REPAIRING AND NOT THROWING AWAY

Richtige Fernseher haben Röhren!

Richtige Fernseher haben Röhren!

In Brief: On this site you will find pictures and technical information about Service Modes, Circuit Diagrams, Firmware Update procedure, Disassemble procedure, Universal remote control set-up codes, Troubleshooting and more....

If you go into the profession, you will obtain or have access to a variety of tech tips databases HERE IT IS Master Electronics Repair !.

These are an excellent investment where the saying: 'time-is-money' rules. However, to learn, you need to develop a general troubleshooting approach - a logical, methodical, method of narrowing down the problem. A tech tip database might suggest: 'Replace C536' for a particular symptom. This is good advice for a specific problem on one model. However, what you really want to understand is why C536 was the cause and how to pinpoint the culprit in general even if you don't have a service manual or schematic and your tech tip database doesn't have an entry for your sick TV or VCR.

While schematics are nice, you won't always have them or be able to justify the purchase for a one-of repair. Therefore, in many cases, some reverse engineering will be necessary. The time will be well spent since even if you don't see another instance of the same model in your entire lifetime, you will have learned something in the process that can be applied to other equipment problems.
As always, when you get stuck, checking out a tech-tips database may quickly identify your problem and solution.In that case, you can greatly simplify your troubleshooting or at least confirm a diagnosis before ordering parts.

Happy repairing!
Today, the West is headed for the abyss. For the ultimate fate of our disposable society is for that society itself to be disposed of. And this will happen sooner, rather than later.

How to use the site:

- If you landed here via any Search Engine, you will get what you searched for and you can search more using the search this blog feature provided by Google. You can visit more posts scrolling the left blog archive of all posts of the month/year,
or you can click on the main photo-page to start from the main page. Doing so it starts from the most recent post to the older post simple clicking on the Older Post button on the bottom of each page after reading , post after post.

You can even visit all posts, time to time, when reaching the bottom end of each page and click on the Older Post button.

- If you arrived here at the main page via bookmark you can visit all the site scrolling the left blog archive of all posts of the month/year pointing were you want , or more simple You can even visit all blog posts, from newer to older, clicking at the end of each bottom page on the Older Post button.
So you can see all the blog/site content surfing all pages in it.

- The search this blog feature provided by Google is a real search engine. If you're pointing particular things it will search IT for you; or you can place a brand name in the search query at your choice and visit all results page by page. It's useful since the content of the site is very large.

Note that if you don't find what you searched for, try it after a period of time; the site is a never ending job !

..............The bitterness of poor quality is remembered long after the sweetness of todays funny gadgets low price has faded from memory........ . . . . . .....
Don't forget the past, the end of the world is upon us! Pretty soon it will all turn to dust!

©2010, 2011, 2012, 2013, 2014 Frank Sharp - You do not have permission to copy photos and words from this blog, and any content may be never used it for auctions or commercial purposes, however feel free to post anything you see here with a courtesy link back, btw a link to the original post here , is mandatory.
All posts are presented here for informative, historical and educative purposes as applicable within fair use. NOTHING HERE IS FOR SALE !

Saturday, 23 February 2019

HITACHI - 42PD8500TV - SERVICE MODE AND ADJUSTMENTS

HITACHI - 42PD8500TV - SERVICE MODE AND ADJUSTMENTS



TO ENTER SERVICE MODE
  • Using the front panel controls with the set turned Off [standby] can activate it. 
  • Press the Sub-Power button, Input-Select button and 'Dn' button at the same time, and hold for more than 5 seconds.
  • Set turns On in adjustment mode with OSD.
To Change the Data values.
  • When the set is in adjustment mode, the cursor Left,Right, Up,Dn and OK buttons on the remote control or the front panel may be used as adjustment keys.
  • Up/Dn buttons are used for selecting adjustment mode.
  • Left/Right buttons are used for changing the data values to the selected modes.
  • OK button is used for confirming the data.
  • After finishing the necessary adjustments, press 'Menu' button.  Adjustment mode is released and the set returns to normal condition.
Memory Initialize Operation.
  • Enter the adjustment mode.
  • Select the 'MEMORY INIT' adjustment code (No. 658) and change the data value from [0] to [1].
  • Activate 'MEMORY INIT' by pressing OK button for more than 3 seconds.
  • Select No.525 and change the data value from [1] to [0].
  • Check that the receiving channel goes to P1.  Unit is set to preset values. 
SELF DIAGNOSIS FUNCTION

