 sec.) simultaneous press P- & VOL+ on local keyboard. Selection: wheel.
Adjust: ring. Store: red button. Exit: OFF.
Schneider TV 4 CTV Service Mode
Simultaneous press red & blue buttons on RC then (in 5 sec.) simultaneous press P- & VOL+ on local keyboard. Selection: P +/-.
Adjust: VOL +/-. Store: auto. Exit: OFF.
Schneider STV7128 TV 8 CTV Service Mode
Simultaneous press red & blue buttons on RC then (in 5 sec.) simultaneous press P- & VOL+ on local keyboard. Selection: P +/-.
Adjust: VOL +/-.
Store: auto.
Exit: OFF.
Schneider TV 9 CTV Service Mode
Simultaneous press red & blue buttons on RC then (in 5 sec.) simultaneous press P- & VOL+ on local keyboard. Selection: P +/-.
Adjust: VOL +/-.
Store: auto.
Exit: OFF.
Schneider STV355FST CTV Service Mode
MENU --> SERVICE --> OK --> 089
SEG 11AK18 CTV Service Mode MENU 1 6 7 5
SEG 11AK19 CTV Service Mode MENU 4 7 2 5
Seleco STEREO PLUS CTV Service Mode 
MUTE --> OK (M) --> TV
Controls: cursor buttons. Store: OK (M).
Exit: TV
Sharp 4BSA CTV Service Mode
Short conntacts 2 & 6 on bord TB connector and press button 'MODE' on RC. Remove short.
Store: auto. Exit: 'MODE'.
Sharp 63CS-03S CS CTV Service Mode
Press and hold buttons VOL- and PR+ on the local keyboard and then switch on with main switch. Store: 'POWER'.
Sharp D3000 CTV Service Mode
Press Service-button on Digi-modul. Store: on/off. Exit: Service button.
Sharp Euro-DS1 CTV Service Mode
Short conntact 2 & 6 on Digi Module Service Slot and then press button 'MODE' on RC.
Store: (romb-symbol) on RC. Exit: standby, switch off, switch on, remove short.
Sharp 54AT-15SC CTV Service Mode
Press and hold buttons VOL- and PR+ on the local keyboard and then switch on with main switch.
Store: 'POWER'.
Sharp DV-5401S CTV Service Mode
Locate place for 2 buttons on local keyboard (main board) S754-MODE and S755-PRESET.
Enter: short S754 (-SERV-).
Commands: CH +/-. Store: short S755.
Siemens FS369M4 CS9409 CTV Service Mode 
Info Center' --> 'Special Functions' --> 'Service' --> Code Number 089
Siemens SAT Program
Lock Unlock: Press key-symbol and 6 1 0 1.
Silva STV355FST CTV Service Mode 
MENU --> SERVICE --> OK --> 089
Sony KV-E2531 KV-E2931 KV-E3431 AE-2 CTV Service Mode
Turn on the main power switch of the set while pressing any two buttons on the front panel.  'TT' will appear on the upper right corner of the screen. Press the 'MENU' button on the RC.
In menu select 'DEMO' and press 'OK'. Select DEVICE corresponding to the adjustment you need. Store: OK. Exit: turn off.
Sony KV-2170 KV-2180 KV-2540 BE4 CTV Service Mode ? --> 5 --> VOL+ --> TV --> MENU
Exit: 00
Sony KV-B2911 CTV Service Mode
Turn on the main power switch of the set while pressing any two buttons on the front panel. 'TT' will appear on the upper right corner of the screen. Press the 'MENU' button on the RC.
In menu select 'DEMO' and press 'OK'. Select DEVICE corresponding to the adjustment you need.
Store: OK.
Exit: turn off.
Sony KV-G21M1 CTV Service Mode Switch TV to STANDBY.
DISPLAY --> 5 --> VOL+ --> POWER
Telefunken ICC9 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again. (WARNING: scart must be free.)
Telefunken STEREO PLUS CTV Service Mode
MUTE --> OK (M) --> TV
Controls: cursor buttons. Store: OK (M).
Exit: TV
Telefunken TX-90 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again.
Telefunken TX-91 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again.
Thomson ICC19 CTV Service Mode
Switch to Standby. Switch off with the mains switch. Press and hold blue button and then switch on with the mains switch. Press blue button again. Exit: switch off with mains switch.
Thomson ICC19 CTV Service Mode
Switch to Standby. Switch off with the mains switch. Press and hold 'PROG-' and 'VOL-' and then switch on with the mains switch. Exit: switch off with mains switch.
Thomson ICC9 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch.  Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again. (WARNING: scart must be free.)
Thomson TX-90 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off.  Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again.
Thomson TX-91 CTV Service Mode
Switch off TV with RC (st-by). Switch off TV with main switch. Wait a few sec till ST_BY LED switch off. Simultaneous press VT button on RC and switch on TV with main switch. Press VT button again.
Toshiba 2150 S5E CTV Service Mode
Press 'MUTE' button. Press and hold 'MUTE' button and press 'MENU' on local keyboard.
Select: PR nr.. Adjust: VOL+/-. Store: auto.
Exit: 'STANDBY'. Test picture: 'AV'.
Toshiba 2876DD
2988DG CTV Service Mode
Press 'MUTE' button. Press and hold 'MUTE' button and press 'MENU' on local keyboard.
Select: PR+/-. Adjust: VOL+/-. Store: auto.
Exit: 'STANDBY'. Test picture: 'AV'.
Universum 6000 CTV Service Mode
Switch on with main switch. Press 'MENU', 'TV', 'i'. If TV is still in st-by press 2x'TV', 'i'.
Select and adjust with cursors. Store: 'OK'.
Exit: switch off with main switch.