This chassis has 2 modes of self diagnosis functions.
  1. PDP panel check mode:  It indicates the one latest records of the PDP panel failure with blinking of the power indication light [LED].
  2. Signal circuit check mode:  It indicates the check result on some points of the signal circuit and the history of them  with On-Screen display [OSD].
PDP Panel self diagnosis function.

This function is for a PDP panel failure with no picture.  To enter the self-diagnosis mode.
  1. The power cord should be connected to AC line, and the main power switch should be turned ON.
  2. Turn the Power Off by the Sub-Power button of the monitor or the remote control.
Procedure
  • Press the Sub-power button and 'Dn' button on the bottom of the monitor at the same time, and keep it for more than 5 seconds after the power turned ON.
  • It generates red blinking series of the power indicator light. 
  • Any operation would cancel the self-diagnosis mode.
Number of red blinks  =>  Presumed failing PWB

1 blink => Logic
2 blinks => X-sustain.
3 blinks => Y-sustain, SDM.
4 blinks => X-Sustain, Y-sustain, SDM, PSU.
5 blinks => ABUS, ADM, PSU.
6 blinks => ADM temperature.
7 blinks => ADM temperature.
8 blinks => all of above mentioned PWB's.

SDM = Scan Driver Module. [SDM is permanantly contacted to glass part]
PSU = Power Supply Unit.
ADM = Address Driver Module.

SIGNAL CIRCUIT SELF DIAGNOSIS FUNCTION

This function is for the feature of the signal circuit, for example the phenomenon below.
"Sometimes Power turns Off automatically, Sometimes picture disappears automatically"

To enter this self diagnosis mode:
  1. The power cord should be connected to AC line and main power switch should be turned On.
  2. Turn the power Off by the sub-power of the monitor or the remote control
Procedure
  • Press the Sub-power button and 'Up' button of the bottom of the monitor at the same time, and keep it for more than 5 seconds after the power is turned On.
  • The monitor will be turned On, and it will display On-Screen display of the self check result and the failure history as below.
  • Any operation would cancel the self-diagnosis mode.
  • The following are the OSD symbols and contents of failure PWB in which failure most probably would be allocated according to number of blinks. The latest error code will be displayed at the bottom left of the screen.
CODE  => PROBLEM  =>  CAUSE

C10 => NO SYNC. [SNOW NOISE]  => NO CONNECTION OF ANTENNA CABLE .  PRESET TUNING IS NOT YET.
H11  => TUNER PROBLEM  => COMMUNICATION ERROR OF [U101]
H15  => COMPOSITE VIDEO SW IC PROBLEM  => COMMUNICATION ERROR OF 1201.
H16  => COMPONENT VIDEO SW IC PROBLEM  => COMMUNICATION ERROR OF 1202.
H31  => COLOR DEMODUATOR IC PROBLEM  => COMMUNICATION ERROR OF 1501.
H32  => SYNC. SEPERATOR IC PROBLEM  => COMMUNICATION ERROR OF 1601.
H33  => 3D Y/C SEPERATOR IC PROBLEM  => COMMUNICATION ERROR OF 1302.
F63  => I2C BUS LATCH PROBLEM  => SCL3/SDA3 LATCHED UP.
To clear the history of failure, make factory reset.
FACTORY RESET
Enter the factory setting mode; press the Sub-Power button, Input Select button and 'Up' button on the bottom of the monitor at the same time.  And keep it for more than 5 seconds after the power is turned